Santa Fe Advance2 User manual

For small usage:
4201 Lien Rd., Madison, WI 53704 •TOLL-FREE 1-800-533-7533 •www.Santa-Fe-Products.com
Designed for Basement and Crawlspace Dehumidification
nHigh capacity
nHigh efficiency
nEnvironmentally friendly
nPatent pending dual-air distribution
INSTALLER’S & OWNER’S MANUAL
P/N 4034180 • Serial No.________________________ Install Date:___________
Sold by:
Patent Pending Dual-Air Distribution

Table of Contents
1. Intended Application(s) ................................................... 2
2. Registration ................................................................... 2
3. Specications ............................................................ 3
4 . Installation .................................................................... 3
4.1 Remove Compressor Shipping Support...................... 3
4.2 Location .................................................................... 3
4.2A No Ducting ............................................................ 3
4.2B Duct Outlets .......................................................... 3
4.2C Remote Area w/Outlets Ducted ............................. 3
4.3 Electrical Requirements ............................................. 4
4.4 Install Leveling Feet ................................................... 4
4.5 Condensate Water Removal ....................................... 4
5. Ducting .......................................................................... 4
5.1 Outlet Duct Kit ........................................................... 4
6. Operation ....................................................................... 4
6.1 Humidity Control Adjustment ..................................... 4
6.2 Fan Switch ................................................................ 4
Installation
7. Maintenance .................................................................. 5
7.1 Air Filter..................................................................... 5
8. Service .......................................................................... 5
8.1 Technical description ................................................. 5
8.2 Troubleshooting ......................................................... 5
8.3 Defrost Thermostat .................................................... 6
9. Service Parts List ........................................................... 6
10. Accessory/Replacement Parts List ............................... 6
11. Wiring Diagram ............................................................ 6
Warranty ............................................................................ 7
Precautions
• Do not operate the Santa Fe™ Advance2 with a cut or
frayed power cord.
• Do not unplug the unit by pulling on the cord. Grasp the
plug rmly and pull it out of the wall socket or power
receptacle.
• Always use a grounded outlet.
• Never operate electrical equipment near or in standing
water.
• Do not stick your ngers or other objects through the safety
grill.
• When changing lters, do not stick ngers or other objects
in the unit.
• No user serviceable components. Contact installer or call
1-800-533-7533, Ext. 8459 for all repair or warranty needs.
• Do not restrict airow in to or out of the unit. This may
cause the unit to overheat.
• The unit should never be serviced or cleaned while it is
plugged in.
• Do not sit or stand on the unit, or use as a shelf or table.
• Before leaving the unit unattended, ensure children do not
have access to the equipment. Do not allow children to play
with or near the unit or in its air ow.
• The unit is designed to be installed indoors only.
Read the installation, operation and maintenance
instructions carefully before installing and using
this unit. Proper adherence to these instructions is
essential to obtain maximum benefit from your Santa Fe
Advance2 dehumidifier.
Read and Save These Instructions
WARNING! — This symbol means important
instructions. Failure to heed them can result in serious
injury or death.
CAUTION! — This symbol means important
instructions. Failure to heed them can result in injury or
material property damage.
1. Intended Application(s)
The Santa Fe Advance2 is intended for use in crawlspaces
or basements: however, the unit can be placed in almost
any residential setting where dehumidication is desired.
Use in non-residential applications and pool areas may
void warranty.
The Santa Fe Advance2 works most effectively between 56°
and 95°.
In order to efciently control humidity levels, the area in
which the dehumidier is to be operated must be free of
water intrusion or excessive fresh (outside) air inltration.
Before installing the Santa Fe Advance2, water intrusion and
air inltration problems should be addressed.
2. Registrations
The Santa Fe Advance2 conforms to UL STD 1995.
TABLE OF CONTENTS
2Santa Fe Advance2 Installer’s & Owner’s Manual

3. Specifications
Part Number: 4034180
Blower: 309 CFM @ 0.0" WG
Power: 640 Watts @ 80°F and 60% RH
Supply Voltage: 115 volt – 1phase – 60 Hz
Current Draw: 5.7 AMPS
Energy Factor: 3.0 L/kWh
Operating Temp.: 56°F Min., 95°F Max.
