Satel ARF-100 User manual

®
RADIO SIGNAL LEVEL TESTER
ARF-100
arf100_en 08/08
The ARF-100 radio signal level tester is designed to work together with the ACU-100
wireless system controller. It is supported by the ACU-100 controller with firmware
version 1.05 or later. The tester enables checking the level of radio signal received
either by the controller from the tester, or by the tester from the controller. Thus it
facilitates selection of a suitable installation place for the ABAX system wireless
devices. The ARF-100 tester takes up one position on the list of wireless devices
supported by the controller. It is power supplied from a 9V 6LR61 alkaline battery.
1. Description of the tester
Fig. 1. View of the tester.

ARF-100 ABAX
2
Explanations for Fig. 1:
1 – tester ON/OFF button (designated ). Press and hold down the button for
approx. 3 seconds to switch the tester on/off. Switching the tester on is signaled
by 4 short and 1 long beeps. Switching the tester off is signaled by 3 short beeps.
2 – button (designated ) for selecting operation mode of LED indicator After
the tester is switched on, the LED indicator will show the level of signal received
by the tester from the controller. It is indicated by steady red light of the LED
(designated in Fig. 1 with number 5). Press the button to switch over the indicator
display mode to show information on the level of signal received by the controller
from the tester (the red LED will start blinking). Press the button again to toggle
between the LED indicator display modes.
3 – button (designated ) for selecting power supply mode simulated by the
tester of wireless device. The power supply mode has an impact on radio
signal level of the device. When switched on, the tester simulates operation of
the wireless device supplied from external power sources. By pressing the button
you will switch the tester over to the mode of simulating the battery-supplied
wireless device. This mode is indicated by red light of the LED designated in
Fig. 1 with number 4. If the signal level indicator LEDs are on, they will go off and
will only come on during the next response time, when they will show the
updated radio signal level. In this mode, light of the LEDs is dimmed. Press the
button again to switch the tester over to the mode of simulating the wireless
device supplied from the external power source. If you hold down the button for
more than 3 seconds, the tester will enter the dense polling mode and will stay
there as long as the button is depressed. In the dense polling mode, the
information on radio signal level will be refreshed every 2 seconds. At the
moment of updating the radio signal level data, the tester will generate 2 short
beeps.
4 – red LED indicating the type of power supply simulated by the tester of
wireless device:
- ON – wireless device supplied from battery (e.g. AMD-100, AMD-101 & APD-
100 detectors, ASP-205 siren),
- OFF – wireless devices supplied from external power sources (e.g. ACX-200
expander, ASP-105 siren, ASW-100 wireless control unit).
5 – red LED showing operation mode of the LED indicator:
- ON – the indicator shows the level of radio signal received by the tester from
the controller,
- blinking – the indicator shows the level of radio signal received by the
controller from the tester,
6 – radio signal level indicator. Consists of 7 LEDs (2 yellow and 5 green). The
LEDs are described by numbers which illustrate the percentage of signal level.
The indicator LEDs are blinking when the tester battery is low.

SATEL ARF-100 3
2. Description of use
In order to check the radio signal level and find the optimum installation position for
the wireless device by means of the tester, follow the procedure below:
•Install battery in the tester.
•Add the tester to the wireless system (see the ACU-100 controller user manual).
Each ARF-100 tester has the serial number 0000500.
•Using the designated button, select the power supply mode for the wireless
device to be installed and simulated by the tester.
•Start the test mode in the controller. During response time, the level of radio signal
received by the tester from the controller will be displayed on the LED indicator.
Press the designated button to see the level of signal received by controller
from the tester. The signal level is always refreshed during the response time
(which is signaled by 1 short beep). If a higher update frequency is required,
activate the dense polling mode by means of the button. The signal level
displayed on the LEDs will be refreshed every 2 seconds. Information update will
be signaled by 2 short beeps.
•Find the optimum location to install the new wireless device.
•Having completed the test, switch off the tester and remove it from the ABAX
wireless system.
Note:
•If not used, the tester will switch off automatically after 10 minutes.
•Only one tester can work in the wireless system.
3. Technical data
Working frequency band.............................................................868.0MHz ÷ 868.6MHz
Power supply..........................................................................alkaline battery 9V 6LR61
Working temperature range..........................................................................0°C...+55°C
Dimensions.............................................................................................. 70x196x32mm
Weight......................................................................................................................137g

ARF-100 ABAX
4
DECLARATION OF CONFORMITY
Product:
ARF-100 – radio signal level tester, ABAX system
Manufacturer: SATEL sp. z o.o.
ul. Schuberta 79
80-172 Gdańsk, POLAND
tel. (+48 58) 320-94-00
fax. (+48 58) 320-94-01
Product description:The radio signal level tester is designed to work together with the ABAX
wireless system controller within the 868.0MHz – 868.6MHz frequency band, supplied 9V 6LR61
alkaline battery. The device is intended to be used in burglary/panic alarm systems.
The product is in conformity with the following EU Directives:
R&TTE 1999/5/EC
The product meets the requirements of harmonized standards:
R&TTE: ETSI EN 300 220-1: v.1.3.1; ETSI EN 300 220-3: v.1.1.1;
EMC: ETSI EN 301 489-1 V1.6.1; ETSI EN 301 489-3 V1.4.1
Safety: EN60950
Notified entity participating in the conformity assessment :
Identification No.: 1471
Gdańsk, Poland 2007-01-11 Head of Test Laboratory:
MichałKonarski
The latest EC declaration of conformity and product approval certificates are available for
downloading on website www.satel.pl
SATEL sp. z o.o.
ul. Schuberta 79
80-172 Gdańsk
POLAND
tel. + 48 58 320 94 00
www.satel.pl
Table of contents
Other Satel Test Equipment manuals
Popular Test Equipment manuals by other brands

NARIKA
NARIKA A05-7856-W0 instruction manual

IDEAL
IDEAL Vol-Con 61-076 instruction sheet

GW Instek
GW Instek PEL-3000AH Series quick start guide

BACtrack
BACtrack Mobile Breathalyzer Getting started

Schumacher Electric
Schumacher Electric BT-175 owner's manual

Rigel Medical
Rigel Medical Rigel 288+ quick start guide

Keysight Technologies
Keysight Technologies U1452A quick start guide

trendmedic
trendmedic TM-8500 Premium Operational manual

Cirris
Cirris Touch 1 Getting started guide

ICS Schneider Messtechnik
ICS Schneider Messtechnik PPS 1210 Operating instruction

C-Tech
C-Tech Bohme STM-B product manual

Desco
Desco EMIT 500524 operating instructions