RG-EasyGate Series Hardware Installation Guide V1.28
One USB port.
One reset button (RESET), which is on the right side of the serial port.
LED Indicators There are seven LED indicators: PWR, SYS, USB, GE1, GE2, SFP1
and SFP2.
Interface Standard Ethernet: 10Base-T/100Base-TX/1000Base-TX, 1000BASE-SX/LX/ZX
Configuration port (console port): RS-232
Dimension (W x H x D) 440 x 43.6 x 200 mm (excluding the foot pad)
Voltage 100–240 V; 50–60 Hz
Power Consumption Less than 35 W
Temperature: 0°C to 50°C
Working Environment Humidity: 10% to 90% RH (non-condensing)
Since there are numerous types of U-disk, we cannot ensure that the system supports all of them. The
Kingston U-disk with FAT 32 are recommended to be used.
LED Indicators of Ruijie EG1000C Breakout Gateway
Table 1-2 LED Indicators of Ruijie EG1000L V1.0 Breakout Gateway
LED Indicators Working Status
PWR Solid green indicates the power supply is working properly.
SYS
Blinking green indicates the system is being initialized.
Solid green indicates system initialization has completed.
Solid red indicates system warning.
USB Solid green indicates the USB disk is inserted.
Blinking green indicates data reading/writing.
0-23 Solid green indicates the link that the port connects to is up.
Blinking green indicates data is being transceived at the port.
GE0/1, GE0/2
Solid green indicates the 1000 M link that the port connects to is up.
Blinking green indicates data at a rate of 1000 M is being transceived at
the port.
Solid orange indicates the 10 M/100 M link that the port connects to is
up.
Blinking orange indicates data at a rate of 10 M/100 M is being
transceived at the port.
SFP1, SFP2 Solid green indicates the link that the port connects to is up.
Blinking green indicates data is being transceived at the port.
Reset Button
To reset the breakout gateway system, press this button for less than
three seconds.
To restore the breakout gateway to default settings and reset the
system, press this button for more than three seconds.