SCHEIDT & BACHMANN entervo.lane Application guide

entervo.lane – Control Device
Device Manual
Language: English
Article No.: 81 03111 0 (-)
QM: D - Q - S
© Scheidt & Bachmann GmbH
Parking Solutions
Breite Strasse 132
41238 Moenchengladbach
Germany
www.scheidt-bachmann.com
Subject to change


Author: Peter Schiffer
Modification log:
Refer to chapter "Record of Revisions"
entervo and the entervo logo are trademarks of the Scheidt & Bachmann GmbH.
This manual, including all of its component parts, is copyright protected. Scheidt &
Bachmann GmbH reserves all rights to its contents. Any use not expressly approved
by copyright law is subject to prior approval by Scheidt & Bachmann GmbH. This ap-
plies particularly to copying, processing, translations and microfilming, as well as to
storage and data processing in any electronic systems.
All contents of this manual shall be treated confidentially and shall not be transferred
to any third party, either for their own commercial use or for any other client.
Since all information and facts are subject to technical changes, any liability for the
data contained is hereby disclaimed. Modifications of technical details, in terms of in-
formation and illustrations are reserved. Make sure to follow the updating index.
Scheidt & Bachmann GmbH cannot be held responsible for direct damage and/or pos-
sible consequential damage due to misuse by the customer or by third parties and for
any damage out of or in connection with the provision of the manual. The limitation of
liability does not apply to claims under the Product Liability Act (ProdHaftG) or any
respective applicable national law and/or claims, where the liability is mandatory pur-
suant to applicable law.
© 2020 Scheidt & Bachmann GmbH, Germany
Parking solutions
Breite Straße 132
41238 Moenchengladbach
www.scheidt-bachmann.com
Subject to change.


© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
1
entervo.lane - Control Device, 81 03111 0 (-)
Contents
1About this Manual .......................................................... 3
2Safety............................................................................. 4
2.1
Signal Words and Symbols Used.................................. 4
2.2
General Safety Instructions......................................... 5
3Introduction ................................................................... 6
3.1
Intended Use ............................................................... 6
3.2
Energy and Environmental Aspects ............................. 6
4Product Description........................................................ 7
5Mounting, Connection and Putting into Operation .......... 8
5.1
Pole Mounting ............................................................. 8
5.1.1
Condition of Subsoil ...................................................... 9
5.1.2
Required Fixtures ......................................................... 9
5.1.3
Tools needed ............................................................... 9
5.1.4
Procedure .................................................................... 9
5.2
Connections............................................................... 10
5.2.1
Schematic Diagramme with entervo.barrier ................... 11
5.2.2
I/O Expander ............................................................. 12
5.2.3
entervo.lane Operating Module (Baseboard PTL40) ......... 15
5.3
Putting into Operation ............................................... 16
5.3.1
Configuration Steps at the Cell Computer ...................... 16
5.3.1.1
Add entervo.lane to the System Geometrie and
Configure Device .................................................... 17
5.3.2
Configuration Steps at the Field Device ......................... 17
5.3.3
Change Configuration Parameters................................. 20
6Maintenance and Servicing........................................... 21
6.1
Housing ..................................................................... 21
6.2
Display ...................................................................... 21
6.3
Scanner ..................................................................... 21
6.4
Stainless Steel Stand ................................................. 21
6.5
Barcode Positioner made of Acrylic Glass .................. 22
7Spare Parts .................................................................. 23
8Disposal ....................................................................... 24
8.1
Disposal by Scheidt & Bachmann............................... 24
9Technical Specifications ............................................... 25
9.1
Dimensions................................................................ 26

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
2
entervo.lane - Control Device, 81 03111 0 (-)
10 Index ........................................................................... 27
11 Record of Revisions...................................................... 29
12 Notes............................................................................ 30

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
3
entervo.lane - Control Device, 81 03111 0 (-)
1About this Manual
This manual is part of the product. Please read this manual carefully before
mounting and commissioning of the product and keep it for future reference.
This manual is aimed at the following target groups:
Service technician who install, maintain and repair the equipment
Car park operators
Operating and service personnel
Maintenance personnel
The tasks described in this manual must only be conducted by special-
ized personnel or people with appropriate training!

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
4
entervo.lane - Control Device, 81 03111 0 (-)
2Safety
2.1 Signal Words and Symbols Used
The following signal words are used to indicate risks:
Indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
DANGER
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided,
could result in minor or moderate injury.
CAUTION
This refers to information or a potential risk that may lead
to property damage.
NOTICE
The signal words listed above are often used in combination with one or more
of the following symbols:
Note / General information
Wear protective clothing!
Wear protective gloves!
Before carrying out work on this unit, disconnect the power supply
network!
General warning that must be observed!
Warning of dangerous electrical power!
Caution: Considerable weight!

