SBC PCD7.L630 User manual

Document 26-859; Edition ENG07 │ 2015-06-04
Manual
Room controller units PCD7.L6xx,
Extension modules, Accessories

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
Content
0-1
0
0 Content
0 Content
0.1 Document History ............................................................................................... 0-2
0.2 About this manual .............................................................................................. 0-2
0.3 Brands and trademarks ..................................................................................... 0-2
1 Assembly instructions
2 Analogue room control units
2.1 Techn.specicationsofanalogueroomcontrolunitsPCD7.L630-.L632......... 2-2
2.1.1 TechnicaldataforPCD7.L630........................................................................ 2-4
2.1.2 TechnicaldataforPCD7.L631....................................................................... 2-5
2.1.3 TechnicaldataforPCD7.L632........................................................................2-6
3 Digital room control units
3.1 TechnicalspecicationsofdigitalroomcontrolunitsPCD7.L640-.L644.......... 3-2
3.1.1 TechnicaldataforPCD7.L640........................................................................ 3-4
3.1.2 TechnicaldataforPCD7.L641........................................................................ 3-5
3.1.3 TechnicaldataforPCD7.L642........................................................................3-6
3.1.4 TechnicaldataforPCD7.L643........................................................................ 3-8
3.1.5 TechnicaldataforPCD7.L644........................................................................ 3-10
Operation / Menu structur ............................................................................... 3-12
3.1.6 TechnicaldataforPCD7.L660/PCD7.L661(versionsSV1.5andSV6.1)..... 3-13
3.1.7 TechnicaldataforPCD7.L662/PCD7.L663(versionSV2.8K)...................... 3-18
3.2 TechnicaldataforPCD7.L650........................................................................... 3-23
3.2.1 Light: 2lightgroupswithsensorcommands'on'and'off'
Shade: 2groupsup/downviaelectronicsensor............................. 3-25
3.2.2 Light: 1lightgroupsensoron,automaticoffaftertimedelay
Shade: 2groupsshadesup/down..................................................3-26
3.2.3 Light: 1lightgroupsensoron,offvianetworkcommand
Shade: 2groupsshadesup/down..................................................3-27
3.2.4 Light: 2groupsviaswitch
Shade: 2groupsviachangeovercontactsup/down....................... 3-28
4 Cables for room controllers and room control units
A Appendix
A.1 Icons ...................................................................................................................A-1
A.2 Order codes .......................................................................................................A-2
A.3 Contact..............................................................................................................A-4

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
Content
0-2
0
0.1 Document History
Date Version Changes Remarks
2008-09-30 EN01 - TranslationofGermanversion
2010-05-03 EN02 PCD7.L630 Connectionwithspringterminalblock,
notwithRJ-11
2010-09-15 EN03 PCD7.L67x Newtypesofconnectingcablesintegrated
2013-02-15 EN04 PCD7.L670
PCD7.L672 Newnumberingofthestrands
2013-09-27 EN05 Newlogoandnewcompanyname
2013-11-13 EN06 A.2 PCD7.L666don’tworkwithIR
2015-06-04 ENG07 Ch01
A.3
Newchapter:Assemblyinstructions
Newphonenumbers
0.2 About this manual
Seethesectionintheappendixinrelationtosomeoftheterms,abbreviationsand
thereferencesusedinthismanual.
0.3 Brands and trademarks
SaiaPCD®andSaiaPG5®
areregisteredtrademarksofSaia-BurgessControlsAG.
Technicalmodicationsarebasedonthecurrentstate-of-the-arttechnology.
Saia-BurgessControlsAG,2015.©Allrightsreserved.
PublishedinSwitzerland

