Salsbury Industries 3700 Series User manual

SALSBURY INDUSTRIES
1010 East 62nd Street, Los Angeles, CA 90001-1598
Ph: 1-800-624-5269 Int’l Ph: 323-846-6700
Fx: 1-800-624-5299 Int’l Fx: 323-846-6800
www.mailboxes.com engineering@mailboxes.com
Installation instructions are provided as general guidelines. It is advised that a professional installer be consulted. Salsbury Industries assumes no product assembly or installation liability.
Copyright © 2014 Salsbury Industries. All rights reserved. (P/N 370137, Rev. 18, 2/27/14) Page 1 of 4
U.S.P.S. APPROVED
U.S.P.S. APPROVED
With its high-security design and quality construction, Salsbury’s 3700 series USPS approved 4C horizontal mailboxes will provide years of
maintenance free service. These units meet all the requirements of USPS-STD-4C, the new high-security standard developed by the United
States Postal Service.
Typical Installation
Preparatory Steps
1. Have mailboxes and instructions on hand before starting wall
construction.
2. Unpack and review contents of shipping cartons.
3. Gather tenant and parcel locker keys and store in a secure place.
4. Read installation instructions document thoroughly.
5. Determine rough opening size(s).
6. Determine rough opening location above finished floor.
7. Determine framing configuration and location.
8. Procure materials for wall construction.
Rough Opening Dimensions
Each unit requires a separate opening in the drywall. Each pair of
units will have a 2x4 stud separating them. The trim frames cannot
be butted together. There will be a space between edges of trim
frames of approximately 3/4” when 2x4 studs with drywall separate
the mailboxes.
Calculation Of Space Required for Multiple Units
For overall width of mailbox installation, add all of the stud spacing
and subtract ¾”. For overall height of units, see the dimension chart
below.
Dimensions –FRONT LOADING
WIDTHS
1 COLUMN
2 COLUMN
Overall
16-3/8”
31-1/8”
Rough Opening
15-5/8”
30-3/8”
Stud Spacing
17-1/8”
31-7/8”
HEIGHTS
OVERALL
ROUGH OPENING
Maximum Height
56-3/4”
56”
15 Doors High
55”
54-1/4”
14 Doors High
51-1/2”
50-3/4”
13 Doors High
48”
47-1/4”
12 Doors High
44-1/2”
43-3/4”
11 Doors High
41”
40-1/4”
10 Doors High
37-1/2”
36-3/4”
9 Doors High
34”
33-1/4”
8 Doors High
30-1/2”
29-3/4”
7 Doors High
27”
26-1/4”
6 Doors High
23-1/2”
22-3/4”
5 Doors High
20”
19-1/4”
4 Doors High
16-1/2”
15-3/4”
3 Doors High
13”
12-1/4”
4C Horizontal Mailboxes –3700 Series
FRONT LOADING Installation Instructions
IMPORTANT !
After installing the unit, contact your local postmaster –the USPS will
provide and install its own master lock on your mailbox unit. Hardware
and instructions for installing the master lock is included inside the unit.
Please provide the hardware and instructions to the USPS
representative when they arrive to install the lock.

