manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. RUD
  6. •
  7. Tools
  8. •
  9. RUD B-ABA Firmware update

RUD B-ABA Firmware update

1
B-ABA
RUD Ketten
Rieger & Dietz GmbH u. Co. KG
73428 Aalen
Tel. +49 7361 504-1370
Fax +49 7361 504-1171
[email protected]
www.rud.com
RUD-Art.-Nr.: 7906416-EN / 07.019
Lifting Point
loadable from any side
> B-ABA <
Safety instructions
This safety instruction/declaration has to be kept on le
for the whole lifetime of the product.
Translation of the original safety instruction
EN
B-ABA
EG-Konformitätserklärung
entsprechend der EG-Maschinenrichtlinie 2006/42/EG, Anhang II A und ihren Änderungen
Hersteller:
RUD Ketten
Rieger & Dietz GmbH u. Co. KG
Friedensinsel
73432 Aalen
Hiermit erklären wir, dass die nachfolgend bezeichnete Maschine aufgrund ihrer Konzipie-
rung und Bauart, sowie in der von uns in Verkehr gebrachten Ausführung, den grundle-
genden Sicherheits- und Gesundheitsanforderungen der EG-Maschinenrichtlinie
2006/42/EG sowie den unten aufgeführten harmonisierten und nationalen Normen sowie
technischen Spezifikationen entspricht.
Bei einer nicht mit uns abgestimmten Änderung der Maschine verliert diese Erklärung ihre
Gültigkeit.
Produktbezeichnung: Anschraubpunkt starr
_____________________________________________
B-ABA
_____________________________________________
Folgende harmonisierten Normen wurden angewandt:
DIN EN 1677-1 : 2009-03 DIN EN ISO 12100 : 2011-03
_________________ _________________
_________________ _________________
_________________ _________________
_________________ _________________
_________________ _________________
Folgende nationalen Normen und technische Spezifikationen wurden außerdem angewandt:
BGR 500, KAP2.8 : 2008-04
_________________ _________________
_________________ _________________
_________________ _________________
_________________ _________________
_________________ _________________
Für die Zusammenstellung der Konformitätsdokumentation bevollmächtigte Person:
Michael Betzler, RUD Ketten, 73432 Aalen
Aalen, den 22.09.2016
Dr.-Ing. Arne Kriegsmann,(Prokurist/QMB)
_____________________________________________
Name, Funktion und Unterschrift Verantwortlicher
EC-Declaration of conformity
According to the EC-Machinery Directive 2006/42/EC, annex II A and amendments
Manufacturer:
RUD Ketten
Rieger & Dietz GmbH u. Co. KG
Friedensinsel
73432 Aalen
We hereby declare that the equipment sold by us because of its design and construction,
as mentioned below, corresponds to the appropriate, basic requirements of safety and
health of the corresponding EC-Machinery Directive 2006/42/EC as well as to the below
mentioned harmonized and national norms as well as technical specifications.
In case of any modification of the equipment, not being agreed upon with us, this declara-
tion becomes invalid.
Product name:
Lifting point rigid
_____________________________________________
B-ABA
_____________________________________________
The following harmonized norms were applied:
DIN EN 1677-1 : 2009-03 DIN EN ISO 12100 : 2011-03
_________________ _________________
_________________ _________________
_________________ _________________
_________________ _________________
_________________ _________________
The following national norms and technical specifications were applied:
BGR 500, KAP2.8 : 2008-04
_________________ _________________
_________________ _________________
_________________ _________________
_________________ _________________
_________________ _________________
Authorized person for the configuration of the declaration documents:
Michael Betzler, RUD Ketten, 73432 Aalen
Aalen, den 22.09.2016 Dr.-Ing. Arne Kriegsmann,(Prokurist/QMB)
_____________________________________________
Name, function and signature of the responsible person
2B-ABA
Before initial usage of the RUD lifting point
B-ABA, please read carefully the safety
instructions. Make sure that you have un-
derstood all subjected matters.
Non-observance can lead to serious per-
sonal injuries and material damage and
eliminates warranty.
1 Safety instructions
ATTENTION
Wrong assembled or damaged lifting
points B-ABA as well as improper use
can lead to injuries of persons and
damage of objects when load drops.
Please inspect all lifting points before each
use.
• RUD lifting points B-ABA must only be used by in-
structed and competent persons considering BGR
500 (DGUV-rules 100-500) and outside Germany
noticing the country specic statutory regulations.
2 Intended use of the B-ABA
RUD lifting points B-ABA must only be used for the
assembly at the load or at lifting means.
They are intended to be hinged into lifting means.
RUD lifting points B-ABA can also be used as lashing
points to attach lashing means.
Loading from any side is permitted.
RUD lifting points B-ABA must only be used in the
hereby described operation purpose.
3 Assembly- and instruction manual
3.1 General information
• Capability of temperature usage:
When used at higher temperatures the working
load limit (WLL) of the lifting point must be redu-
ced as follows:
- -40°C up to 200°C no reduction
- 200°C up to 300°C minus 10 %
- 300°C up to 400°C minus 25 %
Temperatures exceeding 400°C are prohibited!
• RUD lifting points B-ABA must not be used with
aggressive chemicals such as acids, alkaline so-
lutions and their vapours.
• Please mark mounting position of lifting point with
a coloured contrast paint for better visibility.
3.2 Hints for the assembly
Basically essential:
• The material construction to which the lifting point
will be attached should be of adequate strength to
withstand forces during lifting without deformation.
The German testing authority BG/DGUV, recom-
mends the following minimum for bolt lengths:
1x M in steel (minimum quality S235JR[1.0037])
1.25x M in cast iron (however when castings of
lower strength [<200 MPa] are used the
thread engagement has to be at least 1,5xd)
2x M in aluminum alloys
2.5x M in light metals of low strength
(M = thread size, e.g. M20)
• The position of the lifting points must be carried