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
Assembly instructions
1-1
1
1.5 m
Avoid direct exposure to sunlight or
light from powerful lamps.
Donotinstallnexttoheatsourcessuch
asheaters,refrigerators,lampsetc.
Donotinstallnexttowindowsanddoors
becauseofdraughts.
1 Assembly instructions
■ Theroomcontrolunitsmustonlybeinstalledandconnectedbyanexpertin
accordancewiththewiringdiagram.Existingsafetystandardsmustalsobe
observed.
■ Theroomcontrolunitscanonlybeusedtoregulatethetemperatureindry,
closedrooms.Themaximumpermissiblerelativehumidityis90%,non-
condensing.
■ Precisetemperaturemeasurementissubjecttocertainrequirementsastothe
positioningofthetemperaturesensors.Thisappliesbothtotheroomcontrol
deviceitselfandtotheexternallyconnectedtemperaturesensor.
■ Thedevicecanbemounteddirectlyonthewallorush-mountedwithina
pattressbox.
Donotlocatedthecontroldevice/
compact room controller in the path
ofdraughtsfromclimatecontrolor
ventilationsystems.

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
Assembly instructions
1-2
1
Saia®DDC
Saia®
DDC
1
Assemblingthe
housingbase
2
Wiringtothedevice 3
Unlocking
Please ensure:
● thatallwiresarescreweddowntight
● thattheconnectingplugisproperlyengaged
● thattheventilationslotsareplacedaboveandbelow(positioning)
● thatthedeviceismountedhorizontally.
To prevent a premature oxidation and yellowness of the plastic enclosure of
the room control unit, the following installation conditions has to be prevent
(non-exhaustive list):
■ Exposuretointensivesunlightorintensivearticiallights(intensiveneontubes
lightinparticular)
■ Exposuretochemicalproductssuchas:intensive&frequentuseofcleaning
chemicalproducts(Bleach,…),disinfectantspraysetc.
■ Exposuretohighhumidityrates;saltedhumiditycouldincreasefurtherthe
oxidation
■ Exposuretohighratioofoxygen
■ Exposuretohighheat
4
Removethecase
Mounting Removal

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
Analogue room controller units
2-1
2
2 Analogue room control units
PCD7.L63x Generaltechnicalspecication
- - -
PCD7.L630 Room temperature sensor
PCD7.L631 Roomtemperaturesensorwithsetpointsetting
PCD7.L632 Roomtemperaturesensorwithsetpointsetting,
presencesensorandLED

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
Analogue room controller units
2-2
Technicalspecications
2
2.1 Techn.specicationsofanalogueroomcontrolunitsPCD7.L630-.L632
RJ 11
PCD7.L671
potentiometer
consigne
LED
comfort
cateur de temperature
button d'occupation
10k, linear
bleu
jaune 5V
1k5
P1
GND
S
verte
rouge
noir
blanc
GND
Pin allocation PCD7.L630 - .L632
Signal Terminal Description
Temperature sensor S,GND TemperaturesensorNTC10kΩ,
measurementrange0…40°C.
Presencesensor S,GND Floatingsensorusingthetemperaturesensor.
Setpointsetting 5V,P1,GND Potentiometer(10kΩ,linear)forsettingacong-
urablesetpointdisplacement.Seedescriptionof
CongFBoxorregisters(reg.104)
LED LED,GND LEDtodisplayComfortmode.Comfortmode=5V,
otherwise0V.(5V,2mAmax.)
PCD7.L671 connecting cable - colour table
Colour Terminal Description
White S Temperature/presence sensor
Black GND Ground
Red P1 Potentiometercentretap
Green Not used
Yellow 5V Potentiometerpowersupply
Blue LED LEDwith1.5kΩseriesresistance.(max.2mA)
Note
AllinformationpointscanbereadbytheSBCS-BusviaaRoomFBoxorviaregis-
tersindependentlyoftheapplication.
Theuseofananalogueroomcontrolunitmustbeindicatedintheroomcontroller
conguration.SeedescriptionofCongFBoxorregisters.

