M-UM006-01 Page 1
TTK 210 Live Fiber ID Test Kit
User Manual and Troubleshooting Guide
7KH77.7HVW.LWLVGHVLJQHGWRDOORZWKHSUHPLVHWHFKQLFLDQWRREWDLQPXOWLSOHÀEHU
test measurements in one kit. Included in the kit are the RP 450-02 Optical Power Meter
DQG/),/LYH)LEHU,GHQWLÀHU$FFHVVRU\7KLVJXLGHZLOOVHUYHDVDEULHIRYHUYLHZRIWKH
IXQFWLRQVRIWKLVNLW
1 2
5 6 7 8
3 4
1. Connector Adapter - Interchangeable
7KH53FRPHVZLWKDPPXQLYHUVDODGDSWHU6HHSDJHRIWKLVGRFXPHQWIRUDGGLWLRQDO
adapter options.
2. Low Battery Indicator
´%$77µZLOODSSHDURQWKH/&'ZKHQWKH&59EDWWHU\QHHGVWREHUHSODFHG
3. 2kHz Tone Indicator
7KH53ZLOOEHHSDQGVKRZ´N+]µRQWKH/&'ZKHQDN+]PRGXODWHGVLJQDOLVUHFRJQL]HG
4. dB/dBm Button
Press this button to toggle between dB and dBm modes. Hold this button down when in dBm
PRGHWRVHWDUHIHUHQFHRQWKH53
5. LCD Screen
7KLVVFUHHQGLVSOD\VWKHPHDVXUHGYDOXHFXUUHQWO\VHOHFWHGZDYHOHQJWKDQGVWDWXVLQGLFDWRUV
6. Measurement Mode Indicator - dB/dBm
dB is a loss measurement. dBm is an absolute power measurement.
7. Wavelength Button
3UHVVWRVZLWFKWKH53EHWZHHQWKHDQGZDYHOHQJWKV
8. Power Button
3UHVVWKLVEXWWRQRQFHWRWXUQWKH53RQ3UHVVRQFHDJDLQWRWXUQWKH53Rර7KH53
LVVHWWRWXUQRරDIWHUPLQXWHV)RUFRQWLQXRXVXVDJHSUHVVDQGKROGWKHSRZHUEXWWRQIRU
seconds when powering on.
RP 450-02 Device Overview
M-UM006-01 Page 2
7RXVHWKH/),DFFHVVRU\ZLWKWKH53UHPRYHWKHDGDSWHURQWKH53
SRZHUPHWHUDQGVOLGHWKHWZRXQLWVWRJHWKHUXQWLOWKH\VQDSÀUPO\LQSODFHVHHSLFWXUHV
DERYH7RVHSDUDWHWKHXQLWVJUDVSWKH/),ÀUPO\ZLWKWKHWKXPEDQGIRUHÀQJHUDQG
SXOOWKHGHYLFHDZD\IURPWKHSRZHUPHWHU
7KH/),XWLOL]HVDPDFUREHQGWHFKQLTXHWRLQGXFHDVPDOODPRXQWRIORVVLQWRWKHÀEHU
7KLVPDFUREHQGZLOOQRWGDPDJHWKHÀEHUQRUSODFHH[FHVVLYHORVVRQWRDÀEHUDFWLYHO\
WUDQVPLWWLQJGDWD7KLVWHFKQLTXHDOORZVWHFKQLFLDQVWRPHDVXUHWKHFRUHSRZHURIDÀEHU
ZLWKRXWKDYLQJWRUHPRYHWKHÀEHUIURPWKHSDWFKSDQHO
7KHÀEHUVKRXOGEHIHGLQWRWKHFKDQQHORQWKH/),LQWKHFRUUHFWGLUHFWLRQVHH
diagram below) and then the trigger on the LFI should be depressed. This will introduce a
PDFUREHQGZKLFKDOORZVDVPDOODPRXQWRIOLJKWWR´OHDNµIURPWKHÀEHULQWRWKHVHQVLWLYH
detector on the RP 450 power meter.
Please note that the RP 450 should be in dBm mode with the correct wavelength selected
