•Tools needed for installation of the SaniSeat. (See page 1)
•How to install low voltage wiring and sensor cable behind wall. (See
page 2 & 2b)
•How to install surface mount with raceway. (See page 3 & 3b)
•Power supply mounting. (See page 4)
•Types of wall sensors. (See pages 5 to 7)
•Wall sensors (PCB chip) program functions. (See page 8)
•Battery, charger and tray. (See page 9)
•Mounting SaniSeat to bowl. (See page 10)
•Installation of new SaniWrap rolls. (See page 11)
•Replacing SaniSeat razor blades. (See page 12)
•How to clean & maintain SaniSeat.(See page 13)
•SaniSeat Swap-Out and Agreement. (See page 14 & 14b)
•Exploded view of SaniSeat.(See page 15)
•SaniSeat seat, box and case dimensions. (See page 16)
•Frequently asked SaniWrap questions. (See page 17)
•Reorder form. (See page 18)
•Contacts for sales and service. (See page 19)
•New items. (See page 20)
SaniSeat Surface Installation
Tools Needed:
•Phillips screwdriver with three inch long #0, #1 & #2 bits
•Slotted screwdriver
•Electric Drill
•Wire strippers
•9/16 deep socket & socket wrench
•Rubber gloves
•Anti-bacterial soap
•Clorox®Clean-Up wipes
SaniSeat Wall Installation
Tools Needed:
•Phillips screwdriver with three inch long #0, #1 & #2 bits
•Slotted screwdriver
•Wire strippers
•9/16 deep socket & socket wrench
•Rubber gloves
•Anti-bacterial soap
•Clorox®Clean-Up wipes
•Electric Drill
•13/4inch carbide hole saw with 3/16 carbide center bit
•16-18 gauge low voltage wire
•Electrical snakes
•Long drill bits
•14mm socket & 1/2inch socket
•WD-40 & food grade silicone by CRC (Available from North American Hygiene or
Grainger's Supply)
•Fox tail and dust pan
Page 1
OPTIONS FOR SaniSeat INSTALLATIONS
There are 4 basic types of SaniSeats installs
FLUSH MOUNT: (HARDWIRE FIG.1 OR BATTERY FIG.2)
Flush mounted installations have all wires snaked behind the wall and
PANDUIT is not necessary. SEE PAGE 2 For hardwire flush mount install
details.
SURFACE MOUNT:(HARDWIRE FIG. 3 OR BATTERY FIG. 4)
Surface mounted installations use PANDUIT, which is a brand name of a
raceway, tees, right angle’s, and junction boxes to run and hide all wires & cables;
it is fastened to the wall using double sided sticky tape. SEE PAGE 3 For battery
surface mount details.
Figure 1 Figure 2
Figure 3 Figure 4
Page 1b
Page 2
Top Hole: The eleven-pin connector on the sensor cable connects to the
wall hand sensor.
Bottom Hole: The four and five pin connectors connect to the stainless
steel gang plate. The two pin connectors connect to the blue and red
pigtail that feeds from the power supply in the ceiling.
Page 2b
Page 3
Figure 4
CONNECT THE
4 PIN MALE
CONNECTOR
TO THE 4 PIN
FEMALE
CONNECTO
R
CONNECT THE
5 PIN MALE
CONNECTOR
TO THE 5 PIN
FEMALE
CONNECTOR
STAINLESS
STEEL
GANG
PLATE
COVER
WITH SEAT
CABLE
SEAT IS NOW ACTIVE
Figure 3
CONNECT THE 2 PIN MALE TO THE
YELLOW & BROWN WIRE'S 2 PIN
FEMALE CONNECTORS
SENSOR IS NOW ACTIVE
WHITE / RIBBED
WIRE IS
NEGATIVE
RED / SMOOTH
WIRE IS
POSITIVE
RED/SMOOTH POSITIVE WIRE &
WHITE/RIBBED NEGATIVE WIRE
CONNECT TO THE 2 PIN MALE PIG
TAIL
,
(
AS SEEN IN FIG.2
)
Figure 1 Figure 2
2 PIN FEMALE
CONNECTOR
ON SENSOR
CABLE
2 PIN MALE
PIGTAIL
CONNECTOR
USE A WIRE NUT TO CONNECT THE
BLACK/BLUE PIGTAIL TO THE
WHITE/RIBBED WIRE.
USE A WIRE NUT TO
CONNECT THE RED
PIG TAIL TO THE
RED/SMOOTH WIRE
Page 3b
SaniSeat Universal Self-Regulating Power Supply
Power supply with mounting bracket & hardware.
Shown here installed above ceiling line:
Page 4
SaniSeatCOMBO WALL SENSOR
Sensors can be battery or hardwire operated.
Changing the toggle switch to the 'up' position sets the sensor to
battery; the 'down' position sets the sensor to hardwire.
TOGGLE
SWITCH
Page 5
SaniSeat Flush and Surface Mounted
Hard-Wired Wall Sensors
FLUSH MOUNTED SENSOR COMES WITH LV-2 MOUNTING PLATE
(See page 7 for specifications of LV-2 mounting plate.)
SURFACE MOUNTED SENSOR
(Shown with seat and sensor hardware.)
Page 6
Lv2 Mounting Plate
Lv-2 Mounting Plate is included with the flush mounted SaniSeat wall
sensor.
The Lv-2 Mounting Plate fits walls from 1/4" to 1" thick. Rough opening
measurements are shown below
Page 7
Page 7
R.O.
3 11/16"
R.O. 3 11/16"
Sensor Programming
Reactivation: For 19 seconds after completing a spin the
wall sensor is inactive.
Ignore: Usensor will ignore any color or shadow for
the first 1.5 seconds of a spin.
Time Out: Motor will run for a maximum of 9 seconds,
this is a precaution for incorrectly loaded
SaniWrap or U sensor malfunction.
Page 8
Top View
SaniSeat
Rechargeable Batteries and Charging Trays
3800 mAh Nickel Metal Hydride Battery
To Recharge:
Place battery with the contacts held over the internal charger pins, then
gently push down to make contact with pins. Charging will start within 3
seconds, when the red LED begins to blink.
Charge times will vary from 4 to 12 hours, depending on how low the
battery was. When the battery is totally charged, the green LED will light
up & stay on.
Once the battery is fully charged, we recommend that you remove it from
the charger. If the battery is not removed it goes into a ‘trickle’ charge,
which over time will shorten the life cycle of the battery.
New Horizontal Charger And Tray
For more info on LED functions see page 9b.
Page 9
SaniSeat Charger Functions
To set up charger tray:
First plug the chargers small female barrel end cable into the tray,
then plug the power cord into the wall outlet, the small green rectangle
light will light up & power the tray.
SaniSeat Charging Tray LEDFunctions
RED LED is solid when the charger is plugged in and empty.
RED LED blinks after 3 seconds if battery is taking the charge.
YELLOW LED will only come on if battery is under 2vdc and needs
a kick charge, if the battery accepts the kick charge within 10 minutes the
