Specifications
Power Supply : DC 9V
Power Supply Range : DC 4.5 – 12V
Standby Current : < 15 mA
Active Current : < 20 mA
Battery Low Voltage : 5.2 +/- 0.2 V
Working Temperature : -25 1C ~ + 60 1C
Working Humidity : < 95%
Storage Temperature : - 45 1C ~ + 85 1C
Manager/User Code Length : 6 Digits
1000-SERIES
ELECTRONIC COMBINATION
SAFE LOCK
OPERATING INSTRUCTIONS
C
CH
HA
AN
NG
GI
IN
NG
G
T
TH
HE
E
B
BA
AT
TT
TE
ER
RY
Y
This unit runs on a 9V alkaline battery. It is
recommended that either ‘Duracell’ or ‘Energizer’
brands be used.
To change the battery, please refer to the diagram
below.
•Simply slide the entry pad housing up and
carefully pull it away from the mounting surface
to expose the battery compartment.
•The battery connector is easily removed by
unclipping it from the terminals on top of the
battery. Care must be taken to ensure that the
wires leading from the battery connector to the
entry pad are not pulled out from the housing.
•Once the battery has been changed, carefully
position the entry pad back over the mounting
screws and slide the entry pad back into
position. Ensure there are no wires or cables
trapped between the entry pad and the safe
door.
Distributor :-
ROSS
A.B.N. 23 609 454 458
K.J.ROSS SECURITY LOCKS
PTY.LTD.
Lock Manufacturer
i
Specialist in Safe & Vault Locks
29 Henderson Road, Knoxfield, Victoria 3180, Australia.
Telephone :- + 61 3 9763 1796 Fax :- + 61 3 9763 4223
Email :- [email protected] Web :- www.rosslocks.com.au
AUSTRALIAN MADE
M
MA
AN
NA
AG
GE
ER
R
S
ST
TA
AR
RT
TU
UP
P
I
IN
NS
ST
TR
RU
UC
CT
TI
IO
ON
NS
S
T
TO
O
O
OP
PE
EN
N
F
FO
OR
R
T
TH
HE
E
F
FI
IR
RS
ST
T
T
TI
IM
ME
E
Using the factory set manager code –
•
Enter ( 1 2 3 4 5 6 ) 2 beeps sound.
•
The handle can now be turned to open the safe door.
T
TO
O
C
CH
HA
AN
NG
GE
E
T
TH
HE
E
M
MA
AN
NA
AG
GE
ER
R
C
CO
OD
DE
E
Always perform the following instructions
with safe door open.
•
Enter ( 0 0 0 0 0 0 ) 2 beeps sound.
•
Enter the factory set manager code
( 1 2 3 4 5 6 ) 2 beeps sound.
•
Enter the new 6 digit manager code. 1 beep sounds.
•
To verify, re-enter the same manager code. 1 beep
sounds.
•
Enter the new manager code to verify the new code
has been accepted. 2 beeps sound.
T
TO
O
A
AD
DD
D
T
TH
HE
E
U
US
SE
ER
R
C
CO
OD
DE
E
F
FO
OR
R
T
TH
HE
E
F
FI
IR
RS
ST
T
T
TI
IM
ME
E
•
Enter the manager code, and on the last digit of the
code, hold the button down until 2 set of 2 beeps
are sounded.
•
Enter ( 1 ) 2 beeps sound.
•
Enter the 6 digit user code. 1 beep sounds.
•
To verify, re-enter the same user code. 1 beep
sounds.
•
Enter the new user code to verify the new code has
been accepted. 2 beeps sound.
M
MA
AN
NA
AG
GE
ER
R
O
OP
PE
ER
RA
AT
TI
IO
ON
NA
AL
L
I
IN
NS
ST
TR
RU
UC
CT
TI
IO
ON
NS
S
T
TO
O
C
CH
HA
AN
NG
GE
E
T
TH
HE
E
U
US
SE
ER
R
C
CO
OD
DE
E
Always perform the following instructions with
safe door open.
•
Enter ( 0 0 0 0 0 0 ) 2 beeps sound.
•
Enter the user code. 2 beeps sound.
•
Enter the new 6 digit user code. 1 beep sounds.
•
To verify, re-enter the same user code. 1 beep sounds.
•
Enter the new user code to verify the new code has
been accepted. 2 beeps sound.
T
TO
O
D
DI
IS
SA
AB
BL
LE
E
T
TH
HE
E
U
US
SE
ER
R
C
CO
OD
DE
E
•
Enter the manager code, and on the last digit of the
code, hold the button down until 2 set of 2 beeps are
sounded.
•
Enter ( 2 ) 2 beeps sound.
•
Enter the user code to verify this code has been
disabled.
T
TO
O
E
EN
NA
AB
BL
LE
E
T
TH
HE
E
U
US
SE
ER
R
C
CO
OD
DE
E
•
Enter the manager code, and on the last digit of the
code, hold the button down until 2 set of 2 beeps are
sounded.
•
Enter ( 1 ) 2 beeps sound.
•
Enter the user code to verify this code has been
enabled.
T
TO
O
D
DE
EL
LE
ET
TE
E
T
TH
HE
E
U
US
SE
ER
R
C
CO
OD
DE
E
•
Enter the manager code, and on the last digit of the
code, hold the button down until 2 set of 2 beeps are
sounded.
•
Enter ( 3 ) 2 beeps sound.
•
Enter the user code to verify this code has been
deleted.
•
To re-enter the user code, follow the procedure, “ To
add the user code for the first time”.
O
OP
PE
ER
RA
AT
TI
IO
ON
NA
AL
L
F
FE
EA
AT
TU
UR
RE
ES
S
S
ST
TA
AN
ND
DB
BY
Y
M
MO
OD
DE
E
•There is a time limit of 15 seconds allocated to
complete an instruction.
•nd to indicated you will need to2 beeps will sou
re-start the instruction again.
W
WR
RO
ON
NG
G
E
EN
NT
TR
RY
Y
P
PE
EN
NA
AL
LT
TY
Y
•If 4 consecutive invalid codes have been entered,
a 5 minute delay period will be activated.
•lA beep, in intervals of 5 seconds, will sound unti
the time delay period has expired.
A
AU
UT
TO
OM
MA
AT
TI
IC
C
R
RE
E-
-L
LO
OC
CK
K•A re-lock will occur within 4 seconds.
L
LO
OW
W
B
BA
AT
TT
TE
ER
RY
Y
I
IN
ND
DI
IC
CA
AT
TO
OR
R
•If during the unlock cycle, a repeated beeping
sound is detected, the battery is low and needs to
be replaced.
•It is recommended that either “Energizer” or
“Duracell” brands be used.
•To change the battery, please refer to the
procedure, “Changing the battery”.
U
US
SE
ER
R
O
OP
PE
ER
RA
AT
TI
IO
ON
NA
AL
L
I
IN
NS
ST
TR
RU
UC
CT
TI
IO
ON
NS
S
C
CH
HA
AN
NG
GE
E
T
TH
HE
E
U
US
SE
ER
R
C
CO
OD
DE
E
Always perform the following instructions with
safe door open.
•
Enter ( 0 0 0 0 0 0 ) 2 beeps sound.
•
Enter the user code. 2 beeps sound.
•
Enter the new 6 digit user code. 1 beep sounds.
•
To verify, re-enter the same user code. 1 beep sounds.
•
Enter the new user code to verify the new code has
been accepted. 2 beeps sound.

