Features:
•
4 High intensity 1
-
watt
LEDs
•
Synchronize u to
20
units
•
23
Different rogrammable flash atterns
•
W
ater
roof
(IP6
7
) and vibration
-
resistant
•
O erating life rated 100,000 hours
•
Fl
exible in ut ower (10~30 VDC)
Parts List:
High Intensity 1W LED Module ............... x1 Mounting flange ...................................... x1
Mounting screws ..................................... x2 Manual .................................................... x1
Rubber gasket ........................................ x1
Introduction:
The ENFORCER SL-1311-MA/B is a High Intensity 1Wx4 LED Module strobe light that features
next generation LED technology with four 1-watt LEDs in a very com act ackage.
This strobe light offers 23 selectable flash atterns, otted circuitry to be water roof (IP67) and
vibration-resistant, multi-unit synchronization (simultaneous or alternating), and 10~30 VDC
o erating voltage, making it excellent for a wide range of security and informative a lications.
Speci ications:
Housing sha e Rectangular
Number of LEDs 4 High intensity 1W LEDs
Current draw* 560mA@12VDC / 300mA@24VDC
O erating voltage 10~30 VDC
Electrical rotection Reverse olarity rotected
O erating life LEDs rated at 100,000 hours (>11 years)
Number of flash atterns 23 ( rogrammable)
Synchronization Simultaneous or alternating u to 20 units
IP Rating IP67
O erating tem erature -22°~150° F (-30°~65° C)
Dimensions 413/16"x15/8"x11/8" (122x41x29 mm)
*Figures shown are maximums. Current draw will vary de ending on flash attern.
Dimensions:
4
13
/
16
" (122mm)
1
5
/
8
"
(41mm)
3
/
4
"
(19mm)
3
/
8
"
(10mm)

ENFORCER
®
High Intensity 1Wx4 Blue LED Module
SECO-LARM
®
U.S.A., Inc 3
Wiring and Installation:
Wiring the strobe:
1. Black wire: Connect to ower su ly negative (-) terminal or ground.
2. Red wire: Connect to ower su ly ositive (+) terminal 10~30 VDC.
NOTE: It is recommended to fuse each unit @ 1A.
3. Yellow wire:
•Programming Flash Patterns: Connect an o tional SPST momentary switch such as
ENFORCER
SS-032Q to rogram the strobe light flash atterns. See connection diagram
above, and Flash Patterns on age 4 for more instructions.
•Synchronizing Multiple Units: Connect the yellow wires of multi le units to synchronize
their flash atterns.
NOTE: All units must be set to the same flash attern.
•Connect the yellow wires of additional units to synchronize u to 20 strobes.
4. White wire (o tional to set alternating flash):
•Alternating Flash: Strobes can synchronize in an alternating flash attern. For exam le,
when Strobe A flashes ON, Strobe B will flash OFF, etc. Synchronize all strobes. Connect
the white wire to the ower su ly only for strobes that should alternate with the others.
Mounting the strobe:
1. Choose a mounting surface and drill a hole large enough to allow strobe wires to ass.
2. Feed the wires through the hole in the rubber gasket and the mounting surface.
3. Place the mounting flange over the LED module. Check that it is ro erly seated on the rubber
gasket and that the gasket and mounting surface form a seal to maximize weather resistance.
4. Align the holes in the gasket and flange and use the self-ta ing screws to secure unit in lace.
Mounting Accessories: (not included)
SL-1311SM: Re lacement lastic mounting flange for SL-1311-MA/B.
SL-1311-MA/B SL-1311-MA/B
Power
Su ly
Black wire
Yellow
wire
White wire
Red wire
Black
wire
Yellow wire
White wire
Red wire
SS-032Q
(O tional SPST
Switch)
White wire
Connect to ower
su ly to set
alternating flash.
See descri tion
below.

ENFORCER
®
High Intensity 1Wx4 Blue LED Module
4 SECO-LARM
®
U.S.A., Inc
Flash Patterns:
1. LEDs are grou ed into two sets, Set 1 and Set 2.
The left air of LEDs are Set 1; right air of LEDs are Set 2.
2. To change atterns, momentarily connect the strobe’s yellow wire to +VDC:
Each connection to ower will move to the next attern.
Hint: Use a rogramming switch (not included)—see Wiring and Installation on age 3.
1. After changing, the flash attern will first run one time, ause, then begin re eating.
2. Internal memory will retain last setting when ower is disconnected.
Pattern #
Flash pattern
Pattern #
Flash pattern
1
Single (2Hz)
4
Quad (2Hz)
2
Double (
2Hz
)
5
Randomly
cycles all atterns
3
Tri le (2Hz)
Altern
ate
s
between Set 1 LEDs and Set 2 LEDs
6
Single flash each
set
10
Ra id flash with fast alternation
7
Double flash each
set
11
Ultra
ra id flash with slow alternation
8
4x flash each
set
12
Pattern
6
/
Pattern
8
9
5x flash each
set
13
Pattern
6
/
Patte
rn
10
All LEDs light together
14
Single flash
1
8
Ra id flash
15
Double flash
1
9
Bursts of ultra ra id flash
1
6
4x flash
20
Pattern 1
4
/ Pattern 1
6
1
7
5x flash
21
Pattern 1
4
/ Pattern 1
8
Other
22
Set 1 steady ON; Set 2 double flash
23
All
LEDs steady
ON
Cali ornia Proposition 65 Warning: These roducts may contain chemicals which are known to the State of California
to cause cancer and birth defects or other re roductive harm. For more information, go to www.P65Warnings.ca.gov.
WARRANTY: This SECO-LARM roduct is warranted against defects in material and workmanshi while used in normal
service for a eriod of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is
limited to the re air or re lacement of any defective art if the unit is returned, trans ortation re aid, to SECO-LARM.
This warranty is void if damage is caused by or attributed to acts of God, hysical or electrical misuse or abuse, neglect,
re air, or alteration, im ro er or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines
that such equi ment is not o erating ro erly as a result of causes other than defects in material and workmanshi .
The sole obligation of SECO-LARM, and the urchaser’s exclusive remedy, shall be limited to re lacement or re air only,
at SECO-LARM’s o tion. In no event shall SECO-LARM be liable for any s ecial, collateral, incidental, or consequential
ersonal or ro erty damages of any kind to the urchaser or anyone else.
NOTICE: The information and s ecifications rinted in this manual are current at the time of ublication. However, the
SECO-LARM olicy is one of continual develo ment and im rovement. For this reason, SECO-LARM reserves the right
to change s ecifications without notice. SECO-LARM is also not res onsible for mis rints or ty ogra hical errors.
Co yright © 2021 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be re roduced or co ied, in whole
or in art, without the written ermission of SECO-LARM.
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Website: www.seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
E-mail: [email protected]
MI_SL
-
1311
-
MA
-
B
_210630.docx
PI
TJW2
Table of contents
Other SECO-LARM Control Unit manuals
Popular Control Unit manuals by other brands

Topline
Topline TOP-FLO 77 Series Installation & maintenance manual

AsahiAV
AsahiAV 15 user manual

DoorHan
DoorHan PCB-SH Programming instructions

oventrop
oventrop Regufloor HW Installation and operating instructions for the specialised installer

RF-Star
RF-Star SimpleLink RF-BM-2652P3 manual

Neptune
Neptune WXM Setup guide