YELLOW LED will go off & the RED LED will blink & charging will
start. If the battery does not accept the kick charge then the RED LED
comes on & stays solid, that indicates that there is a bad cell in the
battery or the battery is old & cycled out.
GREEN LED becomes a solid green light when the battery reaches its full
charge which is about 14 vdc to 14.40 vdc.
As stated before, on previous page, please take the battery out of the tray
when charging is finished to increase the battery’s life cycles.
The SaniSeat batteries have a minimum of 500 rechargeable cycles at
14.vdc after that each cycle starts to degrade slightly.
Page 9b
Mounting the SaniSeat to the toilet bowl
All hardware needed to mount the SaniSeat to the toilet bowl can be found in the wall
sensor box. You will find two metal plates, two 11/2'' bolts with tapered and regular washers,
and 9/16'' nuts. You will also find the keys for the locking lid, yellow nylon anchors and
screws, however you will not need them until later in the installation process when mounting
the Wall Sensor and gang plate to the wall.
1. The original seat should be removed leaving
just the porcelain bowl. 5. Take the two 11/2'' bolts and place them
through the metal plate slots and in the bowl's
bolt holes.
2. Place the SaniSeat on the bowl so that the
metal bracket is over the boltholes. 6. In one hand hold a tapered and metal washer,
along with a 9/16'' nut.
3. Take both metal plates from the sensor box
and lift seat so bracket is easily visible.
7.
4. Place the metal plates in the bracket channel
so the bolt holes are visible.
Before threading arrangement onto the bolt,
keep constant downward pressure on the bolt.
NOTE: The plastic washer should be against
porcelain.
Page 10
Page 11
Installation of New SaniWrap Rolls
1. Remove used spool from left chamber by
pulling back on the stainless steel spring
clip (As shown in Figure 3). Discard used
Spool.
2. Before loading the new SaniWrap roll,
make sure the seat rin
g
is clean and dr
y
. If
not, spray Clorox®Cleanup (or similar
product) to the top and bottom of the seat
ring and dry with a soft cloth. As an extra
measure of preventative maintenance, you
may spray food grade silicon on the top
and bottom of the seat ring and allow to
dry for 30-seconds. (Food
g
rade silicon can
be purchased from North American
H
yg
iene, Inc.) You are now read
y
to install
the new SaniWrap roll.
3. The empty spool in the right chamber
becomes the new take-up spool in the left
chamber. NOTE: When installing the
empty spool in the left side chamber, flip
in over so that the narrow end with the
slot is facing the motor (As shown in
Figure 3). Release the spring clip to lock
the take-up spool in place.
4. Insert a new roll of SaniWrap in the ri
g
ht
side chamber. Make sure the SaniWrap
dispenses from the bottom of the roll and
travels under the U-Bar.
5. Slide SaniWrap completely around the
seat ring, past the razor blade and onto the
take-up spool.
6. Press the 200-use button 2 times on the top
of the motor housing to indicate roll size.
The LED display of the Wall Sensor will
read 150 and automatically countdown the
number of uses left on the clean SaniWrap
roll.
7. Activate the seat by placing your hand in
front of the Wall Sensor to make sure that
the SaniWrap roll is properly installed.
Replacing a SaniSeat Razor Blade
Before starting you should have a Phillips head screwdriver, 14mm
socket wrench and a replacement blade with short screw.
WARNING: New and Used SaniSeat razor blades are extremely sharp and
should be handled with caution.
1. Using your 14mm socket wrench,
remove the two bolts located on the
left side of the seat.
2. After removing the bolts, the seat
ring should easily pull from the
seat base.
3. Turn the seat ring over and remove
the used razor blade by using the
Phillips head screwdriver. After
doing so replace with the new razor
blade and short screw
4. Secure the seat ring back to the
seat base using the two bolts
removed in step 1. Be sure to
thread the bolts through the metal
plate attached to the braided cable
when tightening.
Page 12
Three Easy Steps to a Clean SaniSeat
To keep your SaniSeat running at optimal performance we recommended
using Clorox®Clean Up:
Recommended Cleaning Procedures:
The best time to clean a SaniSeat is while changing the roll of SaniWrap.
This should be the only time that all the SaniWrap is removed from the seat.
Once the SaniSeat is clear of any SaniWrap follow our three steps to a clean
seat.
1. Spray Clorox®Clean Up over all infected areas, making sure not to forget
about the seat ring.
2. Let stand for a couple seconds before wiping clean.
3. Before any SaniWrap is put back on the SaniSeat, make sure the seat ring
is completely dry. Any moisture on the seat ring will cause drag and added
strain to the motor.
To create a slick and efficient surface for the SaniWrap to slide along the seat
ring, spray Food Grade Silicone by CRC to either side of the ring before
spooling a new roll of SaniWrap.
You can order a can of Food Grade Silicone by CRC from us along with
your next SaniWrap order, or from your local Grainger Supply.
Page 13
Replacement of SaniSeat (Swap-Out)
Before starting you should have a Phillips head screwdriver.
1. Remove the screen and white washers
holding the seat to bracket. 2. Remove the two screws from the gang
plate.
3. After the screws are removed from the
gang plate, gently pull on the braided
cable to expose the black quick-release
clips. Release the small tab and separate
by holding each side of the plastic clip.
NOTE: When separating clips do not
pull by the wires alone.
4. With all screw removed and clips
disconnected, the seat should easily lift
from the bracket. You are now ready to
attach the replacement seat.
Page 14

