SelectBlinds MOTION CM-01 User manual

Happy programming
Favorite position
MOTION CM-01/02 LI-ION TUBULAR MOTOR
Pull Control
Operate with
pull control
Li-ion Battery
Integrated
lithium-ion battery
Motor features
Control options
Support
USB Rechargeable
Rechargeable with
micro USB
Wireless
Cable free
installation
Happy Programming
Dummy proof
programming using
pull control
Favourite Position
Preset a favourite
position
Video
How to install,
program and operate
rtube.nl/red983
CM-01/02
Tube motor
Li-ion battery powered tube motors
with pull operation

English
Conforms to
UL Std. 325
Certified to
CSA Std. C22.2#247
MOTION CM-01/02 LI-ION TUBULAR MOTOR
English
WARNING
Read the instructions carefully
before assembling and
using the product. Assembly
can be completed by non-
professionals. For indoor use
only.
Young children can strangle
themselves with the loop
of pull cords, chains and
tapes, and cords that operate
window coverings.
To avoid strangulation and
entanglement, keep cords out
of reach of young children.
Cords may ensnare a child’s
neck.
Move beds, cots and furniture
away from window covering
cords.
Do not tie cords together.
Make sure cords do not twist
together and form a loop.
Cleaning
Follow these general rules when cleaning the
outside of the device and its components:
Use a damp, soft, lint-free cloth. Avoid getting
moisture in openings.
Do not use aerosol sprays, solvents, alcohol,
or abrasives.
Service & Support
Do not perform repairs yourself. Do not attempt
to open the device or disassemble it. You run
the risk of electric shock and voiding the limited
warranty. No user-serviceable parts are inside.
Warranty Service
First follow the advice in this manual. If the
product appears to be damaged or does not
function properly, go to your local dealer for
instructions on how to obtain warranty service.
English

MOTION CM-01/02 LI-ION TUBULAR MOTOR
Important Safety instructions
WARNING: To reduce the risk of severe injury or
death, it is important to follow these instructions for
personal safety. Save these instructions.
Read and follow all installation instructions.
This appliance can be used by children aged
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack
of experience and knowledge if they have been
given supervision or instruction concerning use of
the appliance in a safe way and understand the
hazards involved. Children should not play with
the appliance. Cleaning and user maintenance
should not be performed by unsupervised
children.
Do not allow children to play with fixed controls.
Keep remote controls away from children.
Frequently examine the installation for imbalance
and signs of wear or damage to cables and
springs. Do not use if repair or adjustment is
necessary.
This instruction manual is also available on the
website.
The drive shall be disconnected from its power
source during cleaning, maintenance and when
replacing parts.
The A-weighted emission sound pressure level of
the drive is equal to or less than 70dB(A).
Indoor and household use only.
Disconnect the drive from the supply or switch off
the automatic controls when maintenance, such
as window cleaning, is being carried out in the
vicinity.
When operating a biased switch, make sure that
other persons are kept away.
Do not operate when maintenance, such as
window cleaning, is being carried out in the vicinity.
The tube motor must only be supplied with safety
extra low voltage corresponding to the marking on
the appliance.
This appliance contains batteries that are non-
replaceable.
Important Installation instructions
WARNING: Important safety instructions. Follow all
instructions, since incorrect installation can lead to
severe injury.
This motor can only be used with soft material for
driven parts.
Hazardous unprotected moving parts of the drive
must be installed higher than 2.0m above the
floor or any other level surface that could provide
access to it.
Install the actuating member of a manual release
at a height less than 1.8m.
The actuating member of a biased switch is to be
located within direct sight of the driven part but
away from moving parts. It is to be installed at a
minimum height of 1.5m and not accessible to the
public.
The mass and the dimension of the driven part
must be compatible with the rated torque and
rated operating time.
Fixed controls have to be clearly visible after
installation.
The driven part must be compatible with the rated
torque (0.2N.m/0.65N.m) and rated operating
time (12min).
Minimum tube diameter: Ø25mm.
The drive is intended to be installed at a height
of at least 2.0m above the floor or any other
accessible level surface.
All-pole disconnection switches must be
incorporated in the fixed wiring in accordance with
the wiring rules.

Click!
Click!
Click!
1
2
3
4
5
MOTION CM-01/02 LI-ION TUBULAR MOTOR
Charge before first use. (See step 17)
A green LED will flash.
The motor can be used during charging.
Installing the blind
Charge to activate the motor

8
6
7
MOTION CM-01/02 LI-ION TUBULAR MOTOR
Pull and hold the chain until the blind has
reached the bottom limit.
If the blind moves in the opposite direction,
release the chain and pull and hold again.
Adjust until the desired bottom limit
has been reached.
Save the position by pushing the button
until the blind moves up and down.
Pull and hold the chain until the blind has reached
the upper limit. If the blind moves in the opposite
direction, release the chain and pull and hold again.
Adjust until the desired
upper limit has been
reached
English
Set upper limit
Set bottom limit

9
10
11
MOTION CM-01/02 LI-ION TUBULAR MOTOR
Save the position by pushing the button until
the blind moves up and down.
Pull the chain shortly to start or stop the blind.
Pull the chain shortly to
start or stop the blind.
Operating the blind
Optional: set favourite position

