WARNING: For your protection do not connect the
Laminator to electrical power or attempt to
operate until you read these instructions
completely. Keep these instructions in a
convenient location for future reference. To
guard against injury, the following basic safety
precautions must be observed in the set-up
and use of the laminator.
Set-up
1. Connect power cord to appropriate power source.
2. Push the switch on to ÔWARMÕ.
3. Select appropriate temperature for both gauge of pouch you
are using and the type of material you are laminating (see
chart for guidelines).
Approximate temperature setting guidelines for pouches*
* Temperature setting will vary due to the finish, chemistry
and heat absorption properties of the materials you are
laminating. Use this chart as a guideline only and adjust
temperature as necessary. If pouch is cloudy the first pass
through the machine, adjust temperature setting higher and
run through again. If warping occurs, reduce temperature -
run additional pieces at lower setting once machine has
cooled.
Operation
1. Once the ÔREADYÕ light activates to indicate machine is at
operating temperature, switch machine on to ÔRUNÕ.
2. Place the item to be laminated into a laminating pouch,
centring it within the pouch (see figure 1).
3. Insert the pouch containing the item into a carrier which is
provided with each carton of pouches. Position the pouch
toward the centre of the carrier with the sealed edge facing
the inside folded edge of the carrier (see figure 1). Please
handle carriers carefully so they may be re-used.
4. Insert the folded edge of the carrier STRAIGHT into the
front of the laminator until you feel the roller pick up the
carrier.
5. Remove the carrier from the rear of the laminator after it
has stopped moving. Leave the pouch within the carrier
and place on a flat surface for a few seconds until cool
before removing it.
6. If you adjust the temperature during a lamination job, allow
appropriate time for the machine to reach desired
temperature.
Guidelines
Wait a few minutes then verify the
temperature with the ÔREADYÕ
light.
Wait at least 10 minutes
7. When you are finished laminating, switch the machine to
ÔOFFÕ.
Note: The laminator features an AUTO cut-off to prevent
overheating. If this should occur, allow unit to cool
before continuing your lamination application. If you are
laminating using 500 micron pouches please be aware
Auto cut-off will occur after 15 minutes. In the event,
allow unit to cool before you continue with your
lamination application.
General safeguards
Use the laminator only for its intended purpose of laminating
documents up to 292mm wide.
Do not place anything in the throat opening of the machine
other than pouch carriers with appropriate pouches inside.
Place unit on a secure, stable work area to prevent the
machine falling and possibly causing personal injury and/or
damage to the unit.
Turn unit off when not in use.
Electrical safeguards
The laminator must be connected to a supply voltage
corresponding to the electrical rating of the machine as
indicated on the serial label located on the base.
Unplug the laminator before moving it, or when it is not in
use for an extended period of time.
Compact A3 Laminator
Stock No. 184-5236
Pouch
(total thickness)
Heat setting Heat setting Heat setting
70gsm paper 80gsm paper 135gsm
artpaper
(colour printed)
A3
150 micron 3.0 3.0 3.0
250 micron 3.5 3.5 3.5
360 micron 4.0 4.0 4.0
500 micron 4.0 4.0 4.5
A4
150 micron 2.5 3.0 3.0
250 micron 3.5 3.5 3.5
360 micron 4.0 4.0 4.0
500 micron 4.0 4.0 4.5
ID
250 micron 3.5 3.5 3.5
360 micron 4.0 4.0 4.0
500 micron 4.5 4.5 4.5
NB: Not recommended for use on photographs
* Raise temperature
to a higher setting
* Reduce temperature
to a lower setting
Figure 1.
¥
¥
¥
¥
¥
¥
Do not operate with a damaged power supply cord or plug.
Do not overload outlets beyond their capacity as this can
result in fire or electrical shock.
Do not alter attachment plug. Plug is configured for
appropriate electrical supply.
The unit is intended for indoor use only.
Service
Do not attempt to service or repair the laminator yourself
Unplug the unit and contact RS Servicepoint for any
required repairs.
Cleaning
Wipe exterior only with a damp cloth. Do not use detergents
or solvents.
Technical specification
Dimensions: H90 x W452 x D205mm
Weight: 4.5kg
Electrical: 240V, 50Hz
Accessories
Item RS stock no.
A4 Pouch 150 Micron 737-241
A4 Pouch 250 Micron 737-257
A3 Pouch 150 Micron 737-263
A3 Pouch 250 Micron 737-279
Badge pouch 737-285
Luggage pouch 737-291
Lapel clip 737-314
Luggage straps 737-320
1D Neckchains 769-838
Slot punch 737-308
RS Components Issued July 1995 10021
¥
¥
¥
¥
¥

This manual suits for next models

1

Popular Laminator manuals by other brands

GBC HeatSeal H400 instruction manual

GBC

GBC HeatSeal H400 instruction manual

UNITED OFFICE ULG 350 A1 operating instructions

UNITED OFFICE

UNITED OFFICE ULG 350 A1 operating instructions

CUTWORX Matrix Series user manual

CUTWORX

CUTWORX Matrix Series user manual

Eastsign P Series user manual

Eastsign

Eastsign P Series user manual

ACCO Brands GBS Academy+ quick start guide

ACCO Brands

ACCO Brands GBS Academy+ quick start guide

YMJ Portable Lamination Machine Installation, operation & maintenance manual

YMJ

YMJ Portable Lamination Machine Installation, operation & maintenance manual

D&K Minikote owner's manual

D&K

D&K Minikote owner's manual

ibico Pouchman 4PQ instruction manual

ibico

ibico Pouchman 4PQ instruction manual

GBC Fusion 5000L Start here

GBC

GBC Fusion 5000L Start here

Fellowes Jupiter 125 instructions

Fellowes

Fellowes Jupiter 125 instructions

Tamerica TCC-1655HC operating manual

Tamerica

Tamerica TCC-1655HC operating manual

Royal Sovereign RSC-1050CL owner's manual

Royal Sovereign

Royal Sovereign RSC-1050CL owner's manual

texet LMA3-V user manual

texet

texet LMA3-V user manual

Royal Sovereign RSC-1650C manual

Royal Sovereign

Royal Sovereign RSC-1650C manual

Aurora LM-920H Specifications

Aurora

Aurora LM-920H Specifications

GBC FUSION 3000L Start here

GBC

GBC FUSION 3000L Start here

Exibel LA4G manual

Exibel

Exibel LA4G manual

ChemInstruments HL-200 operating instructions

ChemInstruments

ChemInstruments HL-200 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.