4
BEFORE USE - IMPORTANT!
This SA CYCLONE Filtration Unit must not be taken into a Zone 0 area.
The ignition hazards have been assessed and mitigated through design and filter selection to
allow operation in zone 1 and 2, if used in zone 1 or 2 the G4 ATEX Panel Filter must be fitted.
Contact SA Equip if you need to purchase this filter.
When used in conjunction with the SA CYCLONE EX Air Mover it is recommended to operate it with the
Air Mover downstream of the Filtration Unit in the clean air.
When operating in zone 1 or 2 the unit must be suitably bonded to an external earth point using studs
provided on the unit end panels. Check integrity of internal earth connections prior to use including EX
panel filter earth connection.
DURING USE
SETTING UP AND OPERATING
THE SA CYCLONE AIR MOVER
Check that the Filtration Unit is safe for use and has no
defects, paying attention to the air passage, filters, lid &
duct adaptors.
Position and set up the Filtration Unit according to the
previous instructions and ensure it is on an even and flat
surface.
If ducting is required, it should be fitted to the appropriate
size duct adaptor which is normally pre-fitted to the
Filtration Unit, but otherwise should be secured at all
5 fixings points using the fasteners provided (torque
setting 3.2Nm).
Ducting used should be SA CYCLONE Anti-static Ducting following the separate instructions provided.
It should be connected securely to the duct adaptor with the fixing strap installed on the ducting.
The equipotential bonding lead from the ducting should be connected to one of the 2 earth bolts installed
on the filtration unit.
If the Filtration Unit gets damaged during use it must be immediately disconnected and removed to
a safe area for inspection and test. Correct use of the equipment should help to ensure that it is not
damaged. If you would like more information on ancillary products, please contact the Sales Team on