RS 796-2015 User manual

• Single gang PIR switch
• Replaces a standard light
switch or dimmer
• Turns off automatically
• Turns on automatically
• Security mode
• Switches all lighting, heating
and ventilation loads up to 10A
GIPDC/B
User Guide
CP Electronics
Brent Crescent
London
NW10 7XR
T: + 44 (0)333 900 0671
F: + 44 (0)333 900 0674
www.cpelectronics.co.uk
enquiry@cpelectronics.co.uk

installation
Location
It is important to locate the detector
so that any occupants fall within the
detection zone shown on the diagram.
Do not block the sensor with a door or
other object.
Do not install above a radiator or other
heat source.
Avoid direct sunlight entering the sensor.
2
✔✘
Detection zone
This product should be installed in
accordance with the current IEE wiring
regulations. If in doubt consult a qualified
electrician.
Use the extender if there is less than
25mm free space.
REMEMBER – put the wires through
the extender before connecting.
Compatible with all BS4662 dimensions
back boxes.
Remove top and bottom lugs if fitted.
25mm
Do not overtighten
5M
4.5M

3
1 way switching
If the lights are controlled from one
location only, wire as in the diagram.
2 way switching
If more than one detector is required to switch the lighting (e.g. at the top and bottom of a
staircase) they can be wired in parallel, as in the diagram.
wiring
May have red
or brown sleeve
May have red or
brown sleeve
Com L1
Neutral Black or Blue
Live Red or Brown
Earth Yellow Green
Strapper Yellow or Grey

4
time setting
on
off
battery
Short press – lights on
Press for more than 5 seconds to activate (see
Activate section).
Short press – lights off
The lights will turn off whilst the area is occupied.
The unit will reset to automatic operation after a
period of time.
Press for more than 5 seconds to de-activate (see
Activate section).
controls and basic operation
daylight
setting
battery
indicator
PIR lens
toggle
switches
Remove front cover
Use a flathead screwdriver or similar
to gently prise off the cover and replace
with new one by snapping on to switch.
ON
1 2
TOP

5
setup and suggested settings
Manual on (use on button):
Auto off (when nobody in the
room, after time period).
Auto on (when somebody
enters room):
Auto off (when nobody in the
room, after time period).
Security mode activated.
See ‘Security Mode’ section
(pg 6).
Security mode deactivated.
GIPDC GIPDT
Quick Start Guide
installation and wiring
suggested settings CORRIDOR
This product should be installed
in accordance with the current
IEE wiring regulations.
If in doubt consult a qualified
electrician.
•
Auto on—turns on when someone enters the corridor
•
Auto off—turns off when nobody in the room for 20 minutes
•
Lux—only turns on when there is little or no natural light
suggested settings BEDROOM AREA operation
Shallow back box?
Different wiring colours?
2 way wiring?
Refer to main datasheet.
www.cpelectronics.co.uk
%WD267 Issue 1
Remove top
and bottom
lugs if fitted
Do not
overtighten
Live
supply
Lamps
May have
red or
brown
sleeve
•
Manual on—turns on when top button pressed
•
Auto off—turns off when nobody in the room for 10 minutes
2
Com L1
Short press—lights on
Short press—lights off
The lights will turn off whilst the area is occupied.
The unit will reset to automatic operation after a
period of time.
•
Before using, the unit needs to be activated.
•
Press and hold the top button for more than 5 seconds.
The red LED will flash to indicate that has activated and
the unit will now operate.
activate
GIPDC GIPDT
Quick Start Guide
installation and wiring
suggested settings CORRIDOR
This product should be installed
in accordance with the current
IEE wiring regulations.
If in doubt consult a qualified
electrician.
•
Auto on—turns on when someone enters the corridor
•
Auto off—turns off when nobody in the room for 20 minutes
•
Lux—only turns on when there is little or no natural light
suggested settings BEDROOM AREA operation
Shallow back box?
Different wiring colours?
2 way wiring?
Refer to main datasheet.
www.cpelectronics.co.uk
%WD267 Issue 1
Remove top
and bottom
lugs if fitted
Do not
overtighten
Live
supply
Lamps
May have
red or
brown
sleeve
•
Manual on—turns on when top button pressed
•
Auto off—turns off when nobody in the room for 10 minutes
2
Com L1
Short press—lights on
Short press—lights off
The lights will turn off whilst the area is occupied.
The unit will reset to automatic operation after a
period of time.
•
Before using, the unit needs to be activated.
•
Press and hold the top button for more than 5 seconds.
The red LED will flash to indicate that has activated and
the unit will now operate.
activate
Corridor
The above settings turn light/s on when
someone enters the corridor, turn light/s
off when no movement is sensed for 20
minutes. Only turn light/s on if there is
little or no daylight.
Bedroom
The above settings turn light/s on when
the top button is pressed and turn light/s
off when no movement is sensed for 10
minutes.
Time setting 1min – 30min
The lights will turn off after the set time
period. When movement is detected, the
time period automatically restarts.
Clockwise = longer time period.
Daylight setting
Use this setting to adjust the point at
which daylight brightness automatically
turns lights on. Clockwise = turn on with
brighter daylight.
Auto on mode – in this mode lights
remain off if there is enough natural
daylight.
Toggle switch settings

6
activate
• Before using, the unit needs to be activated
• Press and hold the top button for more than 5 seconds. The red LED will flash to indicate
that it has activated and the unit will now operate
• If the unit is going to be out of use for prolonged periods (more than 6 months) it should
be deactivated by repeating the procedure above with the bottom button. This will help to
prolong battery life.
security mode
• Security mode can be turned on and off using the switches as shown in the ‘setup’ section
• When activated, security mode is used to switch on lighting when it gets dark, giving the
impression a house is occupied
• When the unit senses that it is dark outside, the lights will automatically switch on for a
period of 2 hours then switch off.
batteries
• The internal battery should last in excess of 3 years, dependent on usage
• When it needs replacing, a red LED will flash on the front of the unit
• Follow the steps opposite to replace the battery
• Use only good quality, 9V alkaline batteries type PP3
• Once the battery has been changed activate the unit as described in the ‘activate’ section.

7
battery replacement
1. Remove front
cover
2. Remove switch
cover
3. Lever out battery
4. Replace battery 5. Push into holder 6. Replace switch cover
7. Replace front cover
8. Activate

Lights turn off even though room is occupied
• Check location of sensor – see detection diagram
• Increase timing, typically 15 minutes for a living area.
Lights never turn off
• The lights will only turn off after no movement is detected for the time period. Is the
time period set too long?
Voltage 230VAC +/- 10%
Frequency 50Hz
Temperature 0ºC to 35ºC
Power 10A
Compliance BS EN60669-2-1 &
BS EN55015
EU registered design no. 000638069-0003,
000638069-0004