manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Russound
  6. •
  7. Receiver
  8. •
  9. Russound SaphIR 862P Plasma Eye User manual

Russound SaphIR 862P Plasma Eye User manual

PRODUCT OVERVIEW
The SaphIR 862P Plasma Eye receives IR signals from a handheld IR remote
control and relays these signals to the audio/video equipment for operation
from another room. Mounts through a circular hole with a diameter of 0.5”,
requires a minimum clearance of 2.0” behind the face of the mounting sur-
face, and will mount in a panel with a maximum thickness of 1.75”.
FEATURES
• Plasma-friendly - can be placed near plasma TVs and displays.
• CFL-friendly - allows installations in areas with compact fluorescent
lighting. Works in most lighting environments.
• Comes with interchangeable white, black and brass bezels to easily
customize your installation.
• Blue IR confirmation LED.
• Can easily be mounted in many in-wall speakers (such as Russound
Advantage® and Atmosphere) and custom cabinets.
• Wide band IR. Receives IR from many types of remotes.
BEZEL EXCHANGE
The SaphIR 862P Plasma Eye comes with three bezels (white, black, brass) for
more installation color choices.
To remove the bezel, hold the barrel steady and upright and twist the bezel
until it clears the top of the barrel. Make sure the small tinted plasma filter
stays in place at the end of the barrel.
To replace the bezel, center the bezel over the filter and barrel, thread onto
the barrel end and twist until snug.
Plasma Filter
Bezel
Nut
Barrel
Mounting
Surface
Front
Mounting
Surface
Rear
Washer
Max thickness
1.75”
Min. clearance
2.0”
SaphIR
862P Plasma Eye
Mini Infrared Receiver
Plasma and CFL Friendly
Instruction Manual
Panel
Face
INSTALLATION
The SaphIR 862P Plasma Eye is installed into a circular hole 0.5” in diameter.
Remove the nut from the receiver’s barrel. Insert the Eye (wire end first)
until the bezel is flush with the surface. Rethread the nut onto the barrel
until it is snug against the rear of the mounting surface. If necessary, use
one or both of the included washers for a more secure installation into soft
or thin materials.
CONNECT TO
846C OR 1201A
POWER
SUPPLY
EMITTER PORTS
857
CONNECTING
BLOCK
123456
IR R
ECEIVER
I
N
IR C
OMMON
I
N
IR C
ONFIRM
+
12VDC
GND
STATUS
SIGNAL
EMITTERS
STATUS
+12VDC
POWER
+12VDC
DESIGNED IN USA MADE IN CHINA
857 I
NFRARED
C
ONNECTING
B
LOCK
12 VDC
SIGNAL (White)
+12VDC (Black)
GND (Black)
WIRE CONNECTIONS
Direct Connection from 862P Plasma Eye to Connecting Block
Connect the SaphIR 862P Plasma Eye to the 857 or equivalent connecting
block. Connect GND (GROUND), IR (SIGNAL) and Voltage (+12VDC ) to con-
nector on the 857.
PACKAGE INCLUDES:
SaphIR 862P Plasma Eye IR Receiver (1)
Colored Bezel (3: white, black, brass)
Terminal Strip (1)
Screws (2)
Two-way Mounting Tape (1)
Washers (2)
SPECIFICATIONS
Receive Frequency: 36kHz to 58kHz
Transmit Frequency: 40kHz and 56kHz
Range: On Axis – 55ft to 80ft
30º Off Axis – 30ft to 55ft
Power: 12VDC 31mA max.
Dimensions: 0.46” Diameter x 2.03”D
Mounting Cord Length: 6.5 ft.
WIRE CONNECTIONS
Extended Leads from 862P Plasma Eye to Terminal Strip to Connecting Block
The extended connection between the IR receiver and the connecting block
should be made with twisted-pair wiring (i.e., CAT-5e cable). It may be nec-
essary to use shielded twisted-pair wiring if the wiring is exposed to inter-
ference from power wiring centers or from broadcast signals (FM, TV, etc.)
located nearby. The installer should determine the cable type needed to suit
the local conditions of the installation. A terminal strip is included for
extending the leads.
Russound offers both CAT-5e cable (AWCAT5) and shielded twisted-pair
cable (AW2260AB) which are suitable for IR installations. Contact Russound
for ordering information.
857
CONNECTING
BLOCK
123456
IR R
ECEIVER
I
N
IR C
OMMON
I
N
IR C
ONFIRM
+
12VDC
GND
STATUS
SIGNAL
EMITTERS
S
TATUS
+12VDC
P
OWER
+12VDC
DESIGNED IN USA MADE IN CHINA
857 I
NFRARED
C
ONNECTING
B
LOCK
Terminal
Strip
862P
Plasma
Eye
CAT-5e cable
Orange Pair
Open
Orange
Orange/White
Brown
Brown/White
Brown
Brown/White
Green
Green/White
Green
Green/White
Blue
Blue/White
Blue
Blue/White
Open
Drain Orange Pair
and Blue/White to
GND on 857
+12VDC
(Black)
SIGNAL
(White)
GND
(Black)
862P Eye CAT-5e 857
SIGNAL BL SIGNAL
+12VDC GR/GRW +12VDC
GND BR/BRW GND
OR/ORW GND
BLW GND
5 Forbes Rd. Newmarket, NH 03857, USA
Tel 603.659.5170 • Fax 603.659.5388
e-mail: [email protected]
LIMITED WARRANTY
The Russound®SaphIR 862P Plasma Eye is fully guaranteed for Two (2) years from the date of purchase
against all defects in materials and workmanship. During this period Russound will replace any defec-
tive parts and correct any defect in workmanship without charge for either parts or labor. For this war-
ranty to apply, the unit must be installed and used according to its written instructions. If service is
necessary, it must be performed by Russound. The unit must be returned to Russound at the owner’s
expense and with prior written permission. Accidental damage and shipping damage are not consid-
ered defects under the terms of the warranty. Russound assumes no responsibility for defects resulting
from abuse or servicing performed by an agency or person not specifically authorized in writing by
Russound. Damage to or destruction of components due to improper use voids the warranty. In these
cases the repair will be made at the owner’s expense. To return for repairs, the unit must be shipped to
Russound at the owner’s expense, along with a note explaining the nature of the service required.
Be sure to pack in a corrugated container with at least 3 inches of resilient material to protect the unit
from damage in transit.
Before returning a unit for repair, call Russsound at (603) 659-5170 for a Return Authorization num-
ber. Write the RA number on the shipping label and ship to: Russound, ATTN: Service, 5 Forbes Road,
Newmarket, NH 03857.
Russound sells products only through authorized Dealers and Distributors to ensure that customers
obtain proper support and service. Any russound product purchased from an unauthorized dealer or
other source, including retailers, mail order sellers and online sellers will not be honored or serviced
under existing Russound warranty policy. Any sale of products by an unauthorized source or other
manner not authorized by Russound shall void the warranty on the applicable product.
Rev. 1 09/27/05

