7
During the installation of the cooker hood, always wear protective handgloves to prevent
injuries.
The manufacturer strongly advises against the use of reducers or pipes with different diameter
to the hood outlet pipe.
The end part of the pipe, on the outside of the hole on the wall, must be of such a shape to
avoid rain, gusts of wind or other foreign bodies getting into the pipe.
AIRFLOW ADJUSTMENT
Forced ventilation:
■Rotate the screw counterclockwise 360° (image 10 point 1).
■Move the plate (image 10 point 2) in the desired position corresponding to the diagram,
shown in the graphic of image F.
■Rotate the screw clockwise until it is fixed (image 10 point 3).
■Measure the Pm pressure to check that the value of the desired forced ventilation is
obtained with reference to diagram of image F.
Basic ventilation (if recommended):
■Remove the screw (image 11 point 1).
■Remove the existing valve plate (image 11 point 2).
■Insert the supplied plate with the curved side (image 12 point 3).
■Move the plate with the curved side (image 13 point 4) in the desired position
corresponding to the desired value shown in the graphic of the image G.
■Insert the screw rotating it clockwise until it is fixed. (image 13 point 5)
■Measure the Pm pressure to check that the wished basic ventilation value is obtained with
reference to diagram of image G.
BEFORE ELECTRICAL INSTALLATION
Before connection you must:
■check that the electrical data indicated are in conformity with the main voltage and
frequency values of the building where the hood is to be installed;
■check that the building is fitted with electric safety systems to protect against short circuits
and electric shock systems, according to the laws in force;
■install an electric socket (or connection point) with a bipolar switch, which has contacts with
an opening of at least 3 mms;
■if it is wished to install the hood with a plug, it is necessary that you have access to the
plug;
■always turn off the main voltage supply by means of the bipolar switch before connecting
and switch on again only when connections have been completed, tested and are safe.
ELECTRICAL CONNECTION
WARNING
The electrical connection can only be carried out by qualified professional personnel, using
standard material and standard installation methods. The manufacturer declines any
responsibility for installations carried out by unskilled persons and for installations which are