Sized for: 2200 Sq. Ft. - Typical
Performance at 80°F and 60% RH
Water Removal: 90 Pints/Day
Efciency: 6.4 Pints/kWh
Air Filter: MERV-8
Size: 14" x 17.5" x 2"
Power Cord: 10', 110-120 VAC, Ground
Drain Connection: 3/4" Threaded NPT or 5/8" Hose Barb
Dimensions Unit Shipping
Width: 14.5" 19"
Height: 19.4" 25"
Depth: 26" 35"
Weight: 80 lbs 90 lbs
4. Installation
4.1 Remove Compressor Shipping Support
The Santa Fe Advance2 uses a
compressor to power the refrigeration
system. To protect the compressor
and refrigeration system during
shipping a plastic tie wrap secures
it to the units frame. Remove the
tie wrap by cutting the tie wrap and pulling from the unit as
shown. After removing tie wrap, insert plastic plugs provided
into the holes.
4.2 Location
The Santa Fe Advance2 can be installed in a variety of locations
to meet the owner’s needs; other considerations include:
1. Providing access to a 115 VAC power outlet (10'
power cord is provided).
2. Locating near a oor or other suitable drain.
3. Mount 4" above drain.
4. Do not install the Santa Fe Advance2 with
the exhaust of the unit within 1' of a wall or
obstruction. Do not place the unit near open water.
4.2A No Ducting (Figure 1)
The simplest installation is to place the Santa Fe Advance2
with no ducting. To ensure optimal performance, the air inlet
and the outlet of the unit must be at least 1' from walls and
other obstructions to air ow.
4.2B Duct Outlet (Figure 2)
Dehumidification performance can be modified by adding an
outlet duct to circulate air.
4.2C Remote Area, w/Outlets Ducted (Figure 3)
A simplied remote installation method than above uses
ducting between the Santa Fe Advance2 discharge and the
humid room; the Santa Fe Advance2 inlet draws air from
the room in which it’s located. This works well if there is an
adequate air ow path between the two rooms; e.g. high door
undercut, louvered door or wall grill. This eliminates the need
to remote mount the humidity control.
SANTA FE ADVANCE2 OWNER’S AND INSTALLER’S MANUAL
3Santa Fe Advance2 Installer’s & Owner’s Manual
Input of
Humid Air
Output of
Dehumidified Air
Front View
Input of
Humid Air
Output of
Dehumidified Air
Front View Figure 2: Installation in humid area
with outlet ducting
Figure 1: Installation with no ducting.
CONDITIONED SPACE
Input of
Humid Air
Output of
Dehumidified Air
Figure 3:
Installation in
a remote area
with ducted
outlets

WARNING!
4.2 Electrical Requirements
The Santa Fe Advance2 plugs into a common grounded outlet
on a 110-120 VAC 15-Amp circuit. While operating, it draws
less than 6 amps @ 80°F, 60% RH and less than 5.5 amps @
75°F, 50% RH. Use of a ground fault circuit interrupter (GFCI)
protected circuit is recommended. The unit should not be used
in areas prone to ooding.
4.3 Installing Feet
Included with your Santa Fe
Advance2 are four leveling feet.
It is important to level the unit
for proper draining.
Installing Leveling Feet
See Figure 2 for installing leveling feet.
1. Lay down a protective pad (pillow, blanket, etc.).
2. Carefully turn unit onto side opposite drain port.
3. Align leveling foot shaft with one of the four threaded
hole locations as shown in Figure 2.
4. Screw each leveling foot in ten revolutions.
5. Carefully bring unit to upright position.
6. Level unit for proper water drainage.
7. Wait 10 minutes before operating.
CAUTION!
Note: Operating the unit immediately after bringing it to an
upright position can possibly damage the compressor. A short
amount of time is needed (10 minutes) to allow the oil to
return to it’s reservoir for lubrication.
CAUTION! For proper drainage, the
unit must be mounted so the drain outlet is at
least 4" above the floor drain, and must be fully
supported under the base.
4.4 Condensate Water Removal
The Santa Fe Advance2 drains via a gravity system - it is not
able to push condensate (water) uphill. The drain hose must
run downhill toward the drain location. Condensate can be
drained by using the 5/8" clear hose and adapter provided,
or by using a male 3/4" NPT PVC pipe. Using either option,
care must be taken installing adaptor to the drain port. Use
standard condensate drain routing practices outlined when
routing the drain line.
Be sure the hose is not kinked or otherwise restricted so that
water can pass through it. Improper hose installation may
result in water leakage.
To increase the efciency of the unit, position the hose to
create a “trap” as shown in Figure 3. By creating a trap, it will
hold a small amount of water. Position the trap on the hose
approximately 12" to 20" away from the unit. Check hose
regularly to ensure it is clear and water is draining properly.
If oor drain is not
easily accessible, a
condensate pump
kit with a 20' hose is
available. Contact your
dealer or order online if
you are interested in ordering the pump.