WRPHDVXUHFRUUHFWFRUHSRZHUYDOXHV7KHPHDVXUHGVLJQDOYDOXHZLOOEHDSSUR[LPDWHO\
G%OHVVWKDQWKHDFWXDOFRUHYDOXH)RUH[DPSOHLQWKHGLDJUDPEHORZWKHPHDVXUHGFRUH
SRZHUYDOXHLVG%P7KLVHTXDWHVWRDQDFWXDOFRUHSRZHUYDOXHRIG%P
1 - Check Core Power of Fiber with LFI
LFI 110 Device Overview
LFI 110 LFI 110
Attached to RP 450-02
Depress Trigger
on Back of Unit to Obtain
Core Power Measurement
Feed Fiber Into LFI Channel:
Blue Arrow Indicates
Direction of Optical Signal
NOTE:
Fiber cables should be placed in the
ÀEHUFKDQQHORIWKH/),7KHIRDPSDG
EORFNVOLJKWIURPHQWHULQJWKH/),KHDG
and does not provide the appropriate
EHQGLQJIXQFWLRQ
M-UM006-01 Page 3
2 - Active Channel Indication
N+]´7RQHµ,GHQWLÀFDWLRQ
4 - Determining Signal Direction
5 - Adjustment Screw
,IXQVXUHZKHWKHUWKHÀEHUXQGHUWHVWKDVDQDFWLYHRSWLFDOVLJQDOEHLQJWUDQVPLWWHGWKH
77.NLWFDQEHXVHGWRFKHFNIRUDFWLYHFKDQQHODFWLYLW\
The LFI 110/RP 450 combination provides active channel power when the RP 450 power
PHWHUGLVSOD\VDQDEVROXWHSRZHUPHDVXUHPHQWLQG%P,IWKHUHLVQRRSWLFDOSRZHUEHLQJ
WUDQVPLWWHGRQWKHÀEHURULIWKHPHDVXUHGSRZHUOHYHOLVEHORZWKHPHDVXUHPHQWUDQJH
RIWKHSRZHUPHWHUWKH53ZLOOGLVSOD\7KLV´QRVLJQDOµLQGLFDWLRQZLOODOVREH
SUHVHQWZKHQWKH/),WULJJHULVIXOO\GHSUHVVHGZLWKRXWDÀEHULQVHUWHG
7KH53SRZHUPHWHULQFOXGHVDEXLOWLQN+]DXGLEOHDQGYLVXDODODUP7KHN+]´WRQHµ
VLJQDOLVJHQHUDWHGE\DOLJKWVRXUFHFDSDEOHRIPRGXODWLQJWKHODVHUDWN+]$OOGXDODQG
VLQJOHODVHUVRXUFHVPDQXIDFWXUHGE\2'0LQFOXGHWKLVN+]IHDWXUH
7KLVIHDWXUHDOORZVWHFKQLFLDQVWRSODFHDPRGXODWHGN+]VLJQDORQDÀEHUDWHLWKHUHQG
RIWKHQHWZRUNDQGORRNIRUWKHVLJQDODWDQ\LQWHUPHGLDWHVSOLFHHQFORVXUHRUSDWFKSDQHO
:KHQWKH/),LVIXOO\HQJDJHGRQDÀEHUZLWKDN+]WRQHSUHVHQWWKH53SRZHU
PHWHUZLOOSURYLGHDQDXGLEOHEHHSDQGDYLVXDOLQGLFDWLRQWKDWWKH´WRQHµLVSUHVHQW
,IWKHVLJQDOGLUHFWLRQLVXQNQRZQWKH/),53FRPELQDWLRQFDQEHXVHGWRYHULI\
WKHFRUUHFWGLUHFWLRQ7KLVSURFHVVLQYROYHVVLPSO\FKHFNLQJWKHFRUHSRZHURIWKHÀEHUE\
LQVHUWLQJLWLQWRWKHFKDQQHORQWKH/),DQGUHFRUGLQJWKHPHDVXUHGSRZHU7KHQUHYHUVH
WKHGLUHFWLRQRIWKHÀEHULQWKH/),FKDQQHODQGUHFRUGWKDWSRZHUPHDVXUHPHQW:KLFKHYHU
direction indicates a higher power measurement is the correct signal direction.
)RUH[DPSOHLIWZRPHDVXUHPHQWVRIG%PDQGG%PZHUHWDNHQRQWKHVDPHÀEHU
