Care and Safety
Microwave Movement Sensor
The light will not come on
The lamp is always on
The lamp will not work
despite movement
Check detection area setting
The lamp is on without any
identifiable movement
Incorrect light-control setting selected
Continuous movement in the detection zone
The sensor is not mounted for reliably detecting movement
Movement occurred, but not identified by the
sensor (Movement behind wall, movement of
small object in immediate lamp vicinity etc.)
Rapid movements are being suppressed to minimize
malfunctioning or the detection radius is too small.
Faulty lamp
No power supply
Adjust daylight threshold setting
Replace lamp
Check power to sensor
Check detection area setting
Securely mount enclosure
1. Reduce sensitivity.
2. Check the movement behind walls to avoid
facilities such as water pipe, fan, which
may mis-trigger the sensor.
Trouble shooting:
Malfunction Cause Remedy Cause Remedy
This product is fitted with a microwave movement sensor. Please see below detailed operating instructions.
Settings:
123
100%
75%
50%
25%
10%
1. Sensitivity
Sensitivity can be adjusted by selecting the
combination on the DIP switches for different
applications.
I –100%
II – 75%
III – 50%
IV – 25%
2. Hold-time
Hold-time refers to the time period that the light
remains 100% on if no more movement is
detected.
I – 5s
II – 30s
III – 90s
IV – 3min
3. Daylight sensor
Different daylight threshold can be preset on DIP
switches. Light will always turn on upon movement if
daylight sensor is disabled.
789
2Lux
10Lux
25Lux
50Lux
Disable*
456
5s
30s
90s
3min
20min
30min
I – 2Lux
II – 10Lux
III – 25Lux
IV – 50Lux
V – Disable
*Disable means the daylight sensor does not work. The sensor will turn
on light once motion is detected regardless of ambient light level.
V – 10% V – 20min
VI – 30min
*50%, 75%, 100% detection sensitivity is workable when installed at 6m mounting height. Only 10%, 25%
sensitivity is not able to detect motion signal.
Technical Specifications:
Operating voltage 220 ~ 240V AC 50/60Hz
Rated load 400W (Capacitive load) 800W (Resistive load)
Stand-by power ≤0.5W
Sensitivity
Hold-time 5s / 30s / 90s / 3min / 20min / 30min
Daylight sensor 2Lux / 10Lux / 25Lux / 50Lux / Disable
Microwave frequency 5.8 GHz ±75MHz
Transmitting power 1mW Max.
12-15m
3- 6m (radius )
Detection angle 360
0
(Ceiling) / 120
0
(Wall)
Working temperature -20
0
C ~ 60
0
C
100% / 75% / 50% / 25% / 10%
Ceiling mounted
height: 3m
Ceiling mounted
height: 3m
Wall mounted
height: 1.5-2m
Ceiling mounted
height: 6m
Wall mounted
height: 2m
100% / 75% / 50%
100% / 75% / 50% / 25% / 10%
*
Detection range

Warning
Please read these instructions carefully before commencing any work.
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building
Regulations.
Check the pack and make sure you have all the parts listed.
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will
reach the distances between each light fitting.
Avoid locating any cables in positions that would cause a hazard. Position
cables and junction boxes (not supplied) away from areas where they may
be at risk from being cut, trapped or damaged.
Installation
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.
Note that the switch is turned off before installation.
The ceiling surface must be flat and smooth to ensure a good fit.
Ensure that the screws and cable entry points are sealed to maintain
the IP rating of the product.
Technical data
240 V~, 50 Hz
Supply
Voltage:
Bulb
Type: 9/14/18W LED module (SMD) CCT, 3000/4000/6000K
The light source of this luminaire is not replaceable; when the light source reaches its end of life the
whole luminaire shall be replaced.
Conformity with all relevant EC Directive requirements.
The power supply is Double Insulated and does not require
connection to an Earth circuit.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.
Check with your Local Authority or local store for recycling advice.
This product is rated at IP65
IP
65
Wiring
This light fitting is double insulated and does
not require connection to an earth circuit.
To prevent electrocution switch off at the mains supply before installing or
maintaining this fitting. Ensure other persons cannot restore the electrical
supply without your knowledge.
If you are in any doubt, please consult a qualified electrician.
This light fitting should be connected to a circuit with a 30mA RCD fitted.
If replacing an existing fitting, make a careful note of the connections.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or retailer
for recycling advice.
The mains supply cable must have a minimum cross section area of 1.0mm2.
Cables must be protected using suitable conduit or plastic trunking.
The products can be wall or ceiling mounted. If wall mounting ensure that
the power supply is at the bottom.
Individual casings
The following individual casings are available for purchase separately.
95545 : Chrome plain
95546 : White eyelid
95547 : White grill
95548 : Black plain
95549 : Black eyelid
95550 : Black grill
95551 : Anthracite grey plain
95552 : Anthracite grey eyelid
95553 : Anthracite grey grill
• Twist and remove the lamp cover from the product, keep safe for refitting later.
• Turn the clip to loose the LED tray in the rear casing.
• Using the rear casing as a template mark the position to drill out the fixing holes.
Take care to avoid damaging any concealed wiring and pipes.
• Fix the rear casing into the position using the installation plugs and screws.
• Pull the cable through the cable entry hole and seal to maintain the IP rating
and wire as detailed Wiring Diagram.
Ø6mm
1 2 3
4 5 6
See Wiring
diagram
• Replace fuse or circuit breaker and switch on. Your light is now ready for use.
• Refit the LED tray back into the rear casing and lock the clip.
• Twist the lamp cover back onto the product and lock in place.
Having correctly identified the wiring from your existing light fitting, pull the mains wire through the hole and connect to the
quick fit connection block in the following way. No tools are necessary.
You have correctly identified the wires.
The connections are tight.
No loose strands have been left out of the connection block.
Check that...
PUSH DOWN
INSET CABLE
LIGHT FITTING
SUPPLY
NEUTRAL
SWITCHED LIVE
BLUE (N)
BROWN (L)
L
N
This product is not suitable for dimming.
This product is rated at IK10.
IK10
The wattage is changeable between 9/14/18W using
the wattage switch on the drive before installation.
18W 14W 9W
The colour is changeable between 3000/4000/6000K
using the CCT switch on the drive before installation.
6000K 4000K 3000K
Other Saxby Lighting Accessories manuals
Popular Accessories manuals by other brands

PCB Piezotronics
PCB Piezotronics 356A66 Installation and operating manual

Exit
Exit Silhouette 12.93.06 user manual

Atek
Atek AWP 110 Series user manual

Jumpking
Jumpking A4 user manual

Trust
Trust SMART Home START-LINE ACDB-6600AC Multi Language User Manual

Lippert Components
Lippert Components Solera Installation and owner's manual

Honeywell
Honeywell 5 series Installation and operation guide

Maxim Integrated
Maxim Integrated MAX32664A quick start guide

SOL paragliders
SOL paragliders Calliplox Reverse manual

Captron Electronic
Captron Electronic CHT4-2 Original operating instructions

Vinotemp
Vinotemp WINE-MATE WM-2500SSIWC Operation Care Installation Manual

METER
METER ATMOS 14 quick start