manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ring Powering
  6. •
  7. Inverter
  8. •
  9. Ring Powering E:Can User manual

Ring Powering E:Can User manual

Other Ring Powering Inverter manuals

Ring Powering E:Can User manual

Ring Powering

Ring Powering E:Can User manual

Ring Powering PowerSourcePro RINV1124 User manual

Ring Powering

Ring Powering PowerSourcePro RINV1124 User manual

Ring Powering PowerSource RINV150 User manual

Ring Powering

Ring Powering PowerSource RINV150 User manual

Popular Inverter manuals by other brands

Omnik New Energy Omniksol-1.5k-TL user manual

Omnik New Energy

Omnik New Energy Omniksol-1.5k-TL user manual

Agilent Technologies 33250A user guide

Agilent Technologies

Agilent Technologies 33250A user guide

4-noks ZR-SWITCH-RC instruction manual

4-noks

4-noks ZR-SWITCH-RC instruction manual

V&T V5 Series user manual

V&T

V&T V5 Series user manual

Hon Turing HT-T-S1000-12 introduction

Hon Turing

Hon Turing HT-T-S1000-12 introduction

Metabo E 140 SP Plus Original operating instructions

Metabo

Metabo E 140 SP Plus Original operating instructions

BARRON EXITRONIX Tucson Micro Series installation instructions

BARRON

BARRON EXITRONIX Tucson Micro Series installation instructions

Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

Baumer

Baumer HUBNER TDP 0,2 Series Mounting and operating instructions

electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

electroil

electroil ITTPD11W-RS-BC Operation and Maintenance Handbook

Silicon Solar TPS555-1230 instruction manual

Silicon Solar

Silicon Solar TPS555-1230 instruction manual

Mission Critical Xantrex Freedom SW-RVC owner's guide

Mission Critical

Mission Critical Xantrex Freedom SW-RVC owner's guide

HP 3312A Operating and service manual

HP

HP 3312A Operating and service manual

Hoymiles HM-500T user manual

Hoymiles

Hoymiles HM-500T user manual

Nitecore SPM10 user manual

Nitecore

Nitecore SPM10 user manual

AEG Protect PV installation manual

AEG

AEG Protect PV installation manual

On Board TruePower Plus 1200MS owner's manual

On Board

On Board TruePower Plus 1200MS owner's manual

Plugreen PGM-200P-230 Installation and operation manual

Plugreen

Plugreen PGM-200P-230 Installation and operation manual

Fourgroup Easy use and Programming Handbook

Fourgroup

Fourgroup Easy use and Programming Handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