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
5
entervo.lane - Control Device, 81 03111 0 (-)
2.2 General Safety Instructions
Read and understand all instructions!
The device conforms to the relevant safety regulations. Repairs must be
carried out by specially trained S&B staff only. Improper repairs can re-
sult in serious danger to the user.
The device may only be opened and maintained by people who have been
trained and informed in detail about all safety instructions by
Scheidt & Bachmann.
Only use original spare parts or parts to prevent subsequent damage.
The assembly, installation and maintenance must be carried out by per-
sonnel trained by Scheidt & Bachmann.
The generally accepted rules of electric engineering as well as the gener-
ally accepted rules of mechanical engineering shall be binding for all work
performed on the device!
The requirements for the installation location must be strictly observed.
All national and regional requirements for fire protection must be consid-
ered.
Make all connections according to the system specifications and stand-
ards.
All branch circuits for hard-wired units must be suitable for the unit rat-
ings.
All external DC sources need to be in compliance with the “Limited Power
Source” or “Class 2” requirements. All internal DC sources are already in
compliance.
Replace fuses with the same type and rating.
Never perform any interventions, modifications or changes on the device.
The installation of optional equipment to be installed on-site must only be
carried out by persons trained by Scheidt & Bachmann by using conver-
sion kits.
Do not allow any electrically conductive objects to fall inside the device.
These objects can cause short circuits and damage the device.
Do not store flammable liquids in the housing.
Restart the device in case of an unexpected malfunction. If the device
then does not operate, please contact one of the Scheidt & Bachmann
service points.
The following notes relate to the scanner devices:
The scanners function with the help of an LED positioning aid. Laser tech-
nology which may endanger the eyes is not used.
Only scanners with an LED positioning aid authorised by
Scheidt & Bachmann may be used.
Use the scanner only as specified in the manual.
No liability is accepted for hazards caused by self-procured and self- in-
stalled laser scanners.

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
6
entervo.lane - Control Device, 81 03111 0 (-)
3Introduction
3.1 Intended Use
The device is intended exclusively for checking parking media. A barcode
reader for 1D parking tickets and 2D e-tickets, as well as an RFID reader are
integrated for this purpose. The option of connecting external technologies,
such as IP-based Kathrein UHF readers or LPR cameras, allows the range of
applications to be expanded. When valid parking media are detected, the
connected barrier is opened via the integrated I/O interface.
Media processing technologies are integrated individually according to pro-
ject requirements.
The device is designed to be operated from a vehicle and is suitable for both
indoor and outdoor installation.
Disclaimer
Any other use or extended use is considered to be use other than intended.
The manufacturer declines to bear any responsibility for damage resulting
therefrom. Any modifications are only permitted with the manufacturer’s ret-
rofit kits.
The device must only be commissioned and operated if it is in proper working
condition. Every instance of misuse leads to the termination of the warranty,
guarantee and general liability of the manufacturer.
The device must be installed by an authorised electrician, who is responsible
for observing existing standards and regulations.
3.2 Energy and Environmental Aspects
This manual contains instructions for the installation and operation of Scheidt
& Bachmann products and for the disposal of packaging, waste, consumables
and the like as well as instructions for the disposal of the described Scheidt &
Bachmann product at the end of its use.
These instructions supplement existing legal regulations. Irrespective of the
instructions in this manual, those responsible for installation, operation and
disposal are obliged to comply with local, regional and national safety, envi-
ronmental and waste disposal regulations.

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
7
entervo.lane - Control Device, 81 03111 0 (-)
4Product Description
Fig. 1: entervo.lane
The device consists of the following components:
Control device, identical construction to the door reader “entervo.key”
Stainless steel pole, optionally barcode positioner made of acrylic glass
Printed circuit board “IO Expander” for the direct connection of an S&B
barrier
(This circuit board is located in the lower part of the pole)

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
8
entervo.lane - Control Device, 81 03111 0 (-)
5Mounting, Connection and
Putting into Operation
5.1 Pole Mounting
NOTICE
Before mounting the pole, the I/O Expander must be connected (see chap-
ter 5.2.2). The circuit board is pushed into the stand from below with a spe-
cial fixture and fixed with two knurled screws.
Concrete foundation C 20/25
Curb height between 130 and 170 mm
Attention: Frost foundation must be guaranteed!
Cable or conduit outlet area
Curb
Driveway
4 mounting holes Ø 16 mm
Fig. 2: Pole mounting
91
Ø 16
169,5
230
600
600
182
152

