Seiler Evolution xR6 User manual

PRECISION MICROSCOPES
EVOLUTION XR6
LED Dental Microscope Slim Model
User’s Manual

2
Table of Contents
Table of Contents 2
Installaon & Assembly 3
LED Illuminaon Instrucons 8
LED Warranty 13
Interpupillary Distance Adjustment 13
Parfocalizing 14
The Color Filter and Cleaning 15
Dimensions 16
Parts Breakdown 17

3
Installaon & Assembly
1. Remove the base from the box and set base
boom up (casters facing up) on the cardboard
or foam from the box for cushion.
2. Remove the base weights from the weights box
and insert the weights one at a me into the
boom of the base.
Align the pins with the holes and depress the
thumb lock buon to put the weights into place.
Flip the base over so that the top center post is
facing upward.
* Be sure to check to make sure that the
weights are secured before ipping the base
over.

4
3. Remove the pole from the packaging and insert pole into the center post hole in the base. Align the two
indenon marks in the pole to the holes in the base center post hole collar.
4. Once the pole is secured into the base, insert the Light Housing/Light Source poron of the microscope
into the top of the pole. This is where the illuminaon system is housed. Make sure that the light source is
secured while inserng the light source into the pole.
Once the pole is in the collar and indenons are
aligned, use the provided Allen Wrench to ghten
the two Allen bolts in the base center post collar to
secure the pole.

5
5. Next insert the Pantographic Arm into the light
source arm.
6. Place the Liquid Light Guide cable through the
boom cover.
7. Aer the Pantographic Arm is inserted and the Liquid Light Guide cable is secure, add the extension piece
into the top of the Pantographic Arm on the under side. Be sure to loosen the black knob and pull plunger on
the Pantographic Arm in order to insert the extension arm. Screw on the white locking knob.
Plunger
8. Next, insert the 45 degree coupler into the extension arm. Screw down the white locking knob.

6
9. Insert the Angle Arm into the 45 degree coupler coming o the opc pod. Screw down the white knob.
10. Insert the Liquid Light Guide cable into the light port opening on the Opcal Pod.
11. Secure the Binocular Head onto the Opcal Pod by ghtening the thumb screw.
Thumb Screw

7
PANTOGRAPHIC ARM BALANCING
NOTE: Pantographic Arm may need tension
adjusted (black knob on top, turn counter-
clockwise to add tension, clockwise to release
tension). This may need to be done if camera/
video are added to the scope. This will increase
or decrease the tension to desired funcon for
user. The Pantographic Arm may have to be in the
horizontal posion to make adjustments.
Tension Knob

8
LED Illuminaon Instrucons
1. INTRODUCTION
Congratulaons on the purchase of your new SSL-2000 Light Source! This user-friendly LED light source is a high
eciency light source ulizing state of-the-art superior illuminaon technology. It oers a variety of features such as:
• 6500º K daylight brightness for good color denion
• Quiet operaon
• Long life, 50,000 hrs.
• Compact and light weight
• Pulse-width Modulaon (PWM) Electrical Dimming
This secon of the manual will help you to install the device and opmally integrate it with other components of
your system. It will also instruct you how to operate the LED Light Source and how to keep it clean. It will give you
maintenance and service guidelines as well as recommendaons for best performance results.
1.1 INDICATIONS FOR USE: The LED Light Source is used to illuminate the site of surgery during minimally invasive
surgical procedures. The light is transmied from the light source through a ber opc cable and a scope.
2. WARNINGS
To prevent re or electric shock, do not open or expose the LED light source unit to rain or moisture. Refer all servicing to
qualied personnel only.
Not suitable for use in presence of ammable anesthec mixture with air or with oxygen or nitrate oxide.
To prevent any potenal electro-magnec interference, do not use any kind of cellular phone near the
light source.
This product should be used only with type BF endoscopic instruments which have been cered
according to IEC 601-1 for medical equipment and IEC 601-2-18 for endoscopic equipment.
Cauon: This product is not provided as sterile.
Cauon: All devices connecng to the LED Light Source must be classied as medical equipment. When
addional informaon processing equipment is connected to the LED Light Source, the operator must
determine that all equipment complies with the appropriate end-product standards (such as IEC 60950
or IEC 60065 and the Standard for Medical System, IEC 60601-1-1).
Cauon: The LED Light source can cause permanent eye damage if viewed directly with unprotected eye.
To reduce the chance of eye damage, set the intensity control always to the minimum level and plug the
ber opc cable into the unit before turning on the power.
EQUIPMENT CONNECTION
Cauon: The ber opc cable must be a NON-CONDUCTIVE CABLE. It should not have conducve
shielding or any other conducve connecon between the paent and equipment. Such connecon will
impair safety of the equipment. It must be rinsed free of soaking/disinfectant soluon and dried before
plugging into the LED light source receptacle. Ensure the opcal surface is clean before engaging into the
light source.