DIWHUVZLWFKLQJWKHGLUHFWLRQLWZRXOGEHFOHDUWKDWWKHGLUHFWLRQDVVRFLDWHGZLWKWKHG%P
measurement would be the correct signal direction.
7KH/),XVHVDQLQWHUQDOVSULQJWROLPLWWKHEHQGSODFHGRQÀEHUFDEOHVZKHQWHVWLQJ
7KLVVSULQJFDQEHDGMXVWHGE\WKHVPDOOVFUHZDWWKHEDVHRIWKHLGHQWLÀHUKHDGVHH
GLDJUDPEHORZ7KHGHIDXOWSRVLWLRQRIWKLVVFUHZZLOOSURYLGHPD[LPXPIXQFWLRQDOLW\RQ
PRVWÀEHUW\SHV)RUVPDOOHUQRQMDFNHWHGÀEHUVPLFURQFRDWHGÀEHUWKHVFUHZFDQ
EHEDFNHGRXWRIWKHKHDGVOLJKWO\WRSURYLGHPRUHÀQHWXQHGEHQGVLQWKHÀEHU7KHEHQG
UDGLXVRIWKH/),FRPSRQHQWVZLOOQHYHUDOORZDQ\ÀEHUWREHEHQWWRDSRLQWZKHUH
PRUHWKDQG%RIORVVLVLQWURGXFHGUHJDUGOHVVRIWKHVFUHZSRVLWLRQ
Flush
Screw Position
Extended
Screw Position
Recommended
Adjustment Screw Positions
Fiber Jacket Screw Position Induced Loss
3mm Flush with Head <1.25dB
2mm Flush with Head <1.00dB
njP PP([WHQGHG <1.00dB
njPFRDWHG PP([WHQGHG <2.00dB
M-UM006-01 Page 4
Power Meter Accessories
'HYLFH6SHFLÀFDWLRQV
Power Meter Adapters
Part Number Description
AC 021 PP$GDSWHU
AC 026 6&$GDSWHU
AC 027 67$GDSWHU
AC 028 )&$GDSWHU
AC 029 /&$GDSWHU
Patch Cord Accessories
Part Number Description
AC 500 606&/&PVLPSOH[
AC 505 606&$6&PVLPSOH[
AC 501 606&6&PVLPSOH[
AC 502 60/&/&PVLPSOH[
AC 600 6&6&VLPSOH[EXONKHDG
536SHFLÀFDWLRQV
Wavelength Range 850nm to 1625nm
Measurement Range RP 450-02: +6 to -60dBm
RP 450-04: +23 to -45dBm
Resolution 0.01dB
Absolute Accuracy +/- 0.25dB
Detector Type RP 450-02: Germanium
53)LOWHUHG,Q*D$V
Optical Interface 8QLYHUVDOPP2WKHUDGDSWHUVDYDLODEOH
7RQH,GHQWLÀFDWLRQ N+],QFRPLQJ6LJQDO$XGLEOH$OHUW
Power On 3XVK%XWWRQ21$XWRRර
Dimensions [[LQ[[FP
Weight R]J
/),6SHFLÀFDWLRQV
1HWZRUN&RQÀJXUDWLRQ 6LQJOH0RGH/RQJ+DXO&2WR&2RU)77[
Core Power Measurement Range
ZLWK53 +23 to -30dBm
,QGXFHG/RVV60) <1.5dB@1550nm
$EVROXWH&RUH3RZHU$FFXUDF\60)H +/- 2dB within measurement range
7RQH,GHQWLÀFDWLRQ N+]LQFRPLQJVLJQDO$XGLEOHDOHUW
Measurement Storage $YDLODEOHZKHQXVHGZLWK53
Dimensions [[LQ[[FP
Weight R]J
ϭϬϲϰĞŶƚƌĞZĚ
KĂŬůĞŝŐŚ^ŽƵƚŚsŝĐϯϭϲϳ
ƵƐƚƌĂůŝĂ
ϭϯϬϬ ϯϲϬϮϱϭ
ŝŶĨŽΛǀŝĐŽŵĐŽŵĂƵ
ǁǁǁǀŝĐŽŵĐŽŵĂƵ
'ƌĚ&ůŽŽƌϲϬ'ƌĂĨƚŽŶZŽĂĚ
ƵĐŬůĂŶĚϭϬϭϬ
EĞǁĞĂůĂŶĚ
нϲϰϵϯϳϵϰϱϵϲ
ŝŶĨŽΛǀŝĐŽŵĐŽŶnj
ǁǁǁǀŝĐŽŵĐŽŶnj
For More Information: sŝĐŽŵAustralia sŝĐŽŵEĞǁĞĂůĂŶĚ