12
13
14
MOTION CM-01/02 LI-ION TUBULAR MOTOR
Pull and hold the chain for approximately
7 seconds until the blind moves up and down.
Go to any position other than the saved
favourite position.
Hold the chain for 5 seconds
The blind moves to the favourite position.
English
Move to favourite position

16
15
MOTION CM-01/02 LI-ION TUBULAR MOTOR
The favourite position can only be deleted when
the blind is placed in the favourite position.
Hold the button for approximately 10 seconds.
After 5 seconds, the blind will move up and
down. Keep pushing the button until the blind
moves up and down again.
Repeat steps 6 - 9 to save new end limits.
Pull and hold the chain for approximately
7 seconds untill the blind moves up and down.
Go to step 11 to program a new favourite
position.
Delete end limits
Delete favourite position

17
18
18.1
MOTION CM-01/02 LI-ION TUBULAR MOTOR
Blinking red during
operation;
Charge the battery
Blinking green;
battery is charging
Continuously green;
battery is fully charged
English
Recharge battery
+or
Activate / deactivate the motor
Hold the program button and pull twice to activate or deactivate the motor.
The motor can also be activated by charging it with a micro USB cable.
To prevent the blind from getting damaged, the motor has a transport
mode that makes sure the blind will not be activated before installation.

MOTION CM-01/02 LI-ION TUBULAR MOTOR
Frequently Asked Questions
Problem Cause Solution
Motor is not responding.
Motor is in transport mode. Activate the motor. See step 18.
Motor battery is empty. Charge the motor. See step 17.
Motor LED flashes red. The battery of the motor is empty. Charge the motor. See step 17.
Motor is not charging. Charger is not plugged in or does
not work.
Try a different charger or make sure the
charger is plugged into the outlet.
Blind lowers too far. End limits are programmed
incorrectly. Reprogram end limits. See step 6 - 9.
Unable to program end
limits.
End limits have already been
programmed.
Reset the motor and reprogram end limits.
See step 16 and step 6-9.

CM-03
Li-ion battery powered tube motors
with pull and remote operation
MANUAL CM-03/05

Pull Control
Operate with
pull control
Li-ion Battery
Integrated
lithium-ion battery
Motor features
Control options
Support
Remote Control
Operate with a
remote control
USB Rechargeable
Rechargeable with
micro USB
App Control
Operate with the
MOTION app
Wireless
Cable free
installation
Connectivity
Compatible with
home and building
automation
Speed Control
Consistent
rolling speed
Bi-directional
Two-way
communication for
real-time response
Video
How to install,
program and operate
rtube.nl/red980
App Store
Download the
MOTION app
rtube.nl/red981
Google Play
Download the
MOTION app
rtube.nl/red982
CM-03/05
Li-ion battery powered tube motors with
pull and remote operation
MOTION CM-03/05 LI-ION TUBULAR MOTOR

Conforms to
UL Std. 325
Certified to
CSA Std. C22.2#247
English
WARNING
Read the instructions carefully
before assembling and
using the product. Assembly
can be completed by non-
professionals. For indoor use
only.
Young children can strangle
themselves with the loop
of pull cords, chains and
tapes, and cords that operate
window coverings.
To avoid strangulation and
entanglement, keep cords out
of reach of young children.
Cords may ensnare a child’s
neck.
Move beds, cots and furniture
away from window covering
cords.
Do not tie cords together.
Make sure cords do not twist
together and form a loop.
Cleaning
Follow these general rules when cleaning the
outside of the device and its components:
Use a damp, soft, lint-free cloth. Avoid getting
moisture in openings.
Do not use aerosol sprays, solvents, alcohol,
or abrasives.
Service & Support
Do not perform repairs yourself. Do not attempt
to open the device or disassemble it. You run
the risk of electric shock and voiding the limited
warranty. No user-serviceable parts are inside.
MOTION CM-03/05 LI-ION TUBULAR MOTOR