CAUTION! Remove compressor shipping
tie from the unit. Failure to remove shipping tie
will cause excess vibration to be transmitted to
the frame.
5. Ducting
5.1 Duct Kit (P/N 4033039)
A factory designed outlet duct kit can be purchased to
accept 10" ducting to both outlets of the Santa Fe Advance2.
Contact your dealer or order online.
6. Operation
6.1 Humidity Control Adjustment
The humidity control is an adjustable switch that closes when
the relative humidity of the air in which it is located rises to
the dial set point. It opens when the RH drops 4 to 6% below
the set point.
Approximate Humidity Levels Per Setting:
“Drier” 20% to 30% Relative Humidity
“Normal” 45% to 55% Relative Humidity
(Recommended)
“Humid” 80% to 90% Relative Humidity
SANTA FE ADVANCE2 OWNER’S AND INSTALLER’S MANUAL
4Santa Fe Advance2 Installer’s & Owner’s Manual
Figure 1: Four leveling feet
Figure 2: Insert leveling feet
in locations
4031882
Auto
On

The dehumidier will run until the relative humidity (RH) is
reduced to the humidity control dial setting.
Quality humidity meters are available from the factory and
are recommended to accurately monitor humidity levels.
Refer to the options and accessories table in this document.
6.2 Fan Switch
Turning the impeller switch to “FAN ON” will cause the unit’s
internal impeller to run continuously, whether the unit is
dehumidifying or not. This function is desirable if the unit is
used for air circulation.
Turning the fan switch to “FAN AUTO” will cause the unit’s
internal blower to run only while the unit is dehumidifying.
7. Maintenance
CAUTION! NOTE: Do not operate the unit
without the filter or with a less effective filter. The
heat exchange coils inside the unit could become
clogged and require disassembly to clean.
7.1 Air Filter
The Santa Fe Advance2 ships with a standard MERV 8
pleated fabric filter. This should be checked every six
months. The pleated fabric lter can generally be vacuumed
clean several times before needing replacement. Operating
the unit with a dirty filter will reduce dehumidifier capacity
and efficiency and may cause the compressor to cycle on
and off unnecessarily. Replacement filters can be ordered
from your dealer or by calling 1-800-533-7533.
8. Service
WARNING! Servicing the Santa Fe
Advance2 with its high pressure refrigerant
system and high voltage circuitry presents a
health hazard which could result in death, serious
bodily injury, and/or property damage. Only
qualified service people should service this unit.
8.1 Technical Description
The Santa Fe Advance2 uses a refrigeration system similar
to an air conditioner’s to remove heat and moisture from
incoming air, and add heat to the air that is discharged. Hot,
high pressure refrigerant gas is routed from the compressor
to the condenser coil. The refrigerant is cooled and
condensed by giving up its heat to the air that is about to be
discharged from the unit. The refrigerant liquid then passes
through a filter/drier and capillary tubing which cause the
refrigerant pressure and temperature to drop. It next enters
the evaporator coil where it absorbs heat from the incoming
air and evaporates.
Santa Fe Advance2 refrigeration system
The evaporator operates in a ooded condition, which
means that all the evaporator tubes contain liquid
refrigerant during normal operation. A ooded evaporator
should maintain constant pressure and temperature across
the entire coil, from inlet to outlet. The mixture of gas and
liquid refrigerant enter the accumulator after leaving the
evaporator coil. The accumulator prevents any liquid
refrigerant from reaching the compressor. The compressor
evacuates the cool refrigerant gas from the accumulator
and compresses it to a high pressure and temperature gas
to repeat the process.
8.2 Troubleshooting
FOR THE HOMEOWNER:
n If the unit does not work properly, please check the
following:
— Is the unit unplugged?
— Is power to outlet on? (check switch, if applicable)
— Is circuit breaker tripped?
— Is humidity control set? (turn to “ON”)
— Is air flow restricted? (check air filters and grill)
If none of the above, call dealer or 1-800-533-7533,
Ext. 8459.
FOR THE HVAC PROFESSIONAL:
n No dehumidification. Neither blower, nor compressor run
with fan switch AUTO.
1. Unit unplugged or no power to outlet, circuit breaker
tripped.
2. Humidity control set to “Humid” setting.
3. Loose connection in internal wiring.
4. Humidity control is defective.
SANTA FE ADVANCE2 OWNER’S AND INSTALLER’S MANUAL
5Santa Fe Advance2 Installer’s & Owner’s Manual

n No dehumidification. Compressor does not run but
blower runs with fan switch AUTO and humidity control
turned to ON.
