Savio UVinex SUV050A User manual

Savio UVinex™systems provide unparalleled water clarity for your
pond. UVinex™offers a safe, chemical free solution for eliminating
green water. By adding a UVinex™system you’ll also enhance the
filtration capabilities of your Savio Skimmerfilter. ®
System
uv clarier
For use with the S
av
i
o
Standard Skimmerfilters Only
OPERATING MANUAL
DO NOT REMOVE PLASTIC
PROTECTIVE COATING FROM BULB.
Read entire instructions prior to assembly and operation.
SUV050A
SUV026A
SUV018A

Uvinex Components
The Uvinex System Should come fully Assembled. Do not disassemble. Examine all parts while
unpacking. Carefully inspect Uvinex bulb for damage incurred during shipping. If unit appears
damaged, contact the dealer you purchased it from for a replacement. Do not use if damage if
evident.
Junction Kit
RU118
Transformer
RU116 - 18/26 watt
RU117 - 50 watt
Coated Bulb
RU1805 - 18 watt
RU2605 - 16 watt
RU5005 - 50 watt

Junction Screws
RU119
Cap Seal
RU125
Cord Seal
RU124
Metal ORing
RU127
Junction Cap Bottom
RU121
Junction Cap Top
RU120
Screw Ring Male
RU122
Grommet
RU126
Rubber ORing
RU128
Screw Ring Female
RU123
Replacement Bulb
RU1805
RU2605
RU5005

If installing a single UV, you may use either the left or right
skimmer UV mount on the standard skimmerlter. If using the compact
skimmer lter only use the center UV mount.
1
If using a single UV, a bafe block can be used to prevent water movement
through unused UV chamber. This provides improved UV exposure.
2
Place UV into skimmer by inserting the bulb into the UV mount.
3
Use a Phillips screwdriver and the scews provided to secure the unit. Extra
screws are provided.
4
To start system: Plug UV into GFCI protected outlet. UV must be used in
conjunction with a ground fault current interrupter socket (GFCI).
(If you do not have a GFCI, contact a licensed electrician before using the
UV.)
5
Uvinex Installation

For green water clarication, the pump needs to ow the total volume of pond water past
the UV no less than every two hours. In full size Skimmerlters®two UVs may be used for
increased clarication.
Prior to performing any maintenance always unplug the UVinex™ system. Use caution when
removing or replacing bulbs.
Every Three Months:
Coated bulb should be wiped with a clean cloth & rinsed with clean water.
Annually or As Needed:
Replace UVinex™ bulb every 12 months for optimal water clarity.
Allowing the UVinex™ system to freeze can result in breakage to the bulb.
Winterize pond equipment before ice develops on the pond. Keep equipment winterized until
spring when the water temperature rises to 40°F or higher consistently.
To winterize UV:
1) Disconnect electrical connections.
2) Remove the UV from the Skimmerlter®.
3) Dry UV unit thoroughly and clean bulb.
4) Store indoors in a safe place.
Recommended Flow Rates
18 Watt
UVinex™
Minumin 33% of total volume of pond water per hour (gph)
Maximum 2000 Gallons per Hour (GPH)
26 Watt
UVinex™
Minumin 33% of total volume of pond water per hour (gph)
Maximum 2500 Gallons per Hour (GPH)
50 Watt
UVinex™
Minumin 33% of total volume of pond water per hour (gph)
Maximum 4750 Gallons per Hour (GPH)
Maintenance
Winterizing

Important Safety Instructions
Water and electricity can be deadly when combined. This unit can pose signicant risk of bodily harm if
used incorrectly. Please read the following instructions carefully.
WARNING - ELECTRICAL SHOCK HAZARD.
• Never immerse the ballast/transformer unit in water.
• Never immerse the entire UVinex™ system in water.
• UV must be used in conjunction with a ground fault current interrupter socket (GFCI).
(If you do not have a GFCI, contact a licensed electrician before using the UV.)
• If the UV’s internal components get wet, unplug the unit immediately.
• If bulb shows signs of leakage unplug the unit immediately.
• Do not operate UV with a damaged cord or plug, if it has been dropped, or is malfunctioning.
• Do not attempt repairs on a damaged transformer unit.
• Always unplug unit when not in use and prior to servicing it.
• Never remove the UV from the Skimmerlter® by pulling on the cord.
• Always pull the plug from the outlet, never pull the cord.
UV Light Warning
• Do not operate UV unless it is fully installed in the Sav
i
o Skimmerlter® .
• UV lamps emit radiation that is harmful to eyes and skin. Do not look directly
at UV while in operation.
• UV lamps are made from glass and must always be
handled with caution.
• Closely supervise children around all pond equipment.
• The Savio UVinex™ system is for use solely in Savio Skimmerlters®.
Do not use in any other environment.

UVinex™system not
oprating.
a) Connect UV plug to a working
outlet.
b) Reset GFCI. If this occurs
often consult an electrician.
c) Replace fuse or reset circuit
breaker. If this occurs often
consult an electrician.
d) Replace bulb.
e) Replace transformer.
a) UV is not plugged in.
b) GFCI switch (ground fault
circuit interrupt) has
tripped.
c) Domestic fuse has blown.
d) UVinex™ bulb needs replacing.
e) UVinex™ transformer has failed.
Faults Possible Causes Remedies
Trouble Shooting
Transformer Light RED a) Bulb not connected to transformer
b) UVinex™ bulb needs replacing.
c) Transformer Needs to be reset
a) Unplug from electrical circuit.
Unscrew junction box and reconnect
bulb into transfromer, reassemble
and restart
b) Replace Bulb
c) Unplug transformer from circuit
Bulb Not Lit a) Coating is Cracked or broken
b) UVinex™ bulb needs replacing.
c) Transformer Needs to be reset
a) Check coating for signs of
breakage or cracks. Replace bulb.
b) Replace Bulb
c) Unplug transformer from circuit
allow 2 minutes and restart
Faults Possible Cause Remedies
Uvinex System trips GFCI a) Bulb coating is Cracked or broken
b)Too much output for the electrical
outlet
a) Replace Bulb
b) Unplug any other items plugged
into same circut. Have an electrician
check circuit.
Water not Clearing a)Not enought UV output .
b)Too much Clacuim Buildup
c) Not enough Bio-Mechanical
Filtration
d) Needs Additional time for extreme
buildup
a) Check UV output ratio to Pond
Gallons and Pump our put (GPH) .
Additional wattage needed.
b) Wipe UV coating with clean cloth
to remove build up.
c) Check your pond gallons and
waste accumilation to the amount
of filtration needed. Add additional
filtration.
d) If starting UV system under
extreme algea buildup - allow
additional time for clarification.
Standard 3-4 weeks.

To activate your visit the Savio website (www.savioeng.com/waranty).
Savio Engineering provides a manufacturer’s limited warranty of 1 year from original
purchase date. Warranty does not cover consumables or wear items such as bulbs
or o-rings. Warranty is non-transferable. Within the warranty period SAViO will repair
materials with manufacturing deficiencies at their discretion. This warranty does not
cover any faults caused by improper use, installation and handling of the device or as a
result of wear and tear. Savio Engineering, does not assume liability for consequential
damage caused by the failure of the Savio UVinex™ system. Removal of cord or ground
pin voids warranty.
Warranty is void if the product is not used in accordance with instructions. For warranty
claims, please contact your dealer or submit a warranty claim on www.savioeng.com/
warranty.