www.rohlhome.com
Consult your local ROHL showroom for additional information and specifications. For complete warranty details and a list of showrooms, go to www.rohlhome.com.
INSTALLATION INSTRUCTIONS
Congratulations on the purchase of your Perrin & Rowe bathroom tapware. Correctly installed and with sensible
care, this product will give you many years of trouble free service.
The Transitional Bathroom Collection
Installation & User Guide
IMPORTANT INFORMATION
Beforeyou proceed... Werecommend you engage theservices of a registered plumber to install this
product.
In addition to theguidebelow it is essential that thewritten information overleaf is carefully read and
understood.
PreparationCheck Box for Installer
Please check that the contents of your Perrin & Rowe Shower Trim set are complete. Please check before you
install the product that there is no damage to the contents as we cannot accept any responsibility after
installation.
1
PreparationCheck Box for Installer - Wall Mounted
Flush the plumbing system before
installing the bathroom product.
Wall Plate
Lever Assembly
2.5AF Wall Plate
Fixing Screws
Prepare cavity to
sizes shown below.
We recommend that the hot and cold supplies
should have conveniently placed isolating
valves to accomodate any servicing
requirements.
2
Trim
Front view of
cavity with
plaster
guard
removed
Side view of
cavity
Fixing Plate
U.5886TX
O
165mm
O
(6 . 1/2")
3.1
2" MIN
4.1
8" MAX
67mm MIN
90mm MAX
3
CAUTION: Protect finish on
TRIM, PLATE & LEVER or X-TOP
• When finished tiling the wall, remove the plaster guard
(A) by removing x2 screws, and turn off water supply.
• Fit fixing plate onto in-wall rough.
• Ensure the 2 alignment ID marks on both Splined
Spindle and Valve Cartridge are aligned with
each other before you attempt to place the Trim in
position(see diagram B).
• Align holes on face plate with rough in-wall plate and
push on Trim assembly (C), ensuring the fit is secure by
rotating the Lever against the override stop.
• Once the Trim assembly is mounted into correct
aligned position, use Face Plate fixing screws (D) to
secure face plate to tiled wall. Use a 2.5AF Allen Key,
taking care not to damage finish.
At this stage ENSURE the ROUGH is
correctly installed (In-Wall) - Valve
Body: U.5585R (pictured above &
left), before attempting this Trim
installation.
IN-WALL
U.5585R
D
OPERATION
• The temperature is adjusted by rotating the Lever/X-Top either left or right.
• Rotate the seperate flow control lever anti-clockwise a quarter turn to
activate the shower flow.
• The thermostatic cartridge has been set to give a temperature of 100ºF
(38ºC), this is when the temperature control lever is in the vertical position.
• A hotter shower can be achieved by pulling out the temperature override
mechanism (see diagram) and rotating the lever anti-clockwise, up to
118ºF (48ºC).
•Anti-Scald: The Thermo cartridge will automatically shut down
completely on failure of either the hot or cold supply. This is to safe guard
children or the elderly. Cartridge will reactivate when failure has been
corrected.
INSTALLTRIM
A
B
SPINDLE ID
MARK
VALVE ID
MARK
C
ROUGH IN-WALL
PLATE
FIXING PLATE