Advanced Communication Module - Installation Guide
33
Mounting & Connections
The ACM may be mounted onto the ProSYS main board using the
provided plastic spacers or in a special accessory box (P/N:
RP128B300UKA).
NOTES:
1. Handle the ACM module with care when installing it.
2. When attaching an ACM box to the wall, it is recommended to use
Ø4.2mm, 32mm length screws (DIN 7981 4.2X32 ZP).
3.
IMPORTANT:
1. Disconnect all power sources from the ProSYS panel prior to servicing
the ACM or connecting it to the panel BUS!
2.
Before connecting the ACM, calculate and check that the power drawn
by the ACM, together with all accessories connected to the ProSYS, is
within the power supply current range! Add a power supply module if
required.
1. Mount the ProSYS main board inside the BOX as described in the
Installer manual 5IN128IM.
2. Attach the 4 plastic spacers using the provided plastic screws to
the ProSYS main holes shown in Figure 2.
3. Connect 2 plastic support spacers to the ACM board (using plastic
screws) as shown in Figure 2.
4. Align the ACM mounting holes with the spacers on the ProSYS
panel and snap into place.
5. Connect the provided 4-wire cable from the ACM BUS connector
to the ProSYS BUS connector.
6. Connect the ACM to the Ethernet by plugging an appropriate
Ethernet cable plug into the RG-45 connector on the ACM (see
Figure 2).
NOTES:
In order to meet EMC requirements, it is recommended to use a ferrite
bead manufactured by Fair-Rite p/n 0446167281 with one turn at the
Ethernet cable close to the connector inside the metal box.