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
Analogue room controller units
2-3
Technicalspecications
2

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
Analogue room controller units
2-4
Technical data
2
2.1.1 TechnicaldataforPCD7.L630
GND
S
Temperature sensor
black
white
Room temperature sensor
Pin allocation for PCD7.L630
Signal Terminal Description
Temperature sensor S,GND TemperaturesensorNTC10kΩ,
measurementrange0…40°C.
Pin allocation for connecting cable PCD7.L671
Colour Terminal Description
White S Temperature/presence sensor
Black GND Groundforthetemperaturesensor
Note
All informationpointscanbereadbytheSBCS-BusviaaRoomFBoxorviaregis-
tersindependentlyoftheapplication.
Theuseofananalogueroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
Analogue room controller units
2-5
Technical data
2
2.1.2 TechnicaldataforPCD7.L631
RJ 11
PCD7.L671
potentiometer
Consigne
capteur de
température
10k, linéare
bleu
jaune 5V
P1
GND
S
verte
rouge
noir
blanc
GND
Roomcontrolunitwithtemperaturesensorandsetpointsetting.
Pin allocation for PCD7.L631
Signal Terminal Description
Temperature sensor S,GND TemperaturesensorNTC10kΩ,
measurementrange0…40°C.
Setpointsetting 5V,P1,GND Potentiometertosetacongurablesetpointdis-
placement.SeedescriptionofCongFBoxorregis-
ters(reg.104)
PCD7.L671 connecting cable - colour table
Colour Terminal Description
White S Temperature sensor
Black GND Ground
Red P1 Setpointpotentiometer
Green Not used
Yellow 5V Setpointpotentiometerpowersupply
Blue LED LEDwith1.5kΩseriesresistance.(max.2mA)
Note
All informationpointscanbereadbytheSBCS-BusviaaRoomFBoxorviaregis-
tersindependentlyoftheapplication.
Theuseofananalogueroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
Analogue room controller units
2-6
Technical data
2
2.1.3 TechnicaldataforPCD7.L632
RJ 11
PCD7.L671
potentiometer
consigne
LED
comfort
cateur de temperature
button d'occupation
10k, linear
bleu
jaune 5V
1k5
P1
GND
S
verte
rouge
noir
blanc
GND
Roomcontrolunitwithtemperaturesensor,setpointsettingandilluminatedpresence
sensor.WhenthecontrollerisworkinginComfortmode,thesemi-transparentsensor
lightsup.
Pin allocation for PCD7.L632
Signal Terminal Description
Temperature sensor S,GND TemperaturesensorNTC10kΩ,
measurementrange0…40°C.
Setpointsetting 5V,P1,GND Potentiometertosetacongurablesetpointdis-
placement.SeedescriptionofCongFBoxorregis-
ters(reg.104)
LED LED,GND Thepresencesensorlightsupwhenthecontrolleris
runninginComfortmode.
PCD7.L671 connecting cable - colour table
Colour Terminal Description
White S Temperature sensor
Black GND Ground
Red P1 Setpointpotentiometer
Green Not used
Yellow 5V Setpointpotentiometerpowersupply
Blue LED Presencesensorillumination
White STemperature/presence sensor
Note
All informationpointscanbereadbytheSBCS-BusviaaRoomFBoxorviaregis-
tersindependentlyoftheapplication.
Theuseofananalogueroomcontrolunitmustbeindicatedintheconguration.See
descriptionofCongFBoxorregisters.

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
3
Digital room controller units
3-1
3 Digital room control units
PCD7.L64x Generaltechnicalspecication
- - -
PCD7.L640 Roomtemperaturesensorwithsetpointsetting
PCD7.L641 Roomtemperaturesensorwithsetpointsetting,
presencesensorandLED
PCD7.L642 Roomtemperaturesensorwithsetpointsetting,
presencesensor,LEDandfancontrol
PCD7.L643 Roomtemperaturesensorwithfunctionkeysand
LCDdisplayforHeaVACfunctions.
PCD7.L644 Roomtemperaturesensorwithfunctionkeysand
LCDdisplayforHeaVACfunctions,andlightand
shadefunctions
- - -
PCD7.L660 Mobileroomcontrolunitwithinfraredinterface,
temperaturesensor,functionkeysanddisplay
PCD7.L661 infraredreceiver
PCD7.L662 Mobileroomcontrolunitwithinfraredinterface,
temperaturesensor,functionkeysanddisplay
PCD7.L663 wirelessreceiver
- - -
PCD7.L650 Interfacemoduletoconnectupto8oatingcontactsin
combinationwitharoomcontroller

