Thankyouforpurchasingthislightfitting.Pleasereadtheinstructionscarefullybeforeusetoensuresafeand
satisfactoryoperationofthisproduct.Pleaseretaintheseinstructionsforfuturereference.
Warning
The power supply is Double Insulated and does not
require connection to an Earth circuit.
The LED units are Safety Extra Low Voltage and
must not be earthed.
Please read these instructions carefully before
commencinganywork.
Thisunitmustbefittedbyacompetentandqualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
ThissystemoperatesatSafetyExtraLowVoltage
(12V),viaatransformer.Neverconnectthelight
fittings directly to the mains without using a
transformer.
Ensurethatthesuppliedtransformerisused.
Themainsplugmustbesituatedindoors(e.g.house,
garage,shed)inordertoprotectitfromtheelements.
Donotexceedthetransformerload.Transformersmay
requireaminimumloadtooperate.
Always disconnect the transformer from the mains
when installing or maintaining this system.
Thissystemcontainsnon-replaceablepartsand
cannotbeserviced.Ifdamageoccursthepartshould
bescrapped.
Thisproductcannotbedimmed.
ThisproductisratedatIP44.
Wasteelectricalproductsshouldnotbedisposedof
with household waste. Please recycle where facilities
exist.Checkwithyourlocalauthorityorretailerfor
recyclingadvice.
Specification
TheKitcontains:
• 1x12VIndoorplug-intransformerwith5metreextensionlead,
• 10xIP44LEDlightfittingseachwith1metreofcableattached,
Layout
• Planthedesiredlayoutofthesefittingscarefully,
ensuring the cables will reach the distances between
the indoor transformer and each light fitting.
• Avoidlocatinganycablesinpositionsthatwould
causeatriphazard.Positioncablesawayfromareas
wheretheymaybeatriskfrombeingcut,trappedor
damaged.
• Maximumdistancebetweenheadsis800mm.
• Ensuretheconnectorsareaccessibleforfuture
maintenance.
• Theplug-intransformerhasnospecialprotection
against moisture and must be situated indoors.
• ThelightunitsareratedatIP44.Avoidpositioning
headunitsandconectorsinverywetareas.
• Positiontheplug-intransformernexttotheindoor
mainsoutletsocketthatthesystemwillconnectto.
Donotplug-inatthisstage.
• Afterdecidingthelayoutofthelightfittings,ensure
the cables are long enough to connect to the desired
positions.
• Drillthemountingholesforthelightunitstakingcare
nottodamageanypipesormainscablesbeneath
themountingsurface.Theserequirea22mm
clearance hole.
• Feedtheplugandcablesofeachlightunitthrough
themountingholesandpushunitintotheholeto
secure.
• ConnecteachLEDlighttothenextLEDlight
ensuring the arrows on connectors are facing each
otherandallplugsarefullyfittedintothesockets.
See COnnectors Drawing below.
• Connecttheextensioncabletothetransformer.
• Plugthetransformerintothemainssocketand
switch on.
Installation
End cap
30mm diameter LED
22mm diameter
mounting hole
(minimum30mmdepth)
• Werecommendcleaningwithasoftdrycloth.
• Donotusesolventsorabrasivecleanersasthese
could damage the finish.
• Toprolongthelifeandconditionoftheproduct,itis
recommendedthatperiodicallyitiscleanedusinga
softclothfollowedbytheapplicationofalightcoating
of oil, such as WD40.
• Donotcleantheunitswithapressurewasher.
Connectors
Wasteelectricalproductsshouldnotbedisposedofwithhouseholdwaste.Pleaserecyclewherefacilities
exist.CheckwithyourLocalAuthorityorretailerforrecyclingadvice.