9
3. SPECIFICATIONS
Item Specicaon
Light Source Type LED (Light Eming Diode)
Power 50 Wa
Color Temperature 6500º K
Led life 50,000 hours (typical)
Light guide adapter
Brightness control PWM (Pulse-width Modulaon) – 0-100% Dimming
Input voltage 100-240V AC, 50/60 Hz
Rated Power 52 wa
Regulatory Approvals UL60601-1,CAN/CSA C22.2 No.601.1 (SUP1+AM2),EN 60601-1-2 and CE
marked
Equipment Class Class I, BF-type
Mode of Operaon Connuous operaon
Water Resistant Not Protected Equipment, IPX0
Operang Environment
Temperature
Relave Humidity
Air Pressure
+0° to +40° C (32° to 104° F)
0 to 85%rh, non condensing
700 to 1060 hPa
Storage Environment
Temperature
Relave Humidity
Air Pressure
-20° to +60° C (-4° to 140° F)
30 to 95%rh, non condensing
700 to 1060 hPa
Dimensions 4.65” W x 3.32” H x 7.25” D
Weight 2.5 lbs./1.14 kg
4. OPERATING ELEMENTS, SYMBOLS AND FUNCTIONS
4.1 FRONT PANEL
No. Name Funcon
1Power switch Turns the light source on and o. Fan will operate
2Light Guide Adapter
3Intensity Control Electronically controls the light output
2
1
3

10
4.2 REAR PANEL
Figure 2. LED Light Source Rear Panel
No. Name Funcon
1AC main inlet Accepts AC power cord
2Fuse 2A, 250V (1/4” x 1 ¼”) me delay
3Grounding Connector For potenal equalizaon
4Venng grids Allows adequate venlaon and cooling of the light
source
4.3 Boom Panel
Figure 3. LED Light Source Product Label
2
3
14

11
5. INSTALLATION
5.1 SETTING UP THE LED LIGHT SOURCE
Place the LED light source on a stable surface (cart, counter, stand, etc.).
NOTE: Avoid places where the light source may be splashed with liquid.
Absolutely DO NOT use in any environment with explosive or ammable gases.
DO NOT block the venng grids of the LED light source.
Make sure the power switch is in OFF posion.
Connect AC power cord to the power inlet located on the rear panel of the light source.
CAUTION: Use only cords provided with the light source.
Plug the AC power cord into a wall outlet using the three-prong plug supplied with the unit.
CAUTION: To prevent electric shock, connect power cords of peripheral equipment through medical isolaon
transformers.
NOTE: When using medical isolaon transformer, be sure to check the transformer power rangs.
Make sure that the power cord is connected to the main power with three-prong plug (USA use UL2601-1 rated
isolaon transformers and/or power strips only).
CAUTION: When used in clinical or residenal areas near radio or TV units, this equipment may be subjected to radio
interference. To avoid adverse electromagnec eects, DO NOT operate this equipment near RF energy equipment.
5.2 CONNECTING THE FIBER OPTIC CABLE
Turn intensity control to the minimum seng. Connect the light cable to the instrument and then plug the light cable
endng into the port on the front panel.
6. OPERATION
6.1 POWERING UP THE LED LIGHT SOURCE
To operate the LED light source: Turn on the power switch. The indicator on power switch will light.
6.2 LIGHT BRIGHTNESS DISPLAY AND CONTROL
The light brightness adjustment enables the user to obtain a brighter or darker illuminaon of the object of observaon.
Adjust the light intensity by turning the intensity control knob.
7. CLEANING
NOTE: Always disconnect the power cord before cleaning the system.
The unit can be cleaned with any cleaning agent, which is used for external cleaning of electric equipment, according to
instrucons given by the manufacturer of the cleaning soluon.
Do not allow excessive moisture or liquids to come in direct contact with the unit.
Do not use cleaning agents that are not permied for use with plascs, i.e., ammonia, acetone, salty acids (HCl), etc.
Do not allow cleaning agents or liquids to enter the unit outlets.
8. DISINFECTION
8.1 DISINFECTING THE UNIT
NOTE: Always disconnect the power cord before cleaning the system.
Use any disinfectant agents which are commonly applied while disinfecng surfaces of electric medical equipment. Such

