CZ-EMM2 SATEL
3
Designation of control
device terminals
Cable color Function Head A Head B
red head power supply +GA +GB
blue ground COM COM
green data SIGA SIGB
brown head operation blocking (where the heads
operate in close vicinity to each other, to
eliminate mutual interference) DISA DISB
gray red LED control LD2A LD2B
pink green LED control LD1A LD1B
yellow buzzer control BPA BPB
white presence control (tamper) TMPA TMPB
Table 1. Connection of CZ-EMM2 reader cables to control device terminals.
Note: The terminals designated TMPA and TMPB appear on the electronics
board of the CA-64 SR expander in version 1.6. When connecting the
readers to an older version of expander (1.5 or earlier), disable the
READER CONTROL option in the expander settings. The white cable of the
reader can be left unconnected, or connected to the common ground.
You can also connect this cable directly to the control panel so as to
monitor the reader presence. The cable is connected to the common
ground in the reader via a 2.2kOhm resistor. Program the zone to which
the cable is to be connected in the control panel as the "24H tamper" and
match the detector configuration accordingly.
6. TECHNICAL DATA
Data transmission standard...............................................................EM-MARIN
Supply voltage (±15%).............................................................................12V DC
Maximum current consumption...................................................................55mA
Head operating frequency........................................................................125kHz
Head operating temperature range.....................................................+5...+40°C
Head operating humidity range................................................................0...95%
Head dimensions.........................................................................127x35x21 mm
Weight...........................................................................................................72g