DANHAG APP-control User manual

APP - Control
Version v10.x
as of 02.2018
Operating manual

Front view
Antenna
Status LED
Release
SIM card
SMA
connection
Rear view
Release
(connector I)
PIN1
PIN8
GPS LED
Release
(connector II)

Table of content
1 Scope of delivery.............................................................................................
2 Safety instructions........................................................................................... 6
3 Intended use................................................................................................... 6
4 Obligation and liability....................................................................................7
Malfunction..................................................................................................... 8
6 Disposal........................................................................................................... 8
7 Declaration of conformity............................................................................... 8
7.1 Typengenehmigung..............................................................................8
8 Device description...........................................................................................9
8.1 Difference BASIC / W-BUS / E-BUS........................................................9
8.2 Alarm function...................................................................................11
8.3 Switching acknowledgment................................................................12
8.4 Status LED, GPS LED............................................................................12
9 SIM-card........................................................................................................ 13
9.1 Inserting the SIM card........................................................................ 13
10 Inputs and Outputs (connector I)................................................................14
11 electrical connection................................................................................... 16
11.1 connection to the heater..................................................................16
11.2 Connection of ext. button.................................................................17
12 Accessories connection...............................................................................18
12.1 External temperature sensor............................................................18
12.2 GPS-receiver..................................................................................... 18
13 Start up....................................................................................................... 20
14 Configuration.............................................................................................. 21
14.1 Table parameter ..............................................................................24
14.2 Configuration with SMS configurator................................................2
14.3 Configuration with mobile phone ....................................................2
14.4 Delete a phone number ...................................................................2
14. Reset................................................................................................ 2
14.6 SMS-commands................................................................................26
1 Trouble shooting......................................................................................... 28
16 Manufacturer.............................................................................................. 29
17 technical data.............................................................................................. 29
18 Copyright..................................................................................................... 29
19 Installation location..................................................................................... 30


APP-control v10.x
1 cope of delivery
•APP-control
•GSM-antenna (straight)
•connection line (14-pole connector)
•operating manual
optional available accessories
•vehicle-specific cable harnesses
•indoor window antenna
•Antenna adapter (FME to SMA)
•GPS-receiver
•external temperature sensor
- 32
Prior to insertion of the SIM card please deactivate the PIN
request and the mailbox and delete all telephone numbers
that may be stored.
The operation of the GSM remote control will require any
SIM card which is not included in the scope of delivery.

APP-control v10.x
2 afety instructions
Prior to the commissioning ot the device please read this operating manual
completely. Additionally you have to observe the generally valid and the local
regulations for accident prevention and environmental protection. Keep the
operating manual. Do not operate the device in a surrounding where
flammable gases, vapors, liquids or dust are existing or my exist.
3 Intended use
The APP-control allows the switching of any device per APP, SMS or call. The
APP-control is designated for private use and not for commercial purposes. The
APP-control has to be used exclusively according to the instructions of thes
operating manual. The manufacturer is not liable for damage which are caused
by inappropriate use or incorrect operation.
6 - 32
Do not use the APP-control if due to a malfunction danger
and / or damage may occur.
The installation must only be carried out by a qualified
technican.

APP-control v10.x
4 Obligation and liability
The APP-control has been developed and manufactured according to the
current technical status and the recognized safety rules. It cannot be assured,
however, that the APP-control will operate as intended under all circumstances,
at any time and under all conditions.
The DANHAG APP-control is manufactures in compliance with the EU directive
2011/6 /EG (RoHS 2). this directive determines the use of hazardous material
in devices and components.
The compliance with the prescribed EMC limit values was confirmed by an
independent EMC testing laboratory.
Our products are recorded in the register for waste electrical equipment and
meet the requirements of the relevant, applicable CE regulations. We confirm
the observation of European standards on our devices by the CE marking. WEEE
Reg. No.: DE 33181931
We only use sales packaging licensed by the disposal company
“Zentek duales System”.
7 - 32
Do not use the APP-control for the switching of life-
support systems or devices with an emanating danger due
to an uncontrolled switching on and off.

APP-control v10.x
5 Malfunction
The APP-control must taken out of service immediately when it might be
assumed that a safe operation cannot be guaranteed any more. All appropriate
measures must be taken to exclude an unintentional re-commissioning. Only a
qualified person os allowed to perform a repair.
6 Disposal
This product must be taken to an official collecting point for disposal. You can
also give back the product to the manufacturer for ecological disposal.
7 Declaration of conformity
The device is complying with the EU regulation 2004/108/EG (electromagnetic
compatibility). Applied standards: EN 0498 / 2011
7.1 Typengenehmigung
8 - 32
E1 10R - 058021
This product must kept out from the domestic waste.
Please dispose the product according to the applicable
legal provisions only.