12
disinfectant agents are usually in the form of sprays or damp cloths.
Follow the instrucons given by the manufacturer of the disinfectant soluon.
9. SERVICING AND REPAIR
Defecve items of equipment are to be serviced and repaired exclusively by persons authorized by the manufacturer. All
repair work shall employ original manufacturer’s parts only.
9.1 FUSE REPLACEMENT
CAUTION: Always disconnect power cord and turn main switch o before fuse replacement.
Turn light source o and unplug power cord. On back of unit remove fuse by turning fuse cover and pulling out fuse.
Replace fuse with 2 AMP (1/4” x 1 ¼”) me delay 250V rated fuse. Insert back into fuse housing.
Re-connect the power cord and turn the LED light source on according to secon 6.1.
9.2 LIMITED WARRANTY
Your LED light source carries a 1-year warranty from the date of shipment on workmanship and all defects of materi-
al, excluding replaceable sweatbands, headband, beropc cable and lamps. Should your product prove to have such
defects within one year of the shipment. Seiler Instrument will repair or replace the product or component part without
charge. Should your LED Light Source product(s) need servicing under this warranty, please contact, Seiler Instrument
return authorizaon documentaon. You should carefully pack unit in a sturdy carton and ship it to the factory. Please
include a note describing the defects, your name, telephone number and a return address. Warranty does not cover
equipment subject to misuse, accidental damage, normal wear and tear or if transferred to a new owner without autho-
rizaon from Seiler Instrument. This warranty gives you specic legal rights and you may also have other rights that vary
from state to state.
POST WARRANTY REPAIRS: You may return your product(s) for repair, shipping prepaid to the factory. Your product will
be inspected and an esmate of repair charges will be submied to you for approval. Payment must be received before
repairs are completed.
• In the US: 800-489-2282 (toll free)
• FAX number: 314-968-3601
• Customer Service: 314-218-6336
10. END OF PRODUCT LIFE
We encourage our customers to recycle this product whenever possible. Disposal of this unit must be performed in ac-
cordance with the applicable local environmental regulaons.
In the United States a list of recyclers in your area can be found at: hp:/www.eiae.org/.
Please contact customer service to issue a return authorizaon to return product to manufacturer at the end of product
life.
11. TROUBLESHOOTING
Problem Soluon
The power indicator (refer to
4.1) is not lit.
A. Check that the AC power cord is properly connected.
B. Check the unit fuses. If necessary, replace.
The power indicator is lit, but
the lamp will not ignite.
Turn intensity control know clockwise to increase light output intensity.