1. Defrost thermostat open, ambient temperature too low.
2. Loose connection in compressor circuit.
3. Defective compressor overload.
4. Defective compressor or compressor run capacitor.
n Blower runs with fan switch AUTO but compressor
cycles on & off.
1. Low ambient temperature and/or humidity causing unit
to cycle through defrost mode.
2. Defrost thermostat defective.
3. Defective compressor overload.
4. Defective compressor.
n Blower does not run with fan switch in either position.
Compressor runs briefly but cycles on and off.
1. Loose connection in blower circuit.
2. Obstruction prevents impeller rotation.
3. Defective blower.
4. Defective blower switch.
n Evaporator coil frosted continuously, low
dehumidifying capacity.
1. Dirty air lter or air ow restricted.
2. Defrost thermostat loose or defective.
3. Low refrigerant charge.
If none of the above has fixed the issue, call
technical support at 1-800-533-7533, Ext. 8459.
9. Service Parts List -
Call your dealer or 1-800-533-7533.
Part No Description
4034011-02 Evaporator
4034093 Capillary Tubes
4028089 Compressor
1970010 Compressor Relay
4029510 Filter/drier
4034109 Condensor
4032196 Impeller
4033032-03 35mfd 370V Capacitor - Compressor
4033031-02 5mfd 370V Capacitor - Impeller
4026221 Leveling Foot
4031376 Defrost Thermostat
4027172 Humidity Controller
4025560 Fan Switch
SANTA FE ADVANCE2 OWNER’S AND INSTALLER’S MANUAL
6Santa Fe Advance2 Installer’s & Owner’s Manual
11. Wiring Diagram
10. Accessory/Replacement Parts -
Call your dealer or order online.
4031062 Filter MERV 8
4033036 Filters 4-Pack, MERV 8
4033037 Filters 12-Pack, MERV 8
4028616 Caster Kit
4033038 Pump Kit
4033039 Duct Kit
4026969 10" Flex Duct
4022126 10" Flex Duct (Insulated)
4020175 Remote Dehumidistat

Limited Warranty
Limited Warranty. Therma-Stor, LLC (“Therma-Stor”) warrants
as follows: (i) the Santa Fe Advance2 dehumidifier (“Product”) will
be free of material defects in workmanship or materials for a period
of one (1) year (“One-Year Warranty”) following the date of initial
purchase of such Product by an original customer purchasing from
Therma-Stor or an authorized reseller (“Customer”); and (ii) the
Product’s condenser, evaporator, and compressor will be free of
material defects in workmanship or materials for a period of five
(5) years following the date of initial purchase of such Product by a
Customer.
Limitation of Remedies. CUSTOMER’S SOLE AND EXCLUSIVE
REMEDY UNDER THE ABOVE LIMITED WARRANTY AND THERMA-
STOR’S ENTIRE LIABILITY THEREUNDER, SHALL BE, AT THE SOLE
OPTION OF THERMA-STOR, REPLACEMENT OR REPAIR OF SUCH
PRODUCT OR ITS COMPONENTS (“COMPONENTS”) BY THERMA-
STOR OR THERMA-STOR’S AGENTS ONLY. REFRIGERANT, PIPING,
SUPPLIES, TRANSPORTATION COSTS, LABOR COSTS INCURRED
IN REPAIR OR REPLACEMENT OF SUCH COMPONENTS ARE NOT
INCLUDED. THIS DISCLAIMER AND EXCLUSION SHALL APPLY
EVEN IF THE EXPRESS WARRANTY AND LIMITED REMEDY SET
FORTH HEREIN FAILS OF ITS ESSENTIAL PURPOSE. CUSTOMER
ACKNOWLEDGES THAT NO REPRESENTATIVE OF THERMA-STOR OR
OF ITS AFFILIATES OR RESELLERS IS AUTHORIZED TO MAKE ANY
REPRESENTATION OR WARRANTY ON BEHALF OF THERMA-STOR
OR ANY OF ITS AFFILIATES OR RESELLERS THAT IS NOT IN THIS
AGREEMENT. Notwithstanding the above, during the term of the
One-Year Warranty only, Therma-Stor will provide, free of charge to
Customer, all Components and labor (except costs related to removal
and installation of Product) required to fulfill its obligations under such
One-Year Warranty.