Other Ripley Test Equipment manuals

Ripley MILLER VIS500 User manual

Ripley

Ripley MILLER VIS500 User manual

Ripley ODM VIS 300C User manual

Ripley

Ripley ODM VIS 300C User manual

Ripley MILLER DLS 650 User manual

Ripley

Ripley MILLER DLS 650 User manual

Ripley Miller DLS350 User manual

Ripley

Ripley Miller DLS350 User manual

Ripley ODM RP 460 User manual

Ripley

Ripley ODM RP 460 User manual

Ripley Miller DLS355 User manual

Ripley

Ripley Miller DLS355 User manual

Popular Test Equipment manuals by other brands

Fluke LinkRunner AT 1000 user manual

Fluke

Fluke LinkRunner AT 1000 user manual

Tsuruga 8525 instruction manual

Tsuruga

Tsuruga 8525 instruction manual

Aegis CZ20252 user guide

Aegis

Aegis CZ20252 user guide

Softing WireXpert Cat6A+Adapters user manual

Softing

Softing WireXpert Cat6A+Adapters user manual

Dawson DET 301 user manual

Dawson

Dawson DET 301 user manual

Ralston Instruments Nitropack Operation manual

Ralston Instruments

Ralston Instruments Nitropack Operation manual

NoiseKen GT-30R instruction manual

NoiseKen

NoiseKen GT-30R instruction manual

MULTILANE AT4039EML user guide

MULTILANE

MULTILANE AT4039EML user guide

MARTINDALE ET5 instruction manual

MARTINDALE

MARTINDALE ET5 instruction manual

MotoBatt MBPro user manual

MotoBatt

MotoBatt MBPro user manual

Instron 5940 Operator's guide

Instron

Instron 5940 Operator's guide

T3 Innovation Coax Clarifier TCC200 user manual

T3 Innovation

T3 Innovation Coax Clarifier TCC200 user manual

Facom DF.16 instruction manual

Facom

Facom DF.16 instruction manual

Delta Regis DRTQ Series user manual

Delta Regis

Delta Regis DRTQ Series user manual

Mocon AMETEK Dansensor Lippke 5000 user guide

Mocon

Mocon AMETEK Dansensor Lippke 5000 user guide

Alcovisor BAC-100 instruction manual

Alcovisor

Alcovisor BAC-100 instruction manual

Tektronix P6960 manual

Tektronix

Tektronix P6960 manual

Tektronix 3B4 instruction manual

Tektronix

Tektronix 3B4 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.