UVinex™system not
oprating.
a) Connect UV plug to a working
outlet.
b) Reset GFCI. If this occurs
often consult an electrician.
c) Replace fuse or reset circuit
breaker. If this occurs often
consult an electrician.
d) Replace bulb.
e) Replace transformer.
a) UV is not plugged in.
b) GFCI switch (ground fault
circuit interrupt) has
tripped.
c) Domestic fuse has blown.
d) UVinex™ bulb needs replacing.
e) UVinex™ transformer has failed.
Faults Possible Causes Remedies
Trouble Shooting
Transformer Light RED a) Bulb not connected to transformer
b) UVinex™ bulb needs replacing.
c) Transformer Needs to be reset
a) Unplug from electrical circuit.
Unscrew junction box and reconnect
bulb into transfromer, reassemble
and restart
b) Replace Bulb
c) Unplug transformer from circuit
Bulb Not Lit a) Coating is Cracked or broken
b) UVinex™ bulb needs replacing.
c) Transformer Needs to be reset
a) Check coating for signs of
breakage or cracks. Replace bulb.
b) Replace Bulb
c) Unplug transformer from circuit
allow 2 minutes and restart
Faults Possible Cause Remedies
Uvinex System trips GFCI a) Bulb coating is Cracked or broken
b)Too much output for the electrical
outlet
a) Replace Bulb
b) Unplug any other items plugged
into same circut. Have an electrician
check circuit.
Water not Clearing a)Not enought UV output .
b)Too much Clacuim Buildup
c) Not enough Bio-Mechanical
Filtration
d) Needs Additional time for extreme
buildup
a) Check UV output ratio to Pond
Gallons and Pump our put (GPH) .
Additional wattage needed.
b) Wipe UV coating with clean cloth
to remove build up.
c) Check your pond gallons and
waste accumilation to the amount
of filtration needed. Add additional
filtration.
d) If starting UV system under
extreme algea buildup - allow
additional time for clarification.
Standard 3-4 weeks.