This manual suits for next models

1

Popular Toilet manuals by other brands

Thetford C-200 series instructions

Thetford

Thetford C-200 series instructions

Luxart LX750 INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

Luxart

Luxart LX750 INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

Toto NEOREST A Installation instruction

Toto

Toto NEOREST A Installation instruction

Toto AP WASHLET CWT4263084CMFG quick start guide

Toto

Toto AP WASHLET CWT4263084CMFG quick start guide

Ideal-Standard Alto Toilet Seat installation guide

Ideal-Standard

Ideal-Standard Alto Toilet Seat installation guide

STUDIOLUX SLi5200 manual

STUDIOLUX

STUDIOLUX SLi5200 manual

Roca MULTICLEAN PREMIUM A80400800 manual

Roca

Roca MULTICLEAN PREMIUM A80400800 manual

Sanela 94090 Mounting instructions

Sanela

Sanela 94090 Mounting instructions

Toto Washlet E200 installation instructions

Toto

Toto Washlet E200 installation instructions

Lippert Flow Max RV installation guide

Lippert

Lippert Flow Max RV installation guide

Woodbridge BID 02 installation manual

Woodbridge

Woodbridge BID 02 installation manual

Kohler ADAIR K-8699T installation instructions

Kohler

Kohler ADAIR K-8699T installation instructions

Clesana C1 Series installation instructions

Clesana

Clesana C1 Series installation instructions

DXV Equility D22690A109 installation instructions

DXV

DXV Equility D22690A109 installation instructions

Porcelanosa Noken URBAN C 100160146 N369225479 manual

Porcelanosa

Porcelanosa Noken URBAN C 100160146 N369225479 manual

Drive Dupont TALIS operating instructions

Drive

Drive Dupont TALIS operating instructions

American Standard LOVEN TF-2033 installation manual

American Standard

American Standard LOVEN TF-2033 installation manual

Reece Laufen Pro A 1813059 installation instructions

Reece

Reece Laufen Pro A 1813059 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.