  9. SCORPION SCORP 8000 Original operating instructions

SCORPION SCORP 8000 Original operating instructions

1. Control Panel Installation
 The Control Panel is fixed using the two M5 slots in the rear of the box.
Cabling for the Control Panel can either be run inside a cavity

wall with an exit hole directly behind the Control Panel, or
can be run in conduit on the outside of the wall. If using
conduit, the optional mounting box must be used to allow
cable access to the sides of the panel (Fig. 1).
Undo the two small screws at the top of

the panel and carefully remove the front
face, taking care not to pull the cable
between the two parts (Fig. 2).
Connect the cable for each Head Unit to

the appropriate screw terminals (marked
CH1 to CH8) on either side of the rear
entry slot. Note which colour wires have been
used for each terminal (marked A, B, C, and D).
These will connect to the corresponding terminals
in the Head Unit. If using 3-core cable, connect to
terminals A, B, and C only (Fig. 3).
NOTE: Incorrect wiring may lead to damage to
either the Control Panel or the Head Unit.
Cabling
Scorpion can be connected using the following cables to give up to 100m distance

between the Control Panel and each Head Unit:
2 2
a. Fire resistant cables such as FP200 1.5mm (Lapp J-Y(ST)Y 0.5mm ),
or equivalent recommended
2 2
b. Maximum conductor size is 1.5mm , minimum is 0.5mm
c. Screened cable is not required
The connector used in the Head Unit is intended for solid-core conductors for ease

of installation in difficult areas. Stranded cable may be used but would need to be
tinned (soldered) or terminated with a suitable terminal (ferrule) with an external
diameter no greater than 1.5mm.
Each Head Unit requires three (3) conductors (A, B & C). 4-core cable is

recommended.
Cabling must be installed in accordance with local wiring regulations. Scorpion uses

battery power (nominal 7.2V, 2.2Ah).
Tighten the terminal screws.

Mounting
Slots
2. Control Panel Interface
TEST
CLEAR
TEST CLEAR
R E M O T E D E T E C T O R
scorpion
TEST TECHNOLOGY
®
0 0 0 Time IndicatorBattery Low Indicator
RUN Button
STOP Button
Clearing Indicator
UP Button
DOWN Button
Smoke Test Indicator
Display
Clearing Time Button
(recessed)
Smoke Time Button
(recessed)
Display
Indicates:
- Head Unit number (1 - 8)
- Timer (counting up in seconds when the green LED is on)
Display
- Three flashing dots indicates the internal fuse has blown (see Section 8)
UP Button
- Used to select Scorpion Head Unit or adjust timer
- When TEST or CLEAR recessed button is pressed, the UP button increases
the time
DOWN Button
- Used to select Scorpion Head Unit or adjust timer
- When TEST or CLEAR recessed button is pressed, the DOWN button
decreases the time
RUN Button
- Used to start test (smoke generation and/or clearing)
STOP Button
- Used to stop test (smoke generation and start clearing, or to stop clearing,
or to stop timer)
- Press for 3 seconds to activate or deactivate timer
Timer Indicator
- Lights up when timer is active
- The display then indicates the time since smoke generation and/or clearing
cycle started
TEST Indicator
- Test cycle in progress (smoke generated and /or clearing functions)
- Recessed Button: Press with small pointed tool to change smoke duration
CLEAR Indicator
- Clearing (detector purging) in progress
- Recessed Button: Press with small pointed tool to change clearing time
Battery Low Indicator
- Lights up when battery power is low
CAUTION
This product may be used at height.
Exercise great care and wear appropriate PPE (personal
protective equipment) when operating above head height in
order to avoid the risk of injury.
Fig. 2
Fig. 3
Fig. 1
Scorpion Control Panel
Installation & Operation Guide
(Point and ASD Systems)
Scorpion Control Panel
SCORP 8000
(including mounting box)
www.scorpion-tester.com/support
[email protected]
Care of Scorpion Products
Low Battery Indicator - illuminates when battery power

gets low. Tests cannot be made when the low battery indicator
is on and the battery will need to be recharged.
Error - Three (3) flashing dots on the display indicate that

a fault has occurred causing the internal fuse to blow.
TEST
RE M OT E DE TE C TO R
scorpion
TEST TECHNOLOGY
0 0...0
Flashing dots on the display
indicate a fault
CLEAR
®
There are no user serviceable parts in the Scorpion Head Unit which is permanently sealed.