Other Ross Lock manuals

Ross 1000-Series User manual

Ross

Ross 1000-Series User manual

Ross 1000-SERIES User manual

Ross

Ross 1000-SERIES User manual

Ross 1000 Series User manual

Ross

Ross 1000 Series User manual

Popular Lock manuals by other brands

Würth A302 Series Assembly instruction

Würth

Würth A302 Series Assembly instruction

Nath Designs ResLock SHENZHEN NATHANTECHNOLOGY installation instructions

Nath Designs

Nath Designs ResLock SHENZHEN NATHANTECHNOLOGY installation instructions

Allegion AD Series manual

Allegion

Allegion AD Series manual

Sargent ASSA ABLOY Profile Series installation instructions

Sargent

Sargent ASSA ABLOY Profile Series installation instructions

Schlage B260 Series installation instructions

Schlage

Schlage B260 Series installation instructions

L&F Euro-Locks 2800 User instructions

L&F

L&F Euro-Locks 2800 User instructions

Gianni Industries GEM EM-NH2300 specification

Gianni Industries

Gianni Industries GEM EM-NH2300 specification

StarTech.com LTLOCK4D quick start guide

StarTech.com

StarTech.com LTLOCK4D quick start guide

Major Manufacturing HIT-66-230 instructions

Major Manufacturing

Major Manufacturing HIT-66-230 instructions

Stock Loks C8747 instruction sheet

Stock Loks

Stock Loks C8747 instruction sheet

Rottner EM2020 User instructions

Rottner

Rottner EM2020 User instructions

Best Wi-Q Technology EXQ Series installation instructions

Best

Best Wi-Q Technology EXQ Series installation instructions

BURG-WACHTER SecuTronic operating instructions

BURG-WACHTER

BURG-WACHTER SecuTronic operating instructions

Sewosy K1000 user manual

Sewosy

Sewosy K1000 user manual

COMPX MFWSG29000 Dimensional drawing

COMPX

COMPX MFWSG29000 Dimensional drawing

M-LOCKS T6530 Technical manual

M-LOCKS

M-LOCKS T6530 Technical manual

KOOGEEK L3 quick start guide

KOOGEEK

KOOGEEK L3 quick start guide

Kaba PowerPlex 2000 Series quick start guide

Kaba

Kaba PowerPlex 2000 Series quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.