Samsung Healthy Living TSR-301S User manual

97.9°F
36.6°C
98.4°F
36.9°C
97.9°F
36.6°C
98.4°F
36.9°C
HEAT
POCKET
HEAT
POCKET
98.8°F
37.1°C
98.8°F
37.1°C
97.7°F
36.4°C
98.1°F
36.7°C
BATTERY COVER
ON/OFF BUTTON
DIGITAL DISPLAY WINDOW
PROBE TIP
Th an k yo u fo r pu rc ha si ng S am su ng H ea lt hy
Li vi ng ®30 Seco nd D ig it al Th er mo me ter w it h
beeper, me mory and high tempe rature alarm.
Before usin g your new thermo meter p lease read
and foll ow in stru cti ons to i nsu re mos t acc urat e
body tem peratur e reading s. Inform ation her ein
and p roduct are no t meant to be a sub stitute for
the advice p rovided by a medica l professional.
Nor mal Bo dy Tem pera ture f luctuates durin g the
cou rs e of a d a y an d de pe n ds o n lo c at io n of
te mp era tu re re ad ing . Th e ge ner al ly ac ce pte d
"no rmal" b ody tem perat ure is 98 .6°F( 37.0° C) for
oral . An axill ary or underarm rea ding is us ually is
1.0 °F (0.5 °C) low er 97.6 °F (36. 4°C) and a rect al
temperature is usually 1.0°F higher (0.5°C) 99.6°F
(37 .5°C ). Bod y temperature rea ding s tend t o be
lowe st in the mor ning hours from 2 a.m . to 4 a.m.
while yo ur bod y is re stin g and i s high est durin g
la te af ter noo n hou rs from 4 p.m. becaus e you r
body has bee n active througho ut the day.
Prior to e ach u se clean th e the rmom ete r with a
so ft clo th mo istened w ith r ubbing al coh ol (70%
is opro pyl a lco hol ) dil ute d wit h warm water, OR
wash wit h cold, soapy wa ter. An intact unit can be
s u b m e r s e d i n 5 0 % w a t e r a n d 5 0 % a l c o h o l ;
ho wev er do not soa k for a n ext end ed pe rio d of
time. Be sure to dry thermometer thoroughly using
soft clot h.
To make te mperature t aking more hy gienic and to
h e l p p r e v e n t c r o s s - c o n t a m i n a t i o n i t i s
recommended to use S amsung Dis posable Probe
Covers (model # TSP-001 ) each time te mperature
is taken.
When the " 188.8" symbol is continuo usly flashin g,
the batter y needs to be replaced with
an SG3 silve r oxide type.
1.Slide ba ttery cap away from u nit.
2. Rem ov e the b atter y usi ng a s mal l Phill ips -
hea d or jeweler' s screwdriv er and insert n ew
battery wi th the positive (+) s ide facing up.
3. Car efully s lide bat tery cap b ack into i ts place ,
mak ing su re the c ap is se cure ly fit t o protect
battery fr om moisture.
1.C lean a nd prop erly d isin fect th e ther mometer
accordin g to the instructio ns provided.
2. P lac e a new or clea n and u nda mag ed pr obe
cover care fully over the ther mometer tip.
3 . S e l e c t o r a l , a x i l l a r y o r r e c t a l a s y o u r
measurem ent site.
4. Pr ess On /Off b utto n to activate therm omet er.
The d igita l display wil l show th e follo wing a nd
the therm ometer will bee p.
NOTE : Rel ax and wait appr oximately 5 mi nutes with you r
mo ut h cl os ed be fo re t ak in g a rea di ng i f yo u'v e ju st
co ns um ed a ny ho t or c ol d be ve rag es , ex er ci sed o r
smok ed. This wi ll reduce c hances of p ossible h igh or low
temperatu re readings.
1. P lac e a new o r cle an an d un dam age d pro be co ver
carefully o ver the thermometer ti p.
2. P la ce t he p ro be t ip u nd er t he t ong ue a s ne ar a s
pos sible t o the hea t pock et. The di agram b elow a lso
show s the tempe rature va riables b y not plac ing the tip
in the h eat pock et areas . Hold the t hermom eter sti ll in
th e sam e spo t and m out h shou ld re mai n clo sed f or
most accura te reading.
3. Th e curren t tempe rature i s shown a nd the °F (° C) will
continue to f lash during the readin g.
4. Wh en pe ak tem pera ture i s reac hed , the °F ( °C) wi ll
stop a flashi ng and four quick beeps wi ll sound.