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
3
Digital room controller units
3-2
3.1 TechnicalspecicationsofdigitalroomcontrolunitsPCD7.L640-.L644
RJ 9
Controller
PCD7.L670-xx
PCD7.L642
yellow
green
red
black
LED
comfort mode
Setpoint
potentiometer
temp.-sensor
Occupancy button
Occupancy button
RJ 9
Controller
PCD7.L670-xx
Set
Display
PCD7.L643
yellow
green
red
black
temp.-sensor
Occupancy button
HEVAC function
Pin allocation for PCD7.L640 - .L644
Interface Terminal Description
Serialbus RC Theconnectiontotheroomcontrollerisdonewiththe
cablePCD7.L670-xxdirectlyonthecontrollerortheuse
ofexpansionmodulesforlightingandshadingonthelast
module.
Thepowercable,PCD7.L670-xx,isprefabricatedonboth
sidesandhasalengthofeither10,30or50m.
Themaximumlengthbetweentheroomcontrollerandthe
controlroomcontrolunitmustnotexceed50meters.

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
3
Digital room controller units
3-3
Functions for PCD7.L640 - .L644
Function Description
Sensor Roomtemperaturesensor.Measurementrange0…40°C.
Setpointsetting Tosetacongurablesetpointdisplacement.Depend-
ingontheroomcontrolunit,thesettingisenteredwitha
potentiometerorviatheintegrateddisplaywithHeaVAC
function.Thebasesetpointheldintheroomcontrollercan
beincreasedordecreasedinupto6steps.Thestepsize
isstoredintheroomcontrollerconguration.Seedescrip-
tionofCongFBoxorregisters(reg.104).
WhenthePlus,SetandMinuskeysarepressedtogether,
thecurrentsetpointisdisplayedforapprox.20seconds.
Presencesensor Thepresencesensorcanbeusedtochangetheoperat-
ingmodemanuallytoComfortorStandby/unused.Onthe
L640-L642controlunits,thepresencesensorlightsupin
Comfortmode.Ontheunitswithdisplays,theoperating
modeisshownonthedisplay.Thepersoniconoutside
thelittlehouseindicatesnon-use;ifthisiconisashing,
thecontrollerisinStandbymode.InComfortmode,the
personiconmovesintothehouse.
Note
AllanalogueinputsontheroomcontrollercanbereadbytheS-BusviaaRoom
FBoxorviaregistersindependentlyoftheapplication.
Theuseofadigitalroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
3
Digital room controller units
3-4
3.1.1 TechnicaldataforPCD7.L640
RJ 9
Controller
PCD7.L670-xx
PCD7.L640
yellow
green
red
black
Setpoint
potentiometer
temp.-sensor
Roomcontrolunitwithtemperaturesensorandsetpointsetting.
Pinallocation
Interface Terminal Description
Serialbus RC Theconnectiontotheroomcontrollerismadewiththe
PCD7.L670-xxdirectlytothecontroller,orwhereexten-
sionmodulesareusedforlightandshade,tothelast
module.ThePCD7.L670-xxconnectingcableisprecon-
guredatbothendsandiseither10,30or50mlong.
Themaximumlengthbetweentheroomcontrollerandthe
roomcontrolunitmustnotexceed50m.
Functions
Function Description
Sensor Roomtemperaturesensor.Measurementrange0…40°C.
Setpointsetting Tosetacongurablesetpointdisplacement.Thesetting
isenteredviaapotentiometer.Therangeisconvertedinto
+/-6stepsandpassedtotheroomcontroller.Thebase
set point held in the room controller can be increased or
decreasedinsteps.Thestepsizeisstoredintheroom
controllerconguration.SeedescriptionofCongFBoxor