out in such a way that unintended movement like
turning or ipping will be avoided:
• For single leg lifts: the lifting point should be
vertically above the centre of gravity of the load.
• For two leg lifts: the lifting points must be
equidistant to/or above the centre of gravity
of the load.
• For three and four leg lifts. the lifting points
should be arranged symmetrical around the
centre of gravity, in the same plane if possible.
• Symmetry of loading:
Determine the necessary WLL of each lifting point
for a symmetrical or an unsymmetrical load by
using the following physical calculation formula:
Number of load bearing strands:
Table 1: Load bearing strands (compare to table 3)
• RUD lifting points B-ABA must be installed
by using the supplied ICE-bolts.
If needed, Vario-ICE-bolts can be ordered on re-
quest (compare chart 5 / pic. 4).
• A plane bolt-on surface must be ensured resp.
provided. Blind holes must be drilled deep enough,
that the supporting area of the B-ABA ts properly.
Tighten bolts with required torque value (see table
2).
• For a single use hand tightening with a spanner is
su󰀩ciant. Bolt supporting area must sitproper on
bolt-on surface.
• Check nally the correct assembly (see chapter 4,
Inspection criteria).
symmetric unsymmetric
two leg 2 1
three / four leg 3 1
WLL = necessary WLL (kg) of lifting point /
single strand (kg)
G = weight of load (kg)
n = number of load bearing strands
ß = Inclination angle of single strand
WLL=G
n x cos ß
3
B-ABA
3.3 User instructions
• Check frequently and before each initial operation
the whole lifting point B-ABA in regard of linger
ability as a lifting mean, regarding corrosion, wear,
deformation etc. (see chapter 4, Inspection crite-
ria).
ATTENTION
Wrong positioned or damaged lifting
points as well as improper use can
lead to injuries of persons and dama-
ge at property, when load falls down.
Please check all lifting points carefully
before every usage.
• Please check carefully the wear indicator markings
of the weld-on lifting point (see picture 4):
Pic. 1: Wear indicators
• To prevent unintended dismounting through shock
loading, rotation or vibration, thread locking uid
such as Loctite (depending on the application,
please pay attention to the manufacturer‘s in-
struction) could be used to secure the bolt, or use
form-closed devices.
• Please note that the lifting mean must be free mo-
veable within the lifting point B-ABA. When lifting
means (sling chains) are hinged or unhinged, no
pinching, shearing or joint spots must occure du-
ring the handling.
• Avoid damage of lifting means resulting from sharp
edges.
• If the lifting point B-ABA is used solely for lashing,
the value of the working load limit can be doubled:
LC = 2 x WLL
3.5 Hints for regular inspection
In time periods complying to the need or usage, a
technical expert must control at least once per year
the appropriateness of the lifting point. This inspec-
tion must also be done after each event of damage
or special incident.
4 Inspection criteria
Observe and control the following points before each
initial operation, in regular time intervals, after the as-
sembly and after special incidents:
• Completeness of the lifting point
• Complete, readable WLL statements as well as
manufacturer sign
• Deformation at load bearing components like base
body and bolts
• Mechanical damage, like strong notches, especial-
ly in areas where tensile stress occurs
• Reduction of cross-section due to wear >10 % (see
picture 1, wear indicators)
• Evidence of corrosion (Pitting)
• Cracks at the weld seam
• Ensure correct bolt and nut size, quality and length.
• Ensure compatibility of bolt thread and tapped hole
• Function and damage at the bolt, nut and/or thread.
Type torque
[Nm]
thread
d
wrench
size
SW
B-ABA 1.6 t 55 M10 16
B-ABA 3.2 t 100 M12 18
B-ABA 5 t 240 M16 24
B-ABA 10 t 450 M20 30
B-ABA 20 t 800 M24 36
B-ABA 31.5 t 950 M30 46
Table 2
Usage permitted:
no wear marks visible
Use prohibited:
Replacement criteria
reached. Material all the
way down to the wear
lenses has gone
4B-ABA
Method of lift
G
G
G
G
G
G
G
G
number of
legs 1 1 2 2 2 2 2 3/4 3/4 3/4
Angle of
inclination 0°-7° 90° 0°-7° 90° 0-45° 45°-60° Unsymm. 0-45° 45°-60° Unsymm.
Factor 1 1 2 2 1.4 1 1 2.1 1.5 1
Type For the max. total load weight >G< in metric tons [t]
B-ABA 1.6 t 1.6 1.6 3.2 3.2 2.2 1.6 1.6 3.4 2.4 1.6
B-ABA 3.2 t 3.2 3.2 6.4 6.4 4.5 3.2 3.2 6.8 4.8 3.2
B-ABA 5 t 5,0 5.0 10 10 7.1 5 5 10.6 7.5 5
B-ABA 10 t 10.0 10.0 20 20 14.1 10 10 21.2 15 10
B-ABA 20 t 20.0 20.0 40 40 28 20 20 42 30 20
B-ABA 31.5 t 31.5 31.5 63 63 45 31.5 31.5 67 47.5 31.5
At a lift with one strand and two parallel strands
where the inclination angles are at the max. ± 7°,
the lifting methode can be assumed as a vertical lift.
When lifting with two, three or four leg lifting means, inclination angles of
less than 15° shall be avoided, if possible (Risk of instability).
Table 3: WLL in [t]
Table 4: Dimensioning Subject to technical alterations
Pic. 2: Dimensioning B-ABA 1.6 t - 10 t
Pic. 3: Dimensioning B-ABA 20 t - 31.5 t
Type WLL
Lifting
[t]
A
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
H
[mm]
T
[mm]
L
[mm]
M weight
[kg/pc.)
Ref.-No.
B-ABA 1.6 t 1.6 75 16 100 35 16 62.5 55 55 46.5 13 4 x M10 0.9 7906266
B-ABA 3.2 t 3.2 92 23 137 50 21 86 70 75 65 16 4 x M12 2.0 7906267
B-ABA 5 t 5.0 113 27 172 60 28 108 84 95 80 24 4 x M16 4.1 7906268
B-ABA 10 t 10.0 146 38 228 80 36 141 110 125 105 25 4 x M20 9.3 7906269
B-ABA 20 t 20.0 200 52 272 115 40 188 150 75 148 30 6x M24 18.8 7906270
B-ABA 31.5 t 31.5 230 64 320 130 50 215 175 87.5 165 40 6x M30 29.5 7906271
Type K
[mm]
Lmax
[mm]
M used bolt Ref.-No.
ICE-bolt
B-ABA 1.6 t 125 118 4 x M10 M10 x 125 7905920
B-ABA 3.2 t 145 136 4 x M12 M12 x 145 7905921
B-ABA 5 t 185 174 4 x M16 M16 x 185 7908216
B-ABA 10 t 230 215 4 x M20 M20 x 230 7908217
B-ABA 20 t 265 245 6 x M24 M24 x 265 7908218
B-ABA 31.5 t 340 320 6 x M30 M30 x 340 7908418
Tabel 5: Vario-ICE-bolts (thread all the way up to the head)
Pic. 4: B-ABA bolt length