5. To tu rn the unit o ff, press t he On/Off b utton, ot herwise
the un it will a utomat ically s hut-o ff after a pproxi matel y
10 minutes to p reserve battery life .
This is the LCD d isplay test, w hich insures
al l p art s of th e dis pla y are f unc tio ni ng
pr op er ly . Con ti nu e to h ol d the b ut to n
swi tch d own over 2 s econd s, the dis play
will flas h alternatively ° C/°F icons. Rele ase
button on preferable m ode of read-out.
Thi s disp lay sh ows th e last t empe rat ure
reading aft er °C/°F select ion.
Af te r the d is pla y of t he la st m eas ur ed
re a d i n g , th e u n i t wi l l p e r f o r m a s e l f -
ca libr atio n ( stan dar d temp era ture ) and
display 97. 7°F for about one s econd.
The "Lo" wi th the flashing °C ( °F) indicates
t h e th e r m o m e t e r i s re a d y t o t a k e a
t e m p e r a t u r e r e a g i n g ( I f " E R R " i s
d i s p l a y e d , a ma l f u n c t i o n ha s b e e n
dete cted and th ermomet er will nee d to be
replaced. )
T h e b e s t w a y t o f i n d o u t y o u r n o r m a l b o d y
temp erature i s to measure yourse lf when you are
fe eli ng we ll. R eco rd yo ur re adi ngs twice a da y
(ea rly mor ning and late a ftern oon). The ave rage
o f t h e t w o r e a d i n g s i s y o u r n o r m a l b o d y
temperature. Any d eviation from this may in dicate
an i l ln es s an d yo u sh ou ld c o ns ul t a me di ca l
professi onal.
Th is th er mom eter ha s a bui lt -in a larm to w arn
user of hi gher than norm al temperatu re. If reading
excee ds 99.5°F ( 37.5°C) eight sets of t hree quick
beeps will s ound.
INSTRUCTIONS FOR USE
30 Second Digital Thermometer
with Accu-FastTM Technology
CLEANING INSTRUCTIONS &
USING DISPOSABLE PROBE COVERS
BATTERY
BODY TEMPERATURE
How to know your Normal Body
Temperature
HIGH TEMPERATURE ALARM
To replace battery,
Caution: Please properly dispose of the old battery away
from small children and heat.
TAKING AN ORAL TEMPERATURE
Approxim ate reading time: 3 0 seconds
NO TE : Re cta l te mpe rat ure s are th e mos t ac cur ate
met hod fo r inf ants a nd sma ll chi ldre n. Oth erwi se thi s
method sh ould only be used wh en it is difficult to t ake an
ora l or axill ary mea surem ent. Re ctal tem perat ures ar e
gen erall y 1.0° F (0.5 °C) hig her th an ora l read ings. F or
hygie nic reasons , once thermom eter is used re ctally, do
not use ora lly.
1. P lac e a new or c lea n and u nda mag ed pro be
cover care fully over the therm ometer tip.
2. Have your c hild lie stomach dow n on your lap.
3. App ly a water- solubl e lubrica nt to the tip o f the
thermome ter and around rectu m.
4. Hol d your chi ld still an d gently i nsert th e probe
a max imum of 1 i nch int o the re ctum. I f chil d
i s le s s t h a n 6 mo n t h s o l d , g e n t l y i n s e r t a
maximum of 1 /4 to 1/2 inch into the re ctum.
5. When p eak tempera ture is reach ed, the °F (°C )
wi ll s to p fla sh in g and f ou r qu ick b ee ps w ill
sound.
6. T o turn t he un it of f, pr ess th e On/ Off b utto n,
ot herw ise t he un it wi ll aut oma tic ally s hut -of f
ap pro xi mat ely a ft er 10 m inu te s to pr ese rv e
battery l ife.
TAKING A RECTAL TEMPERATURE
Approxim ate reading time: 3 0 seconds
NO TE : Ax ill ary t emp era tur es ar e gen era ll y 1.0 °F
(0.5°C) lo wer than oral readi ngs.
1. Wipe under arm area with a dry towel.
2. Pla ce a new or c lean and u ndamag ed probe c over
carefully o ver the thermometer ti p.
3. Pla ce the pr obe tip un der the a rm so that t he tip is
t o u c h i n g t h e s k i n w i t h t h e t h e r m o m e t e r
perpendic ular (vertical) to the body.
