Installation Instructions
The rangehood must be installed at the correct distance above the cooktop
(650mm minimum, 750mm recommended maximum).
Measure up from the top of the cooktop the desired height & draw a horizontal line.
From this line, measure up 350mm (RHWC60X, RHWC90X, RHWC60TB & RHWC90TB) or 360mm
(RHWC60TG & RHWC90TG) and draw a second horizontal line for the main mounting screws.
Mark the centre point on this line and mark the screw positions 120mm either side.
For a brick or concrete wall, drill in the two holes ~40mm deep.
Fit the wall plugs and screw in the two supplied 40mm screws (leaving the head ~5mm proud of the
wall).
Lift the rangehood onto the screws and check for strength.
Mark up the position of the single stabilising screw (RHWC60TG & RHWC90TG), or two stabilising screws
(RHWC60X, RHWC90X, RHWC60TB & RHWC90TB) and remove the rangehood from the wall mounting
screws.
Drill the hole(s) and add the wall plug(s).
Remount the rangehood onto the wall and use the extra 40mm screw(s) to attach the bottom of the
rangehood to the wall.
Tighten all screws fully.
Fit the ducting to the outlet and secure in place with the supplied 4mm screws.
*Flexible or semi-rigid ducting pipe can be used, however, Robinhood strongly recommend the use of
semi-rigid ducting wherever is possible. We offer a full range of semi-rigid ducting solutions under the
Uniduct brand, for more information please visit www.robinhood.co.nz
Lift the inner chimney to the ceiling and mark the position of the edges (close to the ceiling).
Lower the chimney and place the chimney bracket up to the ceiling centred between the marks.
Mark the centre of the slots, drill the two holes, add the wall plugs and attach the bracket to the wall.
Place the power plug close to the socket, extend the ducting pipe out, raise the chimney to the bracket
and attach with the two 7mm screws.
Check that the rangehood is secured.
Clip the oil cup into the slot underneath the motor. (The oil cup can be found in User Manual’s bag).
Refit the filters and connect to the power supply.
If the wall is not brick or concrete, an alternate mounting method must be determined.
Note: if the air is recirculated back into the room, charcoal filters must be used (part number CARBONFTLDEEU:
check availability before installation is commenced).