13
Limited Guarantee / Warranty
Seiler Instrument warrants this product to be free from defect in material and workmanship for a period of 12
months following original purchase. The warranty excludes lamps, lamp sockets, and any other items that
have been misused, neglected, damaged, altered, or used in any manner inconsistent with the instrucons in
this manual.
Seiler Instrument’s obligaons under this warranty are limited to the repair, replacement, or reimbursement of
the product only, and, in no event, is Seiler Instrument liable for any consequenal or special damages, or costs
related to the transportaon, installaon, or any other costs related to a warranted product.
LED Warranty
Interpupillary Distance Adjustment
Looking through the eyepieces on the binocular head, adjust the Interpupillary distance as shown in the image
below, unl the end user is the Field of View in one single image.
0-220º BINOCULAR MICROSCOPE HEAD STRAIGHT/FIXED INCLINE BINOCULAR
MICROSCOPE HEAD

14
eyepiece f 135 f170 f 135 f170 f 135 f170 f 135 f170 f 135 f170 f 135 f170 f 135 f170 f 135 f170 f 135 f170 f 135 f170
1 ( 0.4x ) 3.08 3.88 58.44 46.39 2.70 3.40 66.67 52.94 2.16 2.72 83.33 66.18 1.80 2.27 100.00 79.41 1.35 1.70 133.50 105.88
2 ( 0.6x ) 4.62 5.82 39.00 31.00 4.05 5.10 44.45 35.30 3.24 4.08 55.55 44.10 2.70 3.40 66.70 53.00 2.02 2.55 89.10 70.60
3 ( 0.78x ) 6.01 7.57 29.95 23.79 5.27 6.63 34.19 27.15 4.21 5.30 42.75 33.96 3.51 4.42 51.28 40.80 2.63 3.32 68.44 54.30
4 ( 1.28x ) 9.86 12.42 18.26 14.50 8.64 10.88 20.83 16.54 6.91 8.70 26.05 20.69 5.76 7.25 31.25 24.83 4.31 5.44 41.76 33.09
5 ( 1.6x ) 12.32 15.52 14.60 11.60 10.80 13.60 16.66 13.25 8.64 10.88 20.85 16.70 7.20 9.06 25.00 19.90 5.40 6.80 33.40 26.50
6 ( 2.5x ) 19.25 24.25 9.35 7.42 16.88 21.25 10.67 8.47 13.50 17.00 13.33 10.59 11.25 14.17 16.00 12.70 8.42 10.63 21.38 16.94
1 ( 0.4x ) 3.85 4.85 58.44 46.39 3.37 4.25 66.70 52.95 2.70 3.40 83.33 66.18 2.25 2.83 100.00 79.50 1.69 2.13 133.50 105.60
2 ( 0.6x ) 5.78 7.28 39.00 31.00 5.06 6.38 44.45 35.30 4.05 5.10 55.55 44.10 3.38 4.25 66.70 53.00 2.53 3.20 90.00 70.50
3 ( 0.78x ) 7.51 9.46 29.96 23.79 6.58 8.29 34.20 24.14 5.27 6.63 42.70 33.95 4.39 5.53 51.25 40.72 3.29 4.16 68.40 54.09
4 ( 1.28x ) 12.33 15.52 18.25 14.50 10.79 13.61 20.85 16.53 8.64 10.88 26.05 20.68 7.21 9.07 31.20 24.82 5.40 6.83 41.70 32.96
5 ( 1.6x ) 15.40 19.40 14.60 11.60 13.50 17.00 16.66 13.25 10.80 13.60 20.85 16.55 9.00 11.32 25.00 19.90 6.74 8.50 33.40 26.50
6 ( 2.5x ) 24.06 30.31 9.35 7.42 21.08 26.58 10.67 8.47 16.88 21.25 13.33 10.59 14.08 17.71 15.98 12.70 10.54 13.33 21.35 16.88
1 ( 0.4x ) 4.93 6.21 51.95 41.24 4.32 5.44 59.26 47.06 3.47 4.35 73.80 58.90 2.88 3.62 88.89 70.72 2.16 2.73 118.60 93.77
2 ( 0.6x ) 7.40 9.31 34.65 27.50 6.48 8.16 39.50 31.40 5.20 6.52 49.40 39.20 4.32 5.43 59.25 47.15 3.24 4.10 79.00 62.75
3 ( 0.78x ) 9.62 12.11 26.62 21.15 8.42 10.61 30.40 24.13 6.76 8.48 37.87 30.20 5.62 7.06 45.58 36.27 4.21 5.33 60.80 48.03
4 ( 1.28x ) 15.78 19.87 16.23 12.88 13.82 14.41 18.52 14.71 11.09 13.91 23.08 18.40 9.22 11.58 27.78 22.10 6.91 8.75 37.10 29.27
5 ( 1.6x ) 19.70 24.83 13.00 10.30 17.28 21.76 14.80 11.75 13.82 17.40 18.55 14.70 11.52 14.50 22.25 17.70 8.63 10.90 29.70 23.50
6 ( 2.5x ) 30.80 38.80 8.31 6.60 27.00 34.00 9.48 7.53 21.67 27.17 11.82 9.42 18.00 22.63 14.22 11.31 13.50 17.08 17.00 14.99
1 ( 0.4x ) 6.16 7.76 38.96 30.93 5.40 6.80 44.44 35.29 4.32 5.44 55.56 44.12 3.60 4.53 66.67 52.98 2.69 3.40 89.25 70.59
2 ( 0.6x ) 9.24 11.64 26.00 20.65 8.10 10.20 29.60 23.50 6.48 8.16 37.05 29.45 5.40 6.80 44.45 35.35 4.04 5.10 59.40 47.05
3 ( 0.78x ) 12.02 15.13 19.97 15.86 10.53 13.26 22.79 18.10 8.42 10.61 28.50 22.62 7.02 8.85 34.19 27.15 5.25 6.63 45.71 36.20
4 ( 1.28x ) 19.72 24.83 12.17 9.67 17.28 21.76 13.89 11.03 13.82 17.41 17.37 13.80 11.52 14.51 20.83 16.54 8.62 10.88 27.85 22.06
5 ( 1.6x ) 24.64 31.04 9.75 7.70 21.60 27.20 11.10 8.80 17.28 21.76 13.90 11.05 14.40 18.10 16.70 13.25 10.80 13.60 22.30 17.65
6 ( 2.5x ) 38.50 48.50 6.23 4.95 33.75 42.50 7.11 5.65 27.00 34.00 8.99 7.06 22.50 28.33 10.67 8.47 16.83 21.25 14.26 11.30
illuminated field
59
68
85
101
136
20x/12mm
16x/16mm
magnification
field
magnification
300
400
field
250
magnification
field
OBJECTIVE LENS
10x/18mm
12.5x/18mm
position of
button
magnification
field
175
200
magnification
field
Evoluon xR6 Magnicaon Chart
STEPS:
Set both eyepieces at 0
Take a piece of paper and draw an “X” on it. Place that piece of paper onto a at area at the recommended focal
length (10” with 250mm, 12” with 300mm objecve). Adjust the eyepiece unl you get a single solid image.
Set the scope to the highest power and posion the scope to where the “X” is as sharp as possible.
Then go to the lowest power without moving the microscope’s physical posion and one eye at a me focus the
eyepieces.
Look through the scope and focus on the “X” and change the magnicaon levels to make sure each seng stays
in focus. If the scope goes out of focus start the process over again.
Once the image is clear in both eyes, this completes the Parfocalizing Process.
Parfocalizing