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
9
entervo.lane - Control Device, 81 03111 0 (-)
5.1.1 Condition of Subsoil
The installation will be on a site to be created, according to the
Scheidt & Bachmann GmbH (L x W x D = 600 mm x 600 mm x 800 mm and
depth on regional conditions to ensure frost protection). The drilling depth is
determined by the dowel norm. Note the plumbline alignment.
5.1.2 Required Fixtures
WARNING
Toppling device!
Significant risk of accident in case of improper fastening!
-Careful use of high-quality fastening materials is imperative!
Fastening-parts kit:
The unit is supplied with a fastening-parts kit containing the following parts:
For mounting the stand:
4 threated rods made of stainless steel M10*150 FIS A A4 NO.090448
4 washers made of stainless steel M10 200HV ISO 7093-1
4 cap nuts made of stainless steel M10 DIN 1587-1.4301
To install the threaded rods you also need the UPAT injection mortar UPM 44-
360, which is not included in the scope of delivery.
For mounting the control device on the pole:
4 stainless steel Torx flat head screws M 4*16
5.1.3 Tools needed
You need the following tools for the assembly and installation:
Impact drill; better: Rotary hammer
12-mm concrete drill
17-size mouth or ring spanner
NOTICE
Follow the safety instructions of the tool manufacturer.
5.1.4 Procedure
WARNING
Flaking concrete splitter and whirling dust!
Be careful when drilling!
-Wear protective clothing when drilling!
-Never wear loose clothing, as it may become entangled in the moving
parts of the hammer!

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
10
entervo.lane - Control Device, 81 03111 0 (-)
B
Mark and drill the mounting holes (diameter of 12 mm, depth of ap-
prox.140 mm).
C
Clean holes thoroughly.
D
Inject mortar from bottom to top without creating any air bubbles.
E
Insert rods: Screw in rods with the thread slowly. The rod must stick out
15 mm from the drill hole. Do not move any more until the curing time
has expired.
F
Screw the base plate of the stand with the cap nuts and washers after the
curing time has expired.
The mounting of the stand is completed.
5.2 Connections
Power supply
The power supply is provided by 24V DC voltage (LPS/Limited Power Source),
which is provided by suitable external devices. The voltage can, for example,
be provided by the "entervo.barrier" or via an additional kit in the AS30 or
AS32 barrier. The connection point for the power supply is the I/O Expander
board.
Only power supply units which meet the requirements for a limited power
source (LPS) are permitted!
Network connection
The network connection is established via an RJ45 socket.
Barrier connection
The connected barrier is controlled and monitored via the I/O Expander board.
Inductive loops
The signals from 2 double detectors can be read in via corresponding inputs
on the I/O Expander.
Project in and outputs, Relays
For project-specific requirements, 8 digital inputs and 8 digital outputs are
available on the I/O Expander board. Furthermore, 4 relays with changeover
contact are available (2 relays each on the door reader PCB and 2 on the IO
Expander).
Power supply for optional OEM devices
The I/O Expander board provides 12 VDC (max. 2 A) and 24 VDC (max. 1 A)
for the power supply of optional OEM devices.

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
11
entervo.lane - Control Device, 81 03111 0 (-)
5.2.1 Schematic Diagramme with entervo.barrier
entervo.lane operating panel Network / Ethernet
I/O Expander Mains power
entervo.barrier Inductive loops
Fig. 3: Schematic diagramme
24 VDC (LPS)
Mains / Power
Barrier I/Os
Detector
Ethernet
I2C / 12V

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
12
entervo.lane - Control Device, 81 03111 0 (-)
5.2.2 I/O Expander
Fig. 4: I/O Expander – Installation position
Fig. 5: I/O Explander – Connections
BARRIER
KL395
KL570
KL100
ST365
ST580
ST292
ST385
KL400 KL500
KL590
ST270