Important Safety instructions
WARNING: To reduce the risk of severe injury or
death, it is important to follow these instructions for
personal safety. Save these instructions.
Read and follow all installation instructions.
This appliance can be used by children aged
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack
of experience and knowledge if they have been
given supervision or instruction concerning use of
the appliance in a safe way and understand the
hazards involved. Children should not play with
the appliance. Cleaning and user maintenance
should not be performed by children without
supervision.
Do not allow children to play with fixed controls.
Keep remote controls away from children.
Frequently examine the installation for imbalance
and signs of wear or damage to cables and
springs. Do not use if repair or adjustment is
necessary.
This instruction manual is also available on the
website.
The drive must be disconnected from its power
source during cleaning, maintenance and when
replacing parts.
The A-weighted emission sound pressure level of
the drive is equal to or less than 70dB(A).
Indoor and household use only.
Disconnect the drive from the power supply
or switch off the automatic controls when
maintenance, such as window cleaning, is being
carried out in the vicinity.
When operating a biased switch, make sure that
other persons are kept away.
Do not operate when maintenance, such as
window cleaning, is being carried out in the
vicinity.
The tube motor must only be supplied with safety
extra low voltage corresponding to the marking on
the appliance.
This appliance contains batteries that are non-
replaceable.
Important Installation instructions
WARNING: Important safety instructions. Follow all
instructions, since incorrect installation can lead to
severe injury.
This motor can only be used with soft material for
driven parts.
Hazardous unprotected moving parts of the drive
must be installed higher than 2.5m above the
floor or any other level surface that could provide
access to it.
Install the actuating member of a manual release
at a height less than 1.8m.
The actuating member of a biased switch is to be
located within direct sight of the driven part but
away from moving parts. It is to be installed at a
minimum height of 1.5m and not accessible to
the public.
The mass and the dimension of the driven part
must be compatible with the rated torque and
rated operating time.
Fixed controls have to be clearly visible after
installation.
The driven part must be compatible with the rated
torque (1.1N.m/2.2N.m) and rated operating time
(12min).
Minimum tube diameter: Ø25mm.
The drive is intended to be installed at a height
of at least 2.5m above the floor or any other
accessible level surface.
All-pole disconnection switches must be
incorporated in the fixed wiring in accordance with
the wiring rules.
MOTION CM-03/05 LI-ION TUBULAR MOTOR

FCC Manual
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference,
and
(2) this device must accept any interference received,
including interference that may cause undesired
operation.
FCC ID: ZY4CM03
FCC ID: ZY4CM05
Regulatory Information
1 FCC Information for User
This product does not contain any user
serviceable components and is to be used with
approved antennas only. Any product changes or
modifications will invalidate all applicable regulatory
certifications and approvals.
2 FCC Electronic Emission Notices
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received,
including interference that may cause undesired
operation.
3 FCC Radio Frequency Interference
statement
This equipment has been tested and found to
comply with the limits for a class B digital device,
pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection
against harmful interference when the equipment is
operated in a commercial environment. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications.
Operation of this equipment in a residential area
may cause harmful interference, in which case the
user will be required to correct the interference at
their own expense.
If this equipment does cause harmful interference
to radio or television reception, which can be
determined by turning the equipment off and on, the
user is encouraged to try to correct the
interference by one or more of the following
measures:
Reorient or relocate the receiving antenna
Increase the distance separating the equipment
and receiver
Connect the equipment to an outlet on a circuit
different from that to which the receiver is
connected
Consult the dealer or an experienced radio/TV
technician for help
EnglishEnglish
MOTION CM-03/05 LI-ION TUBULAR MOTOR

Channels Wall
mount
Program
blinds
Single
select
Channel
select
Max.
blinds
Max.
scenes
Frequency Range Power supply Length Width Height Certificates
CM-11
Hand-held remote 1■ ■ - - unlimited n/a 433 MHz 30 m with
1 concrete wall CR2430 3.0V 120 mm 45 mm 14 mm
CM-12
Hand-held remote 5■ ■ ■ ■■unlimited n/a 433 MHz 30 m with
1 concrete wall CR2430 3.0V 120 mm 45 mm 14 mm
CM-13
Hand-held remote 15 ■■■■■unlimited n/a 433 MHz 30 m with
1 concrete wall CR2430 3.0V 120 mm 45 mm 14 mm
CM-15
Wall remote 1■ ■ - - unlimited n/a 433 MHz 30 m with
1 concrete wall CR2430 3.0V 66 mm 32,5 mm 13,8 mm
CM-16
Wall remote 4 ■- - - unlimited n/a 433 MHz 30 m with
1 concrete wall 3 x CR2430 3.0V 86 mm 86 mm 17 mm
CM-17
Table remote 4 - ■- - unlimited n/a 433 MHz 30 m with
1 concrete wall 2 x CR2450 3.0V 70,3 mm 62,7 mm 52,3 mm
CM-18
Pull remote 1 - - - - unlimited n/a 433 MHz 20 m open
space 2 x LR44 1.5V 19,5 mm ø 69,9 mm
CM-20
Motion Wi-Fi bridge n/a ■ ■ - - 30 20 433 MHz
Wi-FI 2.4 GHz 30 m with
1 concrete wall Micro USB - 5V DC 100 mm ø 25 mm
MOTION CM-03/05 LI-ION TUBULAR MOTOR

English
Channels Wall
mount
Program
blinds
Single
select
Channel
select
Max.
blinds
Max.
scenes
Frequency Range Power supply Length Width Height Certificates
CM-11
Hand-held remote 1■ ■ - - unlimited n/a 433 MHz 30 m with
1 concrete wall CR2430 3.0V 120 mm 45 mm 14 mm
CM-12
Hand-held remote 5■ ■ ■ ■■unlimited n/a 433 MHz 30 m with
1 concrete wall CR2430 3.0V 120 mm 45 mm 14 mm
CM-13
Hand-held remote 15 ■ ■■■■unlimited n/a 433 MHz 30 m with
1 concrete wall CR2430 3.0V 120 mm 45 mm 14 mm
CM-15
Wall remote 1■ ■ - - unlimited n/a 433 MHz 30 m with
1 concrete wall CR2430 3.0V 66 mm 32,5 