15
There is a lever installed on the side of the microscope body to put in front of the lamp luminous ux an
orange and green lter.
Cleaning
The objecve, placed in front of the eld under clinical or surgical treatment, is exposed to blood and topical
medicine spots, etc. The spots dim the passage of the light, with loss of brightness in the opcal observaon.
Alcohol or ether applied with a clean coon swab can be used to remove all smudges. Use a so CIRCULAR
movement. Use your laboratory’s prescribe procedures to remove blood stains or other contaminants from
your equipment.
If the objecve is blotched too much, change the coon swab in each circular fricon, avoiding spreading
again the impuries.
The Objecve lens can be protected by use of an objecve protector (6132000). It is placed under pressure
in the external margin of the objecve lens and protects it against eventual blows of the surgical tools and
against contaminaon.
The metallic parts (chrome-plated or painted) are cleaned with coon, alcohol and ether.
Lubricaon
Aer some years of use we recommend lubricaon of the “dovetail”, the sliding orthogonal rules for X-Y
translaon. Apply here, with a coon swab a delicate oil lm.
Do not exaggerate the lubricaon. It is self-defeang, and if the microscope is operated inclined to the front,
for sure the oil excess will come out through the front.
For lubricaon use light lm of mineral oil.
Filter Lever
The Color Filter and Cleaning