APP-control v10.x
8 Device description
8.1 Difference BA IC / W-BU / E-BU
The versions are supporting different output signals as shown at the table.
output signal / Version output
BA IC W-BU E-BU PIN
+12V +12V +12V 2
ground ground ground 3
+12V W-BUS 3 E-BUS 3 1
W-BUS 4 E-BUS 4
W-BUS E-BUS
W-BUS 6 E-BUS 6
E-BUS 7
E-BUS 8
9 - 32
The APP-control "W-BUS" and "E-BUS" are supporting
different output signals. An overview about the signal
needed for your vehicle or heater
can be found at our website: www.danhag.de

APP-control v10.x
8.1.1 tatus
You can query the current status of the heater by sending a sms with the text
"INFO" to the APP-control.
BA IC, W-BU
The status displays the state of the APP-control.
E-BU
The E-BUS version communicates with the heater and can display the current
state of the heater.
8.1.2 tatus messages
E-BU only
Status messages are deactivated with the default settings.
When status messages are enabled, you will be notified via SMS either when:
•the heater was started successfully
•the heater could not be started
•the heater was turned off
10 - 32
Status messages are not supported from all vehicles /
heaters.

APP-control v10.x
8.1.3 Operating time
You can configure a default run-time via SMS. If you switch on the heater by
APP, SMS or Call, the heater will use this run-time. If you switch the heater by
APP or SMS, you can define a run-time of 10, 20, 30, 40, 0 or 60 minutes. The
heater will run for this time once and than uses the default value again.
E-BU only
The APP-control queries the operating-time from the vehicles board-computer.
If the operating-time can't be queried, the default value will be used.
8.2 Alarm function
The APP-control is equipped with an alarm input which can be connected to an
existing alarm system.
After connecting the power supply to the APP-control, the voltage level on the
alarm input will be stored (0 or +12V). As soon as this level changes, the alarm
will be triggered and all stored numbers are informed by call and SMS.
11 - 32
Factory installed alarmsystems are often integrated into
the vehicles bus-system. Further information about how to
connect these system can be found at our website:
www.danhag.de

APP-control E-BUS v10.x
8.3 witching acknowledgment
8.3.1 witching by call
When switching the APP-control by call, you will hear a dial tone. During this
time the caller's ID will be analyzed. In case of a valid phone number th
switching operation will be released and you will hear a busy tone.
8.3.2 witching by APP or M
You can query the current switching state of the APP-control by sending a SMS
with the text “INFO” to the APP-control.
8.4 tatus LED, GP LED
Die LEDs zeigen den aktuellen Zustand des Gerätes und des GPS-Empfängers an.
tatus LED
flashing green (every 3s) Standby (logged in)
lighting green Heater is switched on
flashing red Network search (not logged in)
lighting red fault
GP LED
off GPS-receiver off
flashing red (every 1s) no GPS-reception
flashing green (every 1s)
GPS-reception OK
12 - 32

APP-control v10.x
9 IM-card
Any SIM card is required for the operation of the APP-control (Prepaid or
subscription).
9.1 Inserting the IM card
•Disconnect the power supply from the device
•remove the SIM card holder
(Pleas press the release button“ slightly to release the holder)
•insert the SIM card into the holder
•push the SIM card into the device
•connect the power supply
13 - 32

APP-control v10.x
10 Inputs and Outputs (connector I)
PIN color description function
1 yellow Switching output 1 W-BUS, E-BUS
2 black Switching output 2 Output +12V, max. 1A
3 purple Switching output 3 ground, max. 00mA
4 output GND output GND 1KOhm for ext. LED
green input +12V Input for ext. button / switch
Button: one impulse (approx. 1s) is
turning the Switching outputs
alternately on and off ("on" for
preset time)
witch: as long as +12V are applied
the Switching outputs are activated
(max. for preset time)
6 output +12V output +12V for ext. Taster
7 red power supply • +12V (fuse with 5A)
8 brown ground • Ground connection
9not in uses
14 - 32

APP-control v10.x
PIN color description function
10 Relais nc
11 Relais com
12 Relais no
13 blue input alarm
+12V / GND
Input for an existing alarm system
(see alarm function)
14 orange input ignnition
1 - 32
The inputs and outputs marked with "•" must be
connected for the basic functionality of the device. All
further connections can be used optionally.