Disclaimer of Warranties. EXCEPT FOR ABOVE LIMITED
WARRANTY, WHICH IS THE SOLE AND EXCLUSIVE WARRANTY
PROVIDED WITH RESPECT TO THE PRODUCT AND ITS COMPONENTS,
THERMA-STOR HEREBY DISCLAIMS ALL EXPRESS AND IMPLIED
WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
Warranty Limitations. The foregoing limited warranty extends only
to a Customer and shall be null and void upon attempted assignment
or transfer. A “defect” under the terms of the limited warranty shall
not include problems resulting from Customer’s or Customer’s
employees’, agents’, invitees’ or a third party’s misuse, improper
installation, improper design of any system in which the Product
is included, abuse, lack of normal care, failure to follow written
instructions, tampering, improper repair, or freezing, corrosion, acts
of nature or other causes not arising out of defects in Therma-Stor’s
workmanship or material. If a Product or Component is replaced
while under warranty, the applicable limited warranty period shall
not be extended beyond the original warranty time period. The
limited warranty does not cover any costs related to changes to a
Product or Component that may be required by any codes, laws, or
regulations that may become effective after initial purchase of the
Product by Customer.
Customer Responsibilities. As a further condition to obtaining
warranty coverage hereunder, the Customer must send a valid
warranty claim to Therma-Stor such that Therma-Stor receives
such claim prior to the end of the applicable warranty period.
Therma-Stor shall have no obligation hereunder with respect to
any claim received by Therma-Stor after the expiration of the
applicable warranty period. As a further condition to obtaining
warranty coverage hereunder, the Customer must present forms of
invoices evidencing proof of purchase of a Product. If such invoices
do not clearly indicate the date of initial purchase by a Customer,
the applicable Product’s date of manufacture will be used instead
of the date of initial purchase for the purpose of calculating the
commencement of the applicable warranty period. Warranty service
must be performed by Therma-Stor or a servicer authorized by
Therma-Stor. In order to obtain warranty service, the Customer
should call Therma-Stor at 1-800-533-7533 and ask for the
Therma-Stor Products Service Department, which will then arrange
for applicable warranty service. Warranty service will be performed
during customary, daytime working hours. If the Product must be
shipped for service, Customer shall be solely responsible for properly
packaging the Product, for all freight charges, and for all risk of loss
associated with shipment.
Limitation of Liability. IN NO EVENT SHALL THERMA-STOR,
IN CONNECTION WITH THE DESIGN, SALE, INSTALLATION, USE,
REPAIR, REPLACEMENT OR PERFORMANCE OF ANY PRODUCT,
COMPONENT, PART THEREOF OR WRITTEN MATERIAL PROVIDED
THEREWITH, BE LIABLE, TO THE EXTENT ALLOWED UNDER
APPLICABLE LAW, UNDER ANY LEGAL THEORY FOR ANY SPECIAL,
DIRECT, INDIRECT, COLLATERAL OR CONSEQUENTIAL DAMAGES
OF ANY KIND. NOTWITHSTANDING THE ABOVE LIMITATIONS AND
WARRANTIES, THE SOLE AND EXCLUSIVE LIABILITY OF THERMA-
STOR, REGARDLESS OF THE NATURE OR THEORY OF THE CLAIM,
SHALL UNDER NO CIRCUMSTANCES EXCEED THE PURCHASE PRICE
OF THE PRODUCT, COMPONENT OR PART UPON WHICH THE CLAIM
IS PREMISED.
Applicable Law and Venue. ANY ARBITRATION, ENAdvance2MENT
OF AN ARBITRATION OR LITIGATION RELATED TO THE PRODUCT
WILL BE BROUGHT EXCLUSIVELY IN DANE COUNTY, WISCONSIN,
AND CUSTOMER CONSENTS TO THE JURISDICTION OF THE
FEDERAL AND STATE COURTS LOCATED THEREIN, SUBMITS TO
THE JURISDICTION THEREOF AND WAIVES THE RIGHT TO CHANGE
VENUE. CUSTOMER FURTHER CONSENTS TO THE EXERCISE OF
PERSONAL JURISDICTION BY ANY SUCH COURT WITH RESPECT TO
ANY SUCH PROCEEDING.
Miscellaneous. If any term or condition of this Limited Warranty
is found by a court of competent jurisdiction to be invalid, illegal or
otherwise unenAdvance2able, the same shall not affect the other
terms or conditions hereof or thereof or the whole of this Limited
Warranty. Any delay or failure by Therma-Stor to exercise any right
or remedy will not constitute a waiver of Therma-Stor to thereafter
enAdvance2 such rights.
7

1-800-533-7533. | www.santa-fe-products.com
Other manuals for Advance2
1
Table of contents