4
Test
Turn the light-control knob clockwise to the maximum (SUN), turn time knob anti-clockwise to the minimum;
Switch on power, the controlled load should not work, under the no induction signal condition, the load
should stop work within 5-30sec;
Make it sense again 5-10sec later since the first is out, the load should work, the load should stop working
within 5-20sec;
Turn LUX knob to minimum anti-clockwise, if you test it when the light-control is more than 3LUX, the
induction load would not work after the load stops working; the load should work if you cover the detection
window with opaque object (towel etc),it would be regular the load stops to work within 5-15sec under no
induction signal condition.
Note:
1. Should be installed by electrician or experienced person.
2. Avoid installing it on the unrest object.
3. There should be no hindrance and moving objects in front of the detection windows to effect detection.
4. Avoid installing it near air temperature alteration zones such as air condition, central heating, etc.
5. Considering your safety, please do not open the cover when you find the hitch after installation;
6. If there is difference between instruction and the function the product has, please give priority to product and
sorry not to inform you additionally.
Some problem and solved way
1. The load do not work:
a: Please check if the connection-wiring of power and load is correct;
b: Please check if the load is good ;
c: Please check if the working light set correspond to light-control.
2. The sensitivity is poor: