1Carefully unpack box and make sure you have all items
shown below.
2Unlock and open front panel
of unit for wiring and setup.
What’s what?
Important components labeled
Resident Directory Back Plate
Plate removes to allow insertion of
user-printed resident directory insert.
Printable templates can be downloaded
from summitcontrol.com/resources.
Ascent Camera
For automatic and on-demand photo capture
Power and Relay Terminals
For wiring to power and gate operator or
door opener. See Page 2.
Antenna Cables
Status and Event Terminals
For wiring to check gate status and for
request-to-exit devices. See Page 3.
Wiegand Device Terminals
For wiring to Wiegand-compatible devices.
See summitcontrol.com/resources.
SIM Card
If you have your own SIM card, see page 4
and follow the instructions entitled,
Installing a Third-Party SIM Card.
Relay Status LEDs
Relay is active when lit
WARNING!
AUTOMATIC GATES CAN CAUSE
SERIOUS INJURY OR DEATH!
ALWAYS CHECK that the GATE PATH
IS CLEAR BEFORE OPERATING!
Reversing or other safety devices
should ALWAYS BE USED!

IMPORTANT!
r
Ascent WILL NOT WORK until the
activation process is COMPLETE!
Follow the Activation Guide or call
Summit Control at (844) 259-8265 to
activate your unit.
Continued on next page...
Please use all four screws when mounting unit to pedestal. Leave “hockey puck” antenna
in place, even if using extensions. Seal any holes or gaps created in unit enclosure.
Failure to follow these instructions can result in damage to the unit!
CAUTION!

QUICK START GUIDE
Ascent Unit Key Carriage Bolt
( x4 )
Hex Nut
( x4 )
12-V AC/DC Adapter
(PS-12DC1)
We recommend mounting Ascent on a
gooseneck pedestal using included hardware.
If using alternate mounting, two (2)
Ascent 10' Cable Extension (p/n 16-X-EXT)
products should be purchased and installed.
Failure to do so may result in NO SIGNAL!
IMPORTANT!
r
Unit shown with front panel fully open.
Internal wiring not shown for clarity.
1 of 4
Model 16-X2
2 of 4
4Close and lock front panel.
Now follow the Activation Guide to create
an account and begin using Ascent.
INSTALLATION COMPLETE!
N
QUICK START GUIDE
© 2018 Security Brands, Inc. All rights reserved.
Before going forward,
double check wiring and
ensure unit has power!
For additional wiring
options, see Page 3.
STOP!

2 20 1
5Make sure gate path is clear, then
key in temporary code 2012 on
keypad and confirm gate opens.
Adding and deleting codes is done through
Summit Control and NOT from the keypad!
RELAY A
J4
RELAY B
J5
12–24 VAC/DC
POWER
J3 J8 J9 J12
DIGITAL INPUTS
3Connect wires
Feed wires through back of
unit and connect as shown.
If you will not be using the 12-V AC/DC adapter,
please go to Page 4 and follow the procedure,
Using a Third-Party Power Source.
Do not exceed 24 VAC/DC! Failure to choose a
compatible power source can damage unit!
CAUTION!

Ascent Power and Relay Terminals
12–24 VAC/DC
POWER
Gate Operator / Door Opener
POS. (+)
NEG. (–)
COM
RADIO
COM
REVERSE LOOP
COM
OPEN
STOP
CLOSE
12-V AC/DC Adapter
(Model PS-12DC1 included)
The GROUND terminal is optional unless
required by local code(s). If using, please
connect to earth ground or equivalent.
OR
Relay B can be wired to a second device
in the same manner.
FREE EXIT
COM
+–
N/C
COM
N/O
N/C
COM
N/O
POS. (+)
NEG. (–)
GND
# 1
GND
# 2
GND
# 3
Third-Party 12–24-VAC/DC
Power Source
Model 16-X2
QSG-16X2-EN Rev. D (6/2018)
If plugging into duplex outlet,
remove screw from outlet plate,
and secure with included screw.
Additional wiring diagrams
can be found on Page 3.
Consult gate operator or
door opener manual for
exact connections.
Terminals vary widely
across manufacturers
and models.
3 of 4
Model 16-X2
QUICK START GUIDE
J7
GATE 1
J13
GATE 2 EVENT
J6
AStatus Check
Wiring to enable Gate Status Check
(if equipped with limit switches)
Open Limit Switch
Close Limit Switch
Optional
wire
splices
N/C
N/C
Gate Operator
BEvent Input
Wiring for accessories such as a request-to-exit device
Ascent Status and
Event Terminals
GND
N/O
COM
N/O
COM
N/O
CLOSE
GND
OPEN
CLOSE
GND
OPEN
J7
GATE 1
J13
GATE 2 EVENT
J6
Ascent Status and Event Terminals
CLOSE
GND
OPEN
CLOSE
GND
OPEN
Request-to-Exit
(S-RTE-P is shown)
GND
N/O
The Status Terminals are designed for
low voltage (3 V or less). Check the
voltage on your status wires before
connecting. If it is above 3 V, you will
need to contact Technical Support.
Exceeding 3 V can damage Ascent!
CAUTION!