Popular Tools manuals by other brands

Festool FSK 250 instruction manual

Festool

Festool FSK 250 instruction manual

Alemite 595-B Service guide

Alemite

Alemite 595-B Service guide

Black & Decker RT 650 Original instructions

Black & Decker

Black & Decker RT 650 Original instructions

Sealey TC904 instructions

Sealey

Sealey TC904 instructions

NEO TOOLS 08-823 user manual

NEO TOOLS

NEO TOOLS 08-823 user manual

Woodstock D3156 instruction sheet

Woodstock

Woodstock D3156 instruction sheet

CRRC MS-ZD20S Operation & maintenance manual

CRRC

CRRC MS-ZD20S Operation & maintenance manual

Ryobi RB61 Operator's manual

Ryobi

Ryobi RB61 Operator's manual

LEGRAND 332 60 manual

LEGRAND

LEGRAND 332 60 manual

MSW MSW-ETTBMW-06 user manual

MSW

MSW MSW-ETTBMW-06 user manual

Bostitch SB156SX-1-E Original instructions

Bostitch

Bostitch SB156SX-1-E Original instructions

CMi C-AMBS-7.2 Set Original instructions

CMi

CMi C-AMBS-7.2 Set Original instructions

BGS technic 3065 instruction manual

BGS technic

BGS technic 3065 instruction manual

Fixi AP4 Operation manual

Fixi

Fixi AP4 Operation manual

Makita EY403MP instruction manual

Makita

Makita EY403MP instruction manual

iKarus C42 owner's manual

iKarus

iKarus C42 owner's manual

Ryobi P29016 Operator's manual

Ryobi

Ryobi P29016 Operator's manual

Clas Ohlson RP8031K6 quick start guide

Clas Ohlson

Clas Ohlson RP8031K6 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.