Opening the Head Unit other than as shown in the Installation Guide will invalidate any

warranty.
NOTE: The Head Unit is designed to be permanently installed providing in excess of 240 tests
The Control Panel contains a 500mA fuse which can be replaced if necessary (Littlefuse Surface

Mount NANO2 SLO-BLO 500mA fuse, Manufacturer Part No. 0454.500, or equivalent).
There are no other user serviceable components in the Control Panel.
In the event of failure, any liability for No Climb Products Ltd. shall be limited to

replacement of Scorpion components only.
LI37209-3
Please read the Scorpion Manual
Warnings and Errors
Service / Maintenance
Head Unit
Control Panel
R E M O T E D E T E C T O R
scorpion®
TEST TECHNOLOGY
Spare Fuse
www.acornfiresecurity.com
www.acornfiresecurity.com
3. Battery Charging
Fig. 5
Fig. 6
Locking Ring
Scorpion Battery Pack
(SCORP 50)
Solo Battery Baton
(Solo 760)
Fig. 4
Fig. 7
The Scorpion Battery Pack (SCORP 50) or Solo Battery Batons (SOLO 760) are used to
power the Scorpion System, and must be charged before using Scorpion.
Only the Solo 726 charger should be used for charging Scorpion Battery Packs or Solo Battery
Batons (Fig. 4). Do not connect other types of batteries. Danger of explosion.
Connect the Solo 726 charger to a mains power outlet (100/240V – 50/60Hz) or 12 volt vehicle
accessory socket.
Connect the Scorpion Battery Pack or Solo Battery Baton to the charger via the seven pin
polarised connector and turn the locking ring (Fig. 5-6).
The LED will flash from red to green for around 5 minutes whilst the battery status is checked.
The LED will then turn to red to indicate fast charging, unless the battery is fully charged, in
which case it may go directly to green (ready for use) (Fig. 7).
After fast charging is complete (90 minutes for a fully discharged battery), the charge is
automatically converted to a trickle charge and the LED turns to green (ready for use).
A red flashing LED indicates a faulty battery. Disconnect the battery from the charger and replace with a new battery.
The battery charger and battery can remain connected under a trickle charge for several hours without damage to the battery. This maintains the
battery in a fully charged state, ready for use.
Note: If the battery is not to be used for some time (i.e. within the next day), it is advisable to unplug the charger from the power supply.
To stop charging, disconnect the power plug before removing the battery from the charger.
To obtain the maximum battery life, the Scorpion Battery Pack or Solo Battery Baton should be fully discharged before recharging when possible.
WARNING
Do not attempt to use or charge the battery if either the unit or the
battery connection point are damaged.
Never connect AC and DC power at the same time.
CAUTION
Store charger in a dry place (indoor use only when connected to AC
mains). Danger of fire and electric shock! Do not fast-charge a hot
battery. Allow the Battery Baton, or Scorpion Battery Pack, to cool down
naturally before starting a charge cycle. Allow the charger to cool down
for at least 15 minutes after one fast charge. Stop charging if the Battery
Baton, or Scorpion Battery Pack, becomes too hot during charging
(>55-60°C). Do not leave unattended whilst charging. Only clean with a
dry cloth. Do not attempt to open the charger. Repair permitted only by
authorised dealer.
Battery Batons, or Scorpion Battery Pack, must be stored and charged
in accordance with stated environmental conditions.
Environment: Operating temperatures: 5°C to 45°C / 40°F to 115°F
Storage temperature: -10°C to 50°C / 15°F to 120°F
Humidity: 0-90% RH non-condensing
4. Connecting the Battery 5. Setting TEST and CLEAR Times
7. Test Procedure
 With a Scorpion Battery Pack (SCORP 50), insert the connector at the end of the Battery
Pack to the socket at the bottom of the Scorpion Control Panel. The connectors need to
be aligned before they can push together. Once inserted, twist the collar on the battery
socket clockwise to lock the battery into place.
To remove the battery, twist the collar

anti-clockwise to unlock, then pull gently
to disengage.
When using a Solo Battery Baton (SOLO 760),

a Scorpion Battery Cable (SCORP 60) is
required to connect the battery baton to the
Scorpion Control Panel.
The time that is required for TEST (the time for which smoke is generated) and CLEAR

(ambient air is blown through the detector chamber) can be changed depending on the
system activation time.
TEST (default time is 15 seconds)
CLEAR (default time is15 seconds)
Press and hold the relevant TEST or CLEAR recessed button with a small blunt tool.