4 of 4
3a Connect wires to unit as shown in
Step 3.
3b Connect wires to your power source,
making sure you connect positive to
positive and negative to negative.
CAUTION!

Double check that you’ve wired from
positive on Ascent to positive on your
power source and negative on Ascent to
negative on your power source.
Reverse polarity can damage Ascent!
1Push existing SIM card in until it
unlocks with “click” sound. 2Remove existing SIM card and locate
new SIM card. 3Insert new SIM card until it locks in
place with “click” sound.
Installing a
Third-Party
SIM Card
(Optional)
Using a
Third-Party
Power Source
(Optional)
IMPORTANT!
r
If you would like to use a third-party
power source, such as solar, verify that
it conforms to the following specs:
Input 12–24 VAC/DC
no more than 10% beyond this range
Current Draw less than 190 mA @ 12 VDC
less than 160 mA @ 24 VDC
Model 16-X2
QUICK START GUIDE
© 2018 Security Brands, Inc. All rights reserved.
?NEED HELP Call (844) 259-8265
Email [email protected]
We are available Mon–Fri / 8am–5pm Central
QSG-16X2-EN Rev. D (6/2018)

Other Security Brands IP Access Controllers manuals

Security Brands ASCENT M3 User manual

Security Brands

Security Brands ASCENT M3 User manual

Security Brands ASCENT M8 User manual

Security Brands

Security Brands ASCENT M8 User manual

Security Brands RIDGE RESKEY 14-RK10 User manual

Security Brands

Security Brands RIDGE RESKEY 14-RK10 User manual

Security Brands ASCENT R1 User manual

Security Brands

Security Brands ASCENT R1 User manual

Security Brands Ascent C2 User manual

Security Brands

Security Brands Ascent C2 User manual

Security Brands 16-X1 User manual

Security Brands

Security Brands 16-X1 User manual

Security Brands RECEIVER 300 User manual

Security Brands

Security Brands RECEIVER 300 User manual

Popular IP Access Controllers manuals by other brands

Kaba ILCO RAC 660G XT installation guide

Kaba

Kaba ILCO RAC 660G XT installation guide

Modesto MAK-21 instruction manual

Modesto

Modesto MAK-21 instruction manual

Extel JAZZY 100 instructions

Extel

Extel JAZZY 100 instructions

Roger PR411DR installation guide

Roger

Roger PR411DR installation guide

ZKTeco MA500 Installation guide & user manual

ZKTeco

ZKTeco MA500 Installation guide & user manual

DOM ELS Access Manager V8 Assembly and operating instructions

DOM

DOM ELS Access Manager V8 Assembly and operating instructions

Akuvox A03S manual

Akuvox

Akuvox A03S manual

Roger CEB12 installation manual

Roger

Roger CEB12 installation manual

Hewi ES5403 Installation instruction

Hewi

Hewi ES5403 Installation instruction

Tidomat SO-3393 installation instructions

Tidomat

Tidomat SO-3393 installation instructions

Ness M1KAM quick start guide

Ness

Ness M1KAM quick start guide

Dahua ASR2101H-D user manual

Dahua

Dahua ASR2101H-D user manual

TCS codelock12 Product information

TCS

TCS codelock12 Product information

EVVA AirKey E.A.WL.CUS Assembly manual

EVVA

EVVA AirKey E.A.WL.CUS Assembly manual

SIB TF1 user manual

SIB

SIB TF1 user manual

Citadele DIGIPASS 500 operating instructions

Citadele

Citadele DIGIPASS 500 operating instructions

Alarm Lock Trilogy DL3000 Series Programming instructions

Alarm Lock

Alarm Lock Trilogy DL3000 Series Programming instructions

Inovonics Wander Management Evaluation Kit quick start guide

Inovonics

Inovonics Wander Management Evaluation Kit quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.