APP-control v10.x
11 electrical connection
11.1 connection to the heater
11.1.1 heater without radio remote control
The APP-control comes with an universal connection cable. Connect the APP-
control to the power supply (red +12V, brown ground) and the yellow wire to
the control-pin of the heater.
11.1.2 heater with radio remote control
The APP-control is connected to the already existing receiver of the remote
control, using the y-cable which is included into delivery. The Y-cable also
ensures the power supply of the APP-control.
•disconnect the original cable from the receiver
•connect the y-cable to the receiver
•connect the original cable to the y-cable
•connect the APP-control to the Y-cable
16 - 32
An overview about the mounting place of the receiver can
be found at our website:
www.danhag.com

APP-control v10.x
11.2 Connection of ext. button
The button / switch is connecting PIN6 (+12V) with PIN of the 14-pole
connector. There is a ground signal on PIN4 present as long as the switching
output is active. PIN4 has a resistor integrated to drive a LED directly.
11.2.1 Difference between button and switch
Button: Pressing the button shortly (approx. 1s) will switch on the heater for
the preset time. If you want to switch of the heater you have to press the
button once again.
witch: The heater is running as long as the switch is closed, but max. for the
preseted time.
17 - 32
white
green
brown
DANHAG button
14pol. connector of APP-control
1 7
14 8

APP-control v10.x
12 Accessories connection
The 4-pole accessories connection (connector II) is located at
the rear side of the device. You can connect an external temperature
sensor or an GPS-receiver. If you want to connect both devices, you
willl need a Y-cable which is available as accessory.
12.1 External temperature sensor
The measured values are far more accurate.
12.2 GP -receiver
The APP-control supports an external GPS-receiver which can be connected to
the aux-socket at the back of the module. If the ignition is switched on the
position is determined about every 1 second and can be queried via SMS. If the
ignition is switched off, the GPS-receiver is activated during determining the
position only.
You will get a SMS containing the current coordinates of the car as well as a link
to “google maps” which shows the current position on the map.
18 - 32
When you connect an external temperature sensor, the
sensor must be activated via SMS. Please send a sms with
the following text to the APP-control: 12345;35=1;#

APP-control v10.x
Ignition ON
You can query the position via SMS “GPS”.
If the ignition is switched on the position is determined about every 1 second. If
The Ignition is switched off, you will get the last known position.
Ignition OFF
You can query the current position via SMS “XGPS”.
The GSP-receiver is activated for about 3 minutes to determine the position.
19 - 32
The GPS-receiver must be activated when used for the first
time. Please refer to the manual delivered with the GPS-
receiver.
If you want to update the position when the ignition is
turned off, you will have to send a SMS with the text
„XGPS“ to the APP-control. The GPS-receiver is turned on
for about 3 minutes and determines the current position.
If the receiver doesn't get any valid information, the last
known position will be used.
The „E-BU “ version determines the current state of the
ignition via the vehicles data-bus. You will not have to
connect the ignition separately.

APP-control v10.x
13 tart up
Prior to start-up please read the complete instruction manual.
•Disable the PIN-request of the SIM-card
•insert the SIM-card into the APP-control
•connect the APP-control to the 14-pole connector
•wait until the APP-control is logged-in (Status-LED flashing green)
•configure the APP-control
After connecting the power supply , the APP-control will perform a selftest. The
LED will be lighting red for approx. 4 seconds and then begins to flash red
(network search). As soon as the APP-control is logged in into the GSM
network, the LED will be flashing green. Now, the APP-control is ready to
operate and can be configured.
20 - 32
Please deactivate the PIN query prior to the insertion of
the SIM card. Otherwise the APP-control cannot log in into
GSM network. Therefore please insert the SIM card – if
required - in a "normal" mobile phone and use the
function "Deactivate PIN query".
Table of contents
Popular Control System manuals by other brands

WAREMA
WAREMA LONMSE 2M230I Operating and installation instructions

Woodward
Woodward easYgen-1700 Operation manual

WattMaster
WattMaster VAV OE391-05 Technical guide

Seav
Seav LRX 2035 NEW manual

Roger Technology
Roger Technology Agilik AG/004 Use and maintenance manual

Rockwell Automation
Rockwell Automation MSR300 instruction manual