Other Russound Receiver manuals

Russound SaphIR 858P Plasma In-Wall User manual

Russound

Russound SaphIR 858P Plasma In-Wall User manual

Russound CAM6.6X User manual

Russound

Russound CAM6.6X User manual

Russound 854P User manual

Russound

Russound 854P User manual

Russound 860 PHANTOM User manual

Russound

Russound 860 PHANTOM User manual

Russound SaphIR 860P Phantom User manual

Russound

Russound SaphIR 860P Phantom User manual

Russound VBHD User manual

Russound

Russound VBHD User manual

Russound SaphIR 858 User manual

Russound

Russound SaphIR 858 User manual

Russound X1-TX8 User manual

Russound

Russound X1-TX8 User manual

Russound Decora 858 User manual

Russound

Russound Decora 858 User manual

Russound DMS-3.1 User manual

Russound

Russound DMS-3.1 User manual

Russound ALTX-WIRI 2D User manual

Russound

Russound ALTX-WIRI 2D User manual

Russound CAM6.6X-S1/S2 User manual

Russound

Russound CAM6.6X-S1/S2 User manual

Russound SaphIR 854 User manual

Russound

Russound SaphIR 854 User manual

Russound SAPHIR 854 User manual

Russound

Russound SAPHIR 854 User manual

Russound SaphIR 862 Eye User manual

Russound

Russound SaphIR 862 Eye User manual

Russound SAPHIR 860 User manual

Russound

Russound SAPHIR 860 User manual

Russound VMR1 User manual

Russound

Russound VMR1 User manual

Russound SaphIR 862 Eye User manual

Russound

Russound SaphIR 862 Eye User manual

Russound CAM66T 1 User manual

Russound

Russound CAM66T 1 User manual

Popular Receiver manuals by other brands

RF Elements TwistPort Shielded Adaptor V2 installation guide

RF Elements

RF Elements TwistPort Shielded Adaptor V2 installation guide

Shure U4S Programming guide

Shure

Shure U4S Programming guide

TV Star T1030 HD USb PVR user manual

TV Star

TV Star T1030 HD USb PVR user manual

Yamaha HTR-6140 owner's manual

Yamaha

Yamaha HTR-6140 owner's manual

Aiwa NSX-DS15 Service manual

Aiwa

Aiwa NSX-DS15 Service manual

ANTIFERENCE DVB-T2 DIGIBOX user manual

ANTIFERENCE

ANTIFERENCE DVB-T2 DIGIBOX user manual

Denson DS-500 Operation manual

Denson

Denson DS-500 Operation manual

Yamaha RX-V583 Firmware update procedure

Yamaha

Yamaha RX-V583 Firmware update procedure

Kathrein UFS 946/CI+ operating instructions

Kathrein

Kathrein UFS 946/CI+ operating instructions

Topcon BR-1 Operator's manual

Topcon

Topcon BR-1 Operator's manual

Sirius Satellite Radio SportsterIR SP-R2 user guide

Sirius Satellite Radio

Sirius Satellite Radio SportsterIR SP-R2 user guide

LG SH92TB-S owner's manual

LG

LG SH92TB-S owner's manual

Pioneer Elite VSX-33 Specifications

Pioneer

Pioneer Elite VSX-33 Specifications

Spektrum SR201 instruction manual

Spektrum

Spektrum SR201 instruction manual

Safran RX-1 user manual

Safran

Safran RX-1 user manual

CYP CRS-232 Operation manual

CYP

CYP CRS-232 Operation manual

Denon AV SURROUND RECEIVER AVR-891 owner's manual

Denon

Denon AV SURROUND RECEIVER AVR-891 owner's manual

Pioneer VSX-1121-K Specifications

Pioneer

Pioneer VSX-1121-K Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.