SATEL CZ-EMM 3
7. Connect the wires to the device screw terminals according to the table below.
Terminals
Wire Description Reader A Reader B
red power +GA +GB
green data SIGA / SIG1A SIGB / SIG1B
blue common ground COM COM
yellow sounder BPA BPB
pink LED green color LD1A LD1B
gray LED red color LD2A LD2B
brown blocking reader operation DISA DISB
white presence control TMPA TMPB
4. Using
Present the card to the reader so that the reader can read the card code. The card code will
be sent to the device to which the reader is connected. That device will decide what function
to run.
The device to which the reader is connected can distinguish between presenting the card
(one-time reading the card code) and holding the card (the card must be held in front of the
reader for about 3 seconds, and its code will be read repeatedly during that time). Another
function can be activated by presenting the card, and another by holding it.
The way the visual (LED) and audible (sounder) signaling works depends on the device to
which the reader is connected.
5. Specifications
Supply voltage .................................................................................................... 12 VDC ±15%
Maximum current consumption........................................................................................50 mA
Reader transmit frequency............................................................................................125 kHz
Operating temperature range...............................................................................-20°C...+55°C
Maximum humidity.......................................................................................................... 93±3%
Dimensions ....................................................................................................80 x 120 x 16 mm
Weight................................................................................................................................. 98 g