www.rm-suttner.com
1, Ver. 11.2017
User Manual ST-73.1 Foam Lance
Artikel-Nr.: 200 073 ...
General safety notes
Info
Intended use
Description
The ST-73.1 is for foaming suitable foaming agents. The ST-73.1 foam lance is
ttedwithaninterchangeableinjectornozzleandafoamingpad.Byturningan
adjustablegriphandletheconcentrationoffoamingagentinthewatercanbe
adjusted.
Availableareanoptional1-litreintakecontainer(ProductCode020073513)
or2-litreintakecontainer(ProductCode020073520).
▪ Toguaranteesafeoperationtheinjectorunitmayonlybe
usedinaccordancewiththeseOperatingInstructions.
▪ KeeptheseOperatingInstructionsinasafeplaceforlater
reference.
▪ Pleasealsoobservethesafetyinstructionsforthedetergent
andifapplicableofthehighpressurecleanermanufacturer.
▪ Donotmixdetergentsonewiththeother.
▪ Wearsuitableprotectiveclothingandgloveswhenworking.
▪ Neverdirectthehigh-pressurejetatpersonsorotherlivingcreatures.
▪ Readthesafetydatasheetsandobservethecorrespondingsafetyandhandlingregulations.
▪ TheST-73.1foamlanceisusedforadmixingfoamingagenttowater,subsequentfoamingandthenfoam
application.
▪ OnlyPressureEquipmentDirective(PED)Group2liquidsmaybeusedasmedia.Incaseofdoubtcontactthe
equipmentmanufacturer.
▪ The housing of the ST-73.1 was made of PP-GF40, the ST-73.1 is not suitable for forming with strong
acids (pH-value <4), for example formic acid, hydrofl uoric acid etc.
▪ Theunitmayonlybeusedwithasuitablepressuregenerator.
▪ Theunitisnotdesignedforusewithpersons(childrenincluded)withrestrictedsensoryandmentalcapabilitiesdue
tolackofexperienceand/orlackofknowledgeunlesstheyaresupervisedbyapersonresponsiblefortheirsafety
oriftheyhavereceivedinstructionfromthatpersoninuseoftheequipment.
▪ Ingeneralchildrenareforbiddentousethisequipment.
Flush the foam lance internally and externally with clear water after use. Otherwise there is the risk that that
substances adhering accumulate and adversely affect proper functioning of the foam lance.
Flushthefoamlanceinternallyandexternallywithclearwaterafteruse.Otherwisethereistheriskthatthatsubstances
adheringaccumulateandadverselyaffectproperfunctioningofthefoamlance,otherwisethereistheriskthatthat
substancesadheringaccumulateandadverselyaffectproperfunctioningofthefoamlance.
Operation
Byturningtheadjustablegriponthehandlethequantityoffoamingagentconcen-
tratecanbeadjusted.IntotaltheST-73.1hasvedetentstagesforxedpositioning
thedosagesettingandthesearegentlynoticeableonturningtheadjustablegrip.
In Position I = lowest concentration
In Position IIIII = highest concentration
Snap-instage
Adjustment
gpopen
close
Mark
Detail
The ST-73.1 is for foaming suitable foaming agents. The ST-73.1 foam lance is
ttedwithaninterchangeableinjectornozzleandafoamingpad.Byturningan
▪ Neverdirectthehigh-pressurejetatpersonsorotherlivingcreatures.