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
13
entervo.lane - Control Device, 81 03111 0 (-)
Pos. Connection
Power supply (input voltage LPS)
Pin 1: +24VF
Pin 2: GND24VF
Barrier gate
Pin 1: GND24VF
Pin 2: +24VF_PROTECTED
Pin 3: IN_BARRIER_INDUFA
Pin 4: IN_BARRIERARM_DISCONNECTED
Pin 5: IN_ENDPOSITION_CLOSED
Pin 6: IN_ENDPOSITION_OPENED
Pin 7: OUT_CLOSE_BARRIER
Pin 8: OUT_OPEN_BARRIER
Door contact
Pin 1: +24VF_PROTECTED
Pin 2: IN_DOORCONTACT
Pin 3: GND24VF
Pin 4: GND24VF
Power supply for optional OEM devices
Pin 1: GND12V
Pin 2: +12V
Pin 3: GND24VF
Pin 4: +24VF
Pin 5: GND24VF
Pin 6: +24VF
8 x Project outputs
Pin 1: GND24VF
Pin 2: OUT_1
Pin 3: GND24VF
Pin 4: OUT_2
Pin 5: GND24VF
Pin 6: OUT_3
Pin 7: GND24VF
Pin 8: OUT_4
Pin 9: OUT_5
Pin 10: OUT_6
Pin 11: OUT_7
Pin 12: OUT_8
8 x Project inputs
Pin 1: +24VF_PROTECTED
Pin 2: IN_1
Pin 3: +24VF_PROTECTED
Pin 4: IN_2
Pin 5: +24VF_PROTECTED
Pin 6: IN_3
Pin 7: +24VF_PROTECTED
Pin 8: IN_4
Pin 9: IN_5
Pin 10: IN_6
Pin 11: IN_7
Pin 12: IN_8
KL100
BARRIER
KL395
KL570
KL400
KL500

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
14
entervo.lane - Control Device, 81 03111 0 (-)
Pos. Connection
2 x Relay (30VDC / max. 1.0A switching capacity)
Pin 1: Relay 1: relay output / normally open
Pin 2: Relay 1: relay input
Pin 3: Relay 1: relay output / normally closed
Pin 4: Relay 2: relay output / normally open
Pin 5: Relay 2: relay input
Pin 6: Relay 2: relay output / normally closed
Pin 7: +24VF
Pin 8: GND24VF
Fan (not in use)
Intercom Interface (not in use)
Double detector 1
Pin 1: IN_Barrier loop
Pin 2: GND 24VF
Pin 3: +24VF
Pin 4: IN_Device loop
Double detector 2
Pin 1: IN_Additional loop 2
Pin 2: GND 24VF
Pin 3: +24VF
Pin 4: IN_Additional loop 1
I
2
C Interface and power supply for door reader
Pin 1: Chassis_2
Pin 2: SDA
Pin 3: SCL
Pin 4: INT_I2C
Pin 5: GND24VF
Pin 6: +12V
Pin 7: GND
Pin 8: +5V
KL590
ST292
ST580
ST365
ST385
ST270

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
15
entervo.lane - Control Device, 81 03111 0 (-)
5.2.3 entervo.lane Operating Module (Baseboard
PTL40)
Fig. 6: Connectors on the backplane PCB
The two connectors ST10 and ST12 are equipped with push-in connectivity to
accept cables with core end sleeves.
The pin assignment can be found in the following tables:
Pin Description
Plug ST10
1 Power supply: 12V DC
(Do not connect if the power supply is via PoE)
2 Power supply: GND
(Do not connect if the power supply is via PoE)
3 Relay 3: relay output / normally closed
4 Relay 3: relay input
5 Relay 3: relay output / normally open
6 Relay 4: relay output / normally closed
7 Relay 4: relay input
8 Relay 4: relay output / normally open
9 I2C1_SCL_EXT (I
2
C-Bus, Serial Clock)
10 I2C1_SDA_EXT (I
2
C-Bus, Serial Data)
11 INT_IO_EXT
12 GND
13 Optoelectronic output 2: OUT_2_C

© 2020 Scheidt & Bachmann GmbH, Germany Subject to change
Device Manual
16
entervo.lane - Control Device, 81 03111 0 (-)
Pin Description
14 Optoelectronic output 2: OUT_2_E
15 Optoelectronic output 1: OUT_1_C
16 Optoelectronic output 1: OUT_1_E
17 Optoelectronic input 1
(controlled with 12 – 24 V DC (± 5 V)
18 Optoelectronic input 1: GND_IN
19 Optoelectronic input 2
(controlled with 12 – 24 V DC (± 5 V)
20 Optoelectronic input 2: GND_IN
NOTICE
Use the pre-assembled cable to establish the connection between the con-
nectors ST10 on the baseboard PTL40 and ST270 on the IO Expander
board.
Pin Description
Plug ST12 (Ethernet)
1 - 10 Network connection
(Use pre-assembled cable for connection to the RJ45 socket!)
5.3 Putting into Operation
5.3.1 Configuration Steps at the Cell Computer
NOTICE
At least the service pack SP120 for field devices must be installed on the
cell computer! Check the version on the cell computer in the file
c:\dfue\linux\version.ini
.
The following steps must be carried out on the cell computer which
are explained below:
1. Install latest service pack for field devices.
2. Install latest control files for the Configuration Wizard.
3. Use Configuration Wizard to add the field device to the system geometry.
4. Set configuration parameters of the field device.
5. Apply Configuration Wizard settings to the cell computer and then reboot
the cell computer.
Table of contents