SALSBURY INDUSTRIES
1010 East 62nd Street, Los Angeles, CA 90001-1598
Ph: 1-800-624-5269 Int’l Ph: 323-846-6700
Fx: 1-800-624-5299 Int’l Fx: 323-846-6800
www.mailboxes.com engineering@mailboxes.com
Installation instructions are provided as general guidelines. It is advised that a professional installer be consulted. Salsbury Industries assumes no product assembly or installation liability.
Copyright © 2014 Salsbury Industries. All rights reserved. (P/N 370137, Rev. 18, 2/27/14) Page 2 of 4
Wall Construction
Particular attention must be paid to wall framing to provide a strong
and secure attachment of the mailbox units. Stud spacing must be
accurate to ensure that there is minimum space between the studs
and the mailbox frame and minimum mailbox frame distortion when
the fasteners are tightened between the frame and the studs. Studs
must be installed plumb and square to further ensure proper fit of the
mailboxes.
Notes
1. Although these mailboxes have been tested and approved for
both outdoor and indoor use, some shelter from direct weather
conditions should be provided, especially in areas with heavy rainfall.
This provides protection for the mail, the delivery personnel, and the
mail patrons.
2. The mailboxes are shipped fully assembled.
3. Hardware is included to fasten each unit into a wood framed wall.
4. Trim is an integral part of the mailbox assembly. There is no other
snap-on trim to install.
USPS Regulations
The mailboxes must be installed according to Postal Regulations.
1. The floor of the lowest patron mailbox shall be no less than 28”
above the finished floor.
2. The patron lock in the highest mailbox shall be no more than 67”
above the finished floor.
3. The USPS Arrow lock (master door lock) opening must be a
minimum of 36” and a maximum of 48” above the finished floor.
4. The floor of the lowest parcel locker shall be no less than 15”
above the finished floor.
5. The master access door(s) must be allowed to open a minimum of
90 degrees with no obstruction.
6. There must be at least one parcel locker for every ten patron
mailboxes in installations of 10 or more patron mailboxes. There is
no requirement for parcel lockers in installations of less than 10
patron mailboxes, but one or more parcel lockers are recommended.
Installation Instructions
1. Construct wall and mailbox support structure with drywall, 2x4
lumber, and 3/8” plywood. 2x6 lumber may be used for a stronger
wall.
2. Cut a hole(s) in the wall according to the rough opening
dimensions. Each mailbox unit assembly should have its own
opening in the drywall.
3. Place unit(s) into rough opening(s). Open the carrier access door
and open the front doors by lifting the latch handle on the left behind
the carrier access door. See illustration on page 3 for location of
carrier access door. Note the mounting hole locations and drill pilot
holes into the studs. Securely fasten to the support framing with the
screws provided. See illustration below. Install screws into all holes
provided in both right and left side vertical trim frame members.
Caution: Do not deform, force, or twist the frame to fit an incorrect
rough opening or against an irregular surface. Do not over-tighten
the installation screws. If necessary, shim the small space between
the stud and the vertical, extruded-aluminum trim frame.
4. Test all master doors, patron doors, and parcel locker doors to
ensure that they open and swing freely without binding or sticking.
Fastening Mailbox Unit to Framing

SALSBURY INDUSTRIES
1010 East 62nd Street, Los Angeles, CA 90001-1598
Ph: 1-800-624-5269 Int’l Ph: 323-846-6700
Fx: 1-800-624-5299 Int’l Fx: 323-846-6800
www.mailboxes.com engineering@mailboxes.com
Installation instructions are provided as general guidelines. It is advised that a professional installer be consulted. Salsbury Industries assumes no product assembly or installation liability.
Copyright © 2014 Salsbury Industries. All rights reserved. (P/N 370137, Rev. 18, 2/27/14) Page 3 of 4
USPS Height regulations

SALSBURY INDUSTRIES
1010 East 62nd Street, Los Angeles, CA 90001-1598
Ph: 1-800-624-5269 Int’l Ph: 323-846-6700
Fx: 1-800-624-5299 Int’l Fx: 323-846-6800
www.mailboxes.com engineering@mailboxes.com
Installation instructions are provided as general guidelines. It is advised that a professional installer be consulted. Salsbury Industries assumes no product assembly or installation liability.
Copyright © 2014 Salsbury Industries. All rights reserved. (P/N 370137, Rev. 18, 2/27/14) Page 4 of 4
Wall Framing Recommendation
Table of contents
Other Salsbury Industries Indoor Furnishing manuals
Popular Indoor Furnishing manuals by other brands

Vivo
Vivo Blue Kids DESK-V303B instruction manual

MARSRHINO
MARSRHINO SPYDER S Series manual

nest
nest Dakota High Sleeper MG 7507 Assembly instructions

Trinity
Trinity TLS-0209 owner's manual

Finori
Finori PRO5/137 Assembly instructions

MARCKERIC
MARCKERIC SIDEBOARD 3D3DR1H CUTWOOD 14180 Assembly instructions