Satel CZ-EMM3 User manual

CZ-EMM3 / CZ-EMM4
PROXIMITY CARD READER
cz-emm34_en 12/19
CZ-EMM3 / CZ-EMM4 reader is designed to read the unique codes of the users' proximity
cards. The reader can be connected to:
INT-R universal expander for card / iButton readers (if used as the CA-64 SR expander),
ACCO-KP / ACCO-KP-PS / ACCO-KPWG / ACCO-KPWG-PS access control module,
another access control device that supports the EM-Marin / Wiegand 26 / Clock & Data
format.
1. Features
Support for cards, tags and other 125 kHz passive transponders.
Data format: EM-Marin / Wiegand 26 / Clock & Data.
Two LEDs.
Built-in sounder
Bell key for control of the reader OC type output (BELL). [CZ-EMM4]
Suitable for indoor or outdoor installation.
2. Description

2 CZ-EMM3 CZ-EMM4 SATEL
Design
The electronic circuit is potted in epoxy resin for protection against moisture and dust. The
multi-conductor cable is led-out of the reader enclosure.
Data format
The reader can transmit data using one of the formats below:
EM-Marin (used for communication with the SATEL devices)
Wiegand 26
Clock & Data
You can select the data format during configuration of the reader.
Signaling
The LED indicators and audible signal are controlled by the device the reader is connected
to. When configuring the reader, you can define whether the signaling control inputs are to be
high level (5...12 V) or low level (0 V) sensitive.
The reader has two LEDs: red and green.
Bell key [CZ-EMM4]
The bell key controls directly the BELL output of the reader. The BELL output is an OC type
low-current output. Pressing the key will short the output to the common ground.
3. Installation
The device should be installed by qualified personnel.
Disconnect power before making any electrical connections.
The detector can be installed indoors as well as outdoors.
If the reader is installed on a metal surface, the card reading range will be reduced.
Two readers connected to the same device can work when situated a short distance
from each other. However, the distance from a reader connected to another device or
a device with built-in reader (e.g. a keypad with reader) should be at least
50 centimeters.
If you need an extra cable to make the connections, use an unshielded non-twisted cable.
The total length of the cable connecting the reader to the device should not exceed
30 meters.
1. Open the reader enclosure.
2. Place the enclosure base against the wall and mark the location of mounting holes.
3. Drill holes for wall plugs (anchors) in the wall.
4. Make a hole in the wall for the reader cable and run the cable through it.
5. Using wall plugs (anchors) and screws, secure the enclosure base to the wall. Select wall
plugs specifically intended for the mounting surface (different for concrete or brick wall,
different for plaster wall, etc.).
6. Close the enclosure and secure it with the screw.
7. If the reader is NOT to be connected to a SATEL device, configure the reader settings
(see “Configuring” p. 3).

SATEL CZ-EMM3 CZ-EMM4 3
8. Connect the wires to the device screw terminals according to the table below. The purple
wire (BELL output) you can connect e.g. to the control panel zone / access control module
input.
SATEL device terminal
Wire Description Reader A Reader B
Designation for
Wiegand 26 /
Clock & Data
red power +GA +GB +12V
green data (0) SIGA /
SIG1A
SIGB /
SIG1B OUT0/DATA
black data (1) do not connect OUT1/CLOCK
blue common ground COM COM COM
yellow sounder BPA BPB BEEP
pink green LED LD1A LD1B LED-G
gray red LED LD2A LD2B LED-R
brown blocking reader
operation DISA DISB HOLD
white presence control TMPA TMPB TMP
purple OC type output
(BELL) [CZ-EMM4] do not connect BELL
4. Configuring
The reader having the factory default settings is ready to work together with SATEL devices
and requires no configuration. The default settings are as follows:
data format: EM-Marin,
reader inputs are high level (5...12 V) sensitive. This setting applies to all inputs of the
reader (sounder, green LED, red LED and blocking reader operation).
If a change in these settings is required by the device to which you want to connect the
reader, you must follow the procedure below.
1. Disconnect all the reader wires from the device (if the reader is connected to the device).
2. If you want to change the settings of reader inputs:
the inputs are to be low level (0 V) sensitive – connect the pink wire to the common
ground terminal of the device,
the inputs are to be high level (5…12 V) sensitive – leave the pink wire disconnected.
3. Connect the brown and green wires together.
4. Connect the power to the red (+12V) and blue (COM) wires. After power on:
you will hear 4 short beeps and 1 long beep,
settings of the reader inputs will be saved,
LEDs will indicate the currently selected data format:
red LED flashing – EM-Marin,
green LED flashing – Wiegand 26,
both LEDs flashing – Clock & Data.

4 CZ-EMM3 CZ-EMM4 SATEL
5. If you want to change the data format, use the proximity card. Presenting the card to the
reader will each time change the data format, which will be indicated by the LEDs.
6. Power the reader off to finish the configuration procedure.
5. Using
Present the card to the reader so that the reader can read the card code. The card code will
be sent to the device to which the reader is connected. That device will decide what function
to run.
In case of EM-Marin format, the device to which the reader is connected can distinguish
between presenting the card (one-time reading the card code) and holding the card (the card
must be held in front of the reader for about 3 seconds, and its code will be read repeatedly
during that time). Another function can be activated by presenting the card, and another by
holding it.
The way the visual (LED) and audible (sounder) signaling works depends on the device to
which the reader is connected.
6. Specifications
Supply voltage .................................................................................................... 12 VDC ±15%
Maximum current consumption ....................................................................................... 80 mA
Reader transmit frequency........................................................................................... 125 kHz
BELL output, OC type [CZ-EMM4]................................................................... 30 mA / 12 VDC
Operating temperature range...............................................................................-20°C...+55°C
Maximum humidity ..........................................................................................................93±3%
Dimensions ................................................................................................... 47 x 158 x 24 mm
Weight
CZ-EMM3.........................................................................................................315 g
CZ-EMM4.........................................................................................................287 g
The declaration of conformity may be consulted at www.satel.eu/ce
SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu
This manual suits for next models