registers(reg.104).WhenthePlus,SetandMinuskeys
arepressedtogether,thecurrentsetpointisdisplayedfor
approx.20seconds.
Note
AllanalogueinputsontheroomcontrollercanbereadbytheS-BusviaaRoom
FBoxorviaregistersindependentlyoftheapplication.
Theuseofadigitalroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
3
Digital room controller units
3-5
3.1.2 TechnicaldataforPCD7.L641
RJ 9
Controller
PCD7.L670-xx
PCD7.L641
yellow
green
red
black
LED
comfort mode
Setpoint
potentiometer
temp.-sensor
Occupancy button
Roomcontrolunitwithtemperaturesensor,setpointsettingandilluminatedpresence
sensor.
Pin allocation
Interface Terminal Description
Serialbus RC Theconnectiontotheroomcontrollerismadewiththe
PCD7.L670-xxdirectlytothecontroller,orwhereexten-
sionmodulesareusedforlightandshade,tothelast
module.ThePCD7.L670-xxconnectingcableisprecon-
guredatbothendsandiseither10,30or50mlong.
Themaximumlengthbetweentheroomcontrollerandthe
roomcontrolunitmustnotexceed50m.
Functions
Function Description
Sensor Roomtemperaturesensor.Measurementrange0…40°C.
Setpointsetting Tosetacongurablesetpointdisplacement.Thesetting
isenteredviaapotentiometer.Therangeisconvertedinto
+/-6stepsandpassedtotheroomcontroller.Thebase
set point held in the room controller can be increased or
decreasedinsteps.Thestepsizeisstoredintheroom
controllerconguration.SeedescriptionofCongFBoxor
registers(reg.104).WhenthePlus,SetandMinuskeys
arepressedtogether,thecurrentsetpointisdisplayedfor
approx.20seconds.
PresenceSensor Thepresencesensorcanbeusedtochangetheoperating
modemanuallytoComfortorStandby/unused.InComfort
mode,thesemi-transparentsensorlightsup.
Note
AllanalogueinputsontheroomcontrollercanbereadbytheS-BusviaaRoom
FBoxorviaregistersindependentlyoftheapplication.
Theuseofadigitalroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
3
Digital room controller units
3-6
3.1.3 TechnicaldataforPCD7.L642
RJ 9
Controller
PCD7.L670-xx
PCD7.L642
yellow
green
red
black
LED
comfort mode
Setpoint
potentiometer
temp.-sensor
Occupancy button
Occupancy button
Roomcontrolunitwithtemperaturesensor,setpointsetting,illuminatedpresence
sensorandfancontrol.
Pin allocation
Interface Terminal Description
Serialbus RC Theconnectiontotheroomcontrollerismadewiththe
PCD7.L670-xxdirectlytothecontroller,orwhereexten-
sionmodulesareusedforlightandshade,tothelast
module.ThePCD7.L670-xxconnectingcableisprecon-
guredatbothendsandiseither10,30or50mlong.
Themaximumlengthbetweentheroomcontrollerandthe
roomcontrolunitmustnotexceed50m.
Functions
Function Description
Sensor Roomtemperaturesensor.Measurementrange0…40°C.
Setpointsetting Tosetacongurablesetpointdisplacement.Thesetting
isenteredviaapotentiometer.Therangeisconvertedinto
+/-6stepsandpassedtotheroomcontroller.Thebase
set point held in the room controller can be increased or
decreasedinsteps.Thestepsizeisstoredintheroom
controllerconguration.SeedescriptionofCongFBoxor
registers(reg.104).WhenthePlus,SetandMinuskeys
arepressedtogether,thecurrentsetpointisdisplayedfor
approx.20seconds.

