2. Installation of the boiler module RXWBC605
iT500BM Installer Manual 07
RF Transmission
The receiving range between your thermostat and the RF Boiler Control is around
100 metres in open air, however many factors can aect the RF transmission
and shorten the operating distance, e.g. shielding by thick walls, foil back
plasterboard, metal objects such as ling cabinets, general RF interference, and
so on.The operating range is generally around 30 metres, which is large enough
for most household applications.
RXWBC605 RECEIVER
C
First plug in the connector block C ensuring
correct orientation. Remember to ensure
the block is fully connected.
B
A
1. Switch o the boiler at its main supply.
Remove the outer casing and front fascia to
allow access to the main control panel.
2. Remove cover panel A upwards to remove.
3. Pull top tab B upwards, then outwards to
remove blanking plate or existing control.