12v DC to 230v AC Mains Inverter
RINVC120
User Manual
www.ringautomotive.co.uk
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Troubleshooting guide
PROBLEM: Low output voltage
Possible Cause Suggested Remedy
E:Can inverter is overloaded. Reduce load, not exceeding E:Can maximum rating.
(Consider upgrade, RINV300 to 3000).
Unsure about the appliance rating. Check the data label on the appliance or the instructions. If
this is unsuccessful consult the manufacturer.
PROBLEM: Re-occurring low battery shutdown
Possible Cause Suggested Remedy
Inadequate power or excessive voltage drop. Check connections from battery to E:Can inverter.
Poor battery condition. Replace or charge battery.
PROBLEM: No power output
Possible Cause Suggested Remedy
E:Can inverter in thermal shut down condition. Remove power and load, allow to cool (10 minutes).
Low battery voltage. Charge or replace battery.
E:Can inverter blown fuse. Check / replace the 15Amp fuse in the DC plug.
Vehicle blown fuse (DC socket). Check vehicle handbook to locate relevant fuse.
Poor DC plug connection. Use the DC plug switch to ensure a good connection.
PROBLEM: Liquid ingress
Possible Cause Suggested Remedy
Drinks spillage. Unplug the E:Can and wipe immediately with a dry cloth
(Permanent damage can occur with liquid ingress).
SPECIFICATIONS
PowerSource Model E:Can
Part Number RINVC120
Max. Continuous power (Watts) 120w (5 mins) 100w (4 hours)
Peak Power (Watts) 0.01 Seconds 200w
Standby current (Amps) <0.3A
Waveform Modified Sine Wave
Efficiency* 90%
Input Voltage Range 10v – 15v DC
AC Socket 3 Pin mains 230v AC
Product Dimensions (mm) (D x H) 66 x 160
Pack Dimensions (mm) L x W x H 150 x 100 x 210
Cable length (mm) 450
*Percentage of battery power to mains voltage power.
and eapproved
This inverter should only be used to power Class II (non earthed) products, identified by the symbol:
Can Inverter
Distributed by: Ring Automotive Limited,Volvox House, Gelderd Road, Leeds, England LS12 6NA
+44 (0)113 213 2000 +44 (0)113 231 0266
[email protected].uk www.ringautomotive.co.uk
Can Inverter
Introduction
The Ring E:Can inverter is an electronic device that converts a low voltage 12v DC current from a battery, or
other power supply and provides 230v AC current.
Special attention should be made to CAUTION statements in this user manual.
CAUTION statements identify conditions or practices that could result in damage to your E:Can or to the
equipment you are using with it.
CAUTION
• Do not exceed the maximum input voltage (15 Volts DC).
• Improper use of the E:Can inverter can cause damage to property and possibly harm to the user.
• The E:Can contains no user serviceable parts – Do not open.
Power Supply
The battery or power supply must provide between 10.5 and 14.5 Volts DC (a car battery will usually provide
this) and must be able to provide sufficient current to operate the load (the item you require to power).
The power supply used may be a battery or a regulated DC power supply. In order to find out if your power
supply is large enough, divide the power consumption of the load (in watts) by the voltage (12v in the case
of the E:Can inverter) this will give you the current (in amps) that the power supply must deliver.
EXAMPLE: Load is rated at 48W / 12v = 4 Amps
Connecting to your power supply
Connect the DC plug on the E:Can inverter to the vehicle battery by plugging directly into the 12v DC socket
(cigarette lighter socket). The LED power monitor illuminates green when power is on. The E:Can must only
be used on vehicles where the centre contact of the cigarette lighter socket holder is positive. Ensure the
load requirements are within the specification (max 120w) of the E:Can output. Plug your appliance into the
socket of the E:Can inverter.
Positioning of the E:Can inverter
The following points should be noted:
CAUTION
• The E:Can inverter is not waterproof.
• Take care if adjacent drinks holders contain or have contained liquids.
• The E:Can should be used in a ventilated area.
• Do not obstruct the vent at the rear of the E:Can.
• Do not put the E:Can on or near sources of direct heat or expose to direct sunlight.
• Do not operate the E:Can in or around flammable environments.
• Ensure cables and leads connected to the E:Can do not interfere in the safe operation of the vehicle.
• When not in use store securely in a cool, dry dust free environment.
• Do not leave connected to 12v DC socket unattended.
• Remove from 12v DC socket when not in use as the unit will continue to draw 0.3 Amps stand by current.
• Do not operate continuously for more than 4 hours.
• Do not use the power lead to move or carry the E:Can.
2 3
Operating Tips
NOTE: The PowerSource is not designed to run products
that provide heat, such as hair dryers, heaters and irons.
• Do not handle the E:Can inverter with wet hands or if
it has come into contact with liquid.
• Ensure while driving all accessories powered by the
E:Can inverter are positioned securely.
• Do not use distracting accessories such as mobile
phones whilst driving.
• To ensure optimum performance from the E:Can adjust
the DC plug switch for the correct fit in the vehicles
DC socket.
Maintenance
Cleaning
• Only clean the E:Can inverter using a clean dry cloth.
• Do not use cleaning products.
Fuse Replacement
• The fuse is located in the E:Can DC plug. Unscrew the
end of the DC plug and extract the 15 Amp fuse. Check
the fuse and replace if necessary with an equivalent
15 Amp fuse.
Protective features
Auto shutdown – The E:Can inverter will automatically
shut down if the supply voltage is less than 10v. At
this point the green LED will go out. The inverter will
automatically restart when the input voltage is
above 10v.
Overload protection – The E:Can inverter will automatically shut down if the continuous power draw
exceeds the maximum rating.
Short circuit protection via automatic thermal resetting fuse.
Temperature Protection – If the temperature of the internal heat sink reaches >65˚C the E:Can will shut
down automatically. Remove from power and allow to reset when cool before using.