SALCOR INC
Page 3 of 14
I.INSTALLATION INSTRUCTIONS
WARNING! Improper Connection of the APPLIANCE GROUNDING
CONDUCTOR Can Result in the Risk of an Electric Shock.
Check with a qualified electrician or service representative if you are in doubt about
whether the appliance is properly grounded.
Open and carefully unpack the shipping carton. Check for any damage that may have
occurred in shipping. If there are any problems,call SALCOR INC. at 760-731-0745 or
Fax to SALCOR INC. at 760-731-2405 and explain the problem(s).
The following list describes the components that are contained in the shipping carton.
1. Disinfection chamber: 3-inch diameter ABS pipe with 4-inch inlet and outlet hubs.
2. Disinfection sub-assembly consisting of an anodized aluminum frame supporting a
Teflon®sheath containing a pure fused quartz tube.This complete item is packed
inside of the above listed 3-inch disinfection chamber.
3. Riser pipe: 4-inch diameter ABS pipe.
4. 1-inch white PVC handle which is used for inserting and removing the disinfection
sub-assembly. It is bubble-wrapped inside of the above listed 4-inch riser pipe.
5. The Long Life UV lamp is bubble-wrapped and packed inside of the 1-inch white
PVC handle.
6. Electrical sub-assembly junction box (rated NEMA 6P) with pre-wired alarm board,
electronic ballast, and the lamp cable supplying power to the UV lamp.
7. Two 4-inch Schedule 40 ABS pipe couplings.
8. Watertight connection for bringing the power and alarm wires into the junction box.
Flexible Watertight conduit should be used to connect to this fitting.
9. Dielectric Grease, to be used on the inside of the boot on the UV lamp socket.
There will be some additional items to be supplied by the installer
1. Teflon®tape for sealing PVC and Watertight connectors
2. ABS cement (also multipurpose cement if bonding to PVC pipe)
3. Isopropyl (rubbing) alcohol for cleaning the subassembly unit before installing
4. Glycerin (available from drug stores) for lubricating the gaskets of the subassembly
5. Power and Alarm Wires. Wire all circuits with insulation rated 600 VAC min.
6. Power and Alarm Wire Watertight Flexible Conduit for connecting to the Junction
Box watertight connector
7. Irrigation Valve Box if the 3G Unit is to be installed at or above ground
8. Silicon Adhesive Sealant, also called RTV
WARNING! This Device Produces Potentially Harmful UV Light.
Always Protect Your Eyes and Skin From Exposure to UV Light.
Disconnect Power Before Replacing or Servicing the 3G Unit/Lamp.