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
3
Digital room controller units
3-7
Function Description
PresenceSensor Thepresencesensorcanbeusedtochangetheoperating
modemanuallytoComfortorStandby/unused.InComfort
mode,thesemi-transparentsensorlightsup.
Fan control Thefanselectionswitchcanbeusedtosetthefanspeed
manually.Theroomcontrollercanonlyswitchtothe
desiredstepifthisisallowedbythefanoperatingwindow.
SeedescriptionofCongFBoxorregisters(reg.63,64)
Note
AllanalogueinputsontheroomcontrollercanbereadbytheS-BusviaaRoom
FBoxorviaregistersindependentlyoftheapplication.
Theuseofadigitalroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
3
Digital room controller units
3-8
3.1.4 TechnicaldataforPCD7.L643
RJ 9
Controller
PCD7.L670-xx
Set
Display
PCD7.L643
yellow
green
red
black
temp.-sensor
Occupancy button
HEVAC function
Roomcontrolunitwithtemperaturesensor,functionkeysanddisplayforHeaVAC
functions.
Pin allocation
Interface Terminal Description
Serialbus RC Theconnectiontotheroomcontrollerismadewiththe
PCD7.L670-xxdirectlytothecontroller,orwhereexten-
sionmodulesareusedforlightandshade,tothelast
module.ThePCD7.L670-xxconnectingcableisprecon-
guredatbothendsandiseither10,30or50mlong.
Themaximumlengthbetweentheroomcontrollerandthe
roomcontrolunitmustnotexceed50m.
Functions
Function Description
Sensor Roomtemperaturesensor.Measurementrange0…40°C.
Setpointsetting Tosetacongurablesetpointdisplacement.Setin+/-6
stepsviathedisplay.Thebasesetpointheldintheroom
controller can be increased or decreased in steps. The
stepsizeisstoredintheroomcontrollerconguration.
SeedescriptionofCongFBoxorregisters(reg.104).
WhenthePlus,SetandMinuskeysarepressedtogether,
thecurrentsetpointisdisplayedforapprox.20seconds.

Saia-Burgess Controls AG
Manual for PCD7.L6xx room operator units │ Document 26-859 ENG07 │ 2015-06-04
3
Digital room controller units
3-9
Function Description
PresenceSensor Thepresencesensorcanbeusedtochangetheoperat-
ingmodemanuallytoComfortorStandby/unused.The
operatingmodeisshowninthedisplay.Thepersonicon
outsidethelittlehouseindicatesnon-use;ifthisiconis
ashing,thecontrollerisinStandbymode.InComfort
mode,thepersoniconmovesintothehouse.
Fan control TheHeaVACmenucanbeusedtosetthefanspeed
manually.Theroomcontrollercanonlyswitchtothe
desiredstepifthisisallowedbythefanoperatingwindow.
SeedescriptionofCongFBoxorregisters(reg.63,64)
HeaVAC functions
ThedesiredfunctionisactivatedbypressingandholdingtheovalSETkey(for
approx.2seconds).Theactivefunctionisshowninthedisplaybytheashingicon.
Thesettingcanbechangedwiththeup/downarrowkeys.Ashortkeystrokeapplies
thecurrentsetting.
Note
AllanalogueinputsontheroomcontrollercanbereadbytheS-BusviaaRoom
FBoxorviaregistersindependentlyoftheapplication.
Theuseofadigitalroomcontrolunitmustbeindicatedintheconguration.
SeedescriptionofCongFBoxorregisters.
This manual suits for next models
2
Table of contents
Other SBC Control Panel manuals
Popular Control Panel manuals by other brands

ADT
ADT Honeywell Domonial QUICK CONSUMER REFERENCE GUIDE

Balboa
Balboa GL Series Quick reference guide

HST
HST HP101 User & installation manual

Stramatel
Stramatel Multisport 452 operating instructions

Harris
Harris NUCLEUS Installation and operation manual

Eaton
Eaton Greengate LiteKeeper 8 installation instructions