The corresponding LED will start to flash.

Press the UP button to increase the time or the DOWN button to decrease the time.

The time is shown on the display.
TEST - time range is 5 to 90 seconds
CLEAR - time range is 10 to 60 seconds
When the required time is shown, release the TEST or CLEAR recessed button. The time

is now set and is saved in the Control Panel for future use. This time is used for all the Head
Units connected to that panel.
NOTE: the CLEAR function is used to purge smoke from the detector to enable it to reset
more quickly. It cannot be used to clean the internal components of the detector.
6. Enabling the Transport Timer
The Transport Time is used in ASD systems, and is the time taken between the start of

smoke generation and the event appearing on the ASD panel.
The Timer is activated / deactivated by pressing and holding the STOP button for 3 seconds.

The Timer Indicator LED flashes fast for 3 seconds to show the timer has been activated,

and flashes slowly for 3 seconds when deactivated.
During a test cycle, the Timer Indicator LED is illuminated and the display shows the time

since the start of smoke generation (counting up).
TEST CLEAR
R E M OT E D E T E CT OR
scorpion
TEST TECHNOLOGY
®
0 0 0
RUN Button
STOP Button
Clearing Indicator
UP Button
DOWN Button
Smoke Test Indicator
Clearing Time Button
(recessed)
Smoke Time Button
(recessed)
TEST STAGE
Button
POINT
ASD
START
STOP
STOP
START
STOP
STOP
SMOKING CLEARING
Smoke ON
Stops Smoke and starts Clearing
Clearing ON
Clearing ON
Clearing OFF
Test Ends
Test Ends
Test Ends
Shows Head Number
Shows Head Number
Shows Head Number
Test Ends
Test Ends
Test Ends
Shows time counting up
Shows stopped time
Shows stopped time
Smoke ON and Timer starts
Stops Smoke and Clock - starts Clearing
Clearing ON
Clearing ON
Stops Clock
Stops Clearing
Shows Head Number
Once test has stopped (either run its course
or stopped manually), any button will clear
the time from the display and allow the next
head to be selected
UP or
DOWN
DISPLAY
Select the head to be tested using the UP and DOWN buttons (head number is shown
on the display). The Control Panel will allow selection of up to 8 heads, even if no head is
connected to that port.
 Press the START button to begin the test.

 The test will run based on the times set for TEST and CLEAR (see Section 5).

The LED indicators on the front panel illuminate to show the stage of the test i.e. SMOKE
or CLEAR. Once the test has been completed, the system will stop automatically.
 If a manual stop is needed, then press the STOP button. Depending on the stage of the test,

the STOP button will have the effect shown in the table below.
www.acornfiresecurity.com
www.acornfiresecurity.com

Popular Control System manuals by other brands

Gamma Vacuum Digitel MPC 635941 Technician manual

Gamma Vacuum

Gamma Vacuum Digitel MPC 635941 Technician manual

Svarog 105 PLASMA CNC operating manual

Svarog

Svarog 105 PLASMA CNC operating manual

Varifan SVIM-1LE user manual

Varifan

Varifan SVIM-1LE user manual

Crestron 4 Series quick start guide

Crestron

Crestron 4 Series quick start guide

Woodbridge B0940S installation manual

Woodbridge

Woodbridge B0940S installation manual

Nxg VMS100 user guide

Nxg

Nxg VMS100 user guide

Beacon BM5 Series owner's manual

Beacon

Beacon BM5 Series owner's manual

Techno CNC Systems Venture Series user manual

Techno CNC Systems

Techno CNC Systems Venture Series user manual

TouchTronics 1210-R Service manual

TouchTronics

TouchTronics 1210-R Service manual

Norac UC7 installation manual

Norac

Norac UC7 installation manual

ATEN VKT100 user manual

ATEN

ATEN VKT100 user manual

Kongsberg ACS500 instruction manual

Kongsberg

Kongsberg ACS500 instruction manual

Calimet CM9-2 Installation and owner's manual

Calimet

Calimet CM9-2 Installation and owner's manual

HORNER HE500OCS050 user manual

HORNER

HORNER HE500OCS050 user manual

BriskHeat LYNX instruction manual

BriskHeat

BriskHeat LYNX instruction manual

Philips SpaceWice user manual

Philips

Philips SpaceWice user manual

Conviron CMP6050 Operator's manual

Conviron

Conviron CMP6050 Operator's manual

DANHAG APP-control operating manual

DANHAG

DANHAG APP-control operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.