16
Evoluon xR6
Floor Dimensions
Base Length
27.5 (700mm)
Base Width:
25” (635mm)
Caster:
4” (101.6mm)
Depth:
11.8” (300mm)
Height oor to
light housing;
52”
Height: 70”
Extension Arm:
6” (150mm)
Length of Pantographic
Arm: 26” (660mm)
Angle Arm:
14” (355.6mm)
Max Length:
62” (1574.8mm)
Dimensions

17
Parts Breakdown
Handles
Magnicaon Turret
Binocular Head
LED Illuminaon System
45 Degree
Pantographic Arm
Locking Knob
Fine Focus Knob
Objecve Lens
Tension Knob
Green/Orange Filter

18
General Specic Details
Evoluon xR6
Vercal Opcal Working Distance Minimum Possible 175 mm 6.89 in
Maximum Possible 400 mm 15.75 in
Microfocus vercal adjustment range: 13mm
* Microscope Weight (Floor Model): 237 lbs 108 kg
*Including Packaging (3 boxes)
Electrical Details
Power Supply 90 – 264VAC – automac selecon Power supply
Axillary Power Jack 12vDC – 2.1mm female connector – 500ma Rang
Fuses: 3amp – 5x20mm Cylindrical Slo-Blo – 250VAC
Illuminaon Bulb: LED
Opcal Details
Standard Setup Oponal Setup
Objecve Lens ƒ = 250mm 175 – 400 mm
Eyepieces 10x 12.5x, 26x, 20x
Diopter Seng -6 to +6 NA
Field of Vision 9 - 72 mm * 4.95 - 105.88 mm
Opcal Details
Evoluon xR6 2.3x, 3.2x, 5x, 8.2x, 12.8x, 19x ** Max low: 1.70x – Max High: 48.50x
* Depends on Eyepieces and Objecve Lens
** Max low refers to the lowest power able to be achieved by combinaon of eyepiece and objecve lens
magnicaon. Max High is the maximum power able to be achieved through combinaon of eyepiece
and objecve lens magnicaon.

19
Model Number _______________________________________________________
Serial Number ________________________________________________________
Date Purchased _______________________________________________________
Locaon Purchased ____________________________________________________
Owner’s Record
Notes

We are here to serve you!
If you have any quesons regarding Seiler’s products or services, please feel free to contact us.
Toll-Free: 800.489.2282
Local: 314.968.2282
Fax: 314.968.3601
E-mail: [email protected]
www.seilerinst.com
Dane Carlson - Microscope Division Manager
[email protected]om or ext. 365
Nicole Bas - Corporate Markeng/Sales Representave
[email protected] or ext. 345
Tony Leise - Technical Support, Product Informaon
[email protected] or ext. 363
Sandy Jeremich- Oce Administrator Logiscs
sjeremich@seilerinst.com or ext. 336
Amanda Moroney- Corporate Sales, Event Coordinator, Customer Service
amorone[email protected] or ext. 344
PRECISION MICROSCOPES
PRECISION MICROSCOPES
3433 Tree Court Industrial Blvd.
St. Louis, Missouri 63122
Toll Free: (800) 489-2282
Local: (314) 968-2282
Email: micro@seilerinst.com
Web: www.seilerinst.com
Version 03/2015
Other manuals for Evolution xR6
1
Table of contents
Other Seiler Microscope manuals
Popular Microscope manuals by other brands

3B SCIENTIFIC PHYSICS
3B SCIENTIFIC PHYSICS 400 1003276 instruction manual

Home Science Tools
Home Science Tools MI-5000STD instruction manual

Edu Science
Edu Science M1280X manual

Home Science Tools
Home Science Tools MI-4100STD instruction manual

Vanguard
Vanguard 1210CM, 1211CM, 1220CM, 1221CM, 1222CM, 1223CM, 1230CM, 1231CM, 1232CM,... Operation manual

Labomed
Labomed Prima OPH user manual