Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
Technical data
Please read these instructions carefully before
commencing any work.
This light fitting should be connected to a fused
circuit.
This unit must be fitted by a competent and
qualified electrician.
Check the pack and make sure you have all of the
parts listed.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting.
Ensure other persons cannot restore the electrical
supply without your knowledge.
Install in accordance with IEE Wiring regulations
and current Building Regulations.
Supply
Voltage: 240V~, 50 Hz 16 Amp max Power load : Max. 3840W
Conformity with all relevant EC Directive requirements.
Waste electrical products should not be disposed of with household waste.
Class I product, must be connected to earth.
Please recycle where facilities exist.Check with your Local Authority or
local store for recycling advice.
Track accessory
Installation
Cutting track
IP20
Always switch off mains supply before fitting or
servicing.
All pre - cut mains tracks, is supplied complete
with ready inserted dead end insulation caps
and live end.
It is recommended that luminaires are installed by
a qualified electrician who should ensure that the
installation complies with the current IEE wiring
regulations BS7671:2008.
Any broken or damaged parts should be replaced
as soon as possible.
Saxby will not accept responsibility for any claims
arising from a sub-standard installation.
If replacing an existing fitting, make a careful note
of the connections.
Layout
This track system can be extended to a variety of different configurations using accessories such as left
When reducing the lenght of track i.e. cutting down. It is recommended that a piece of masking tape be wrapped
around the intended cutting area, this will ensure the powder coated or plated finish does not lift and chip.
It is recommended for a good electrical connection the installer should always mark out and cut track accurately
using an engineers square prior to cutting. Ensure the copper conductors are pushed fully to one end of the track
prior to cutting. the conductors should be towards the live end termination point
bends, right bends, T jucntions, X junctions and flexible joints.
TJ unction
X J unction
Dead End
Bend
108.0mm
35.0mm
35.5mm
79.5mm
294.0mm
35.0mm
35.0mm
108.0mm
108.0mm
35.0mm
16.5mm
183.0mm
183.0mm
35.0mm
35.0mm
108.0mm
183.0mm
40.0mm 40.0mm
43.0mm
35.0mm
182.0mm
78660
78661
78662
78657
78658
78659
78654
78655
78656
720
865
860 995 860
865 110
110
110
FIG-1 FIG-2 FIG-3
FIG-4 FIG-5 FIG-6
The indentation line on the
live end connector must be
on the same side with the
protruding edge on the track
L
220V-240V 16A
N
E
The raised marks on the
side of the track adaptor
must be on the same side
with the flat side of the track