4. Po sit ion ar m acro ss th e ches t so the p rob e tip is
wel l cover ed by the ar m. This i nsure s the amb ient
temperatu re does not affect the pro be.
5. When p eak tempe rature is r eached, th e °F (°C) wil l
stop flash ing and four quick b eeps will sound.
6. T o tu r n th e un i t o f f, p r e s s th e On / O f f bu t t o n ,
ot he rw is e th e un it w il l au to ma ti ca ll y sh ut -o ff
appr oximat ely after 1 0 minute s to preser ve batte ry
life.
TAKING AN AXILLARY
TEMPERATURE (UNDERARM)
Approxim ate reading time: 5 0 seconds
SPECIFICATIONS
Model Number
Display
Display Resolution
Measurement Range
Measurement Location
Temperature Scales
Accuracy
High Temperature Alarm
Completed Measurement
Probe Covers
Battery Type
Battery Life
Automatic Shut-off
Memory
Waterproof
Ambient Range
Storage Range
Dimensions (approx.)
Weight (approx.)
TSR-301S
Liquid Crystal Display
4 Digits (1/10th of a degree increments)
89.6°F to 109.4°F (32.0°C to 43.0°C)
Oral, Axillary, and Rectal
°F or °C
± 0.2°F between 89.6°F and 109.4°F
(±0.1°C between 32.0°C and 43.0°C)
> 99.5°F (37.5°C) eight sets of three
quick beeps will sound
Four quick beeps will sound
TSP-001
SG3 Alkaline
Approximately 200 hours
Approximately after 10 minutes
Last temperature recall
Yes
41.0°F to 104.0°F (5.0°C to 40.0°C)
10% to 80% RH
14.0°F to 140.0°F (-10.0°C to 60.0°C)
10% to 80% RH
5.2" x 0.83" x 0.43"
0.47 oz including battery
Specifications are subject to change without notice.
Manufacturer's One Year
Limited Warranty
Manufa cturer will, at i ts option, repa ir or replace you r thermometer w ith
the same or c omparable model f or a period of one year f rom the date of
pur chase i n the eve nt of a defe ct in mate rials or w orkman ship. T he
warrant y only extends to th e original retai l purchaser. Purc hase receipt
or o the r pro of of o rig ina l pur ch ase i s req uir ed be for e war ran ty
perform ance.
This w arranty e xtends so lely to fai lures due t o defects i n materia ls or
wor kmansh ip occur ring dur ing norm al use. I t does not c over nor mal
wear o f the produ ct. This wa rranty is vo id if: the ho using pro duct has
been r emoved, if t he manufac turer's la bel, logo o r serial num ber have
been r emoved or i f the produ ct fails to f unction pr operly as a r esult of
ac cid ent , mis use , abu se, ne glec t, mis hand ling , misa ppl ica tio n,
defe ctive ba tterie s, fault y instal lation , set-up , adjust ments, im proper
mainten ance, alterati on, maladjustm ents of control, m odification, p ower
sur ges, com mercia l use of pr oduct, s ervice b y anyon e other th an an
authori zed service center o r acts beyond the man ufacturer's con trol.
This w arranty an d remedy pro vided here in are exclu sive and in li eu of
all oth er express an d implied war ranties and u nless state d herein, any
stat ements or r epresen tations ma de by any othe r person or en tity are
void . Neithe r the manuf acturer , distrib utor nor the ir affili ates shal l be
li able f or lo ss, in conv enie nce, i njur y, or da mage i nclu ding d irec t,
spec ial, inc idental , or conse quentia l damage s result ing from t he use,
impro per use, fail ure to heed any w arning, dis claimer, o r instruct ion or
in abil ity to u se thi s prod uct , whet her ar isi ng out o f bre ach of t his
warran ty or any other le gal theory. Al l express and im plied warran ties,
inclu ding the war ranties of m erchantib ility are lim ited to the ap plicable
warra nty period se t forth abov e. Manufac turer and dis tributor a ssume
no respo nsibility fo r injuries, da mages or penal ties incurre d or suffered
result ing from the use of th is product in an im proper manner o r location
othe r than for whi ch it is inten ded or from fa ilure to he ed any warni ng,
disclai mer, or instructio n.
SAMSUNG AMERICA, INC.
Printed in Taiwan
www.SamsungHealthcare.com
1.800.261.0130
Question or Comments:
105 Challenger Road 6th Fl.
Ridgefield Park, NJ 07660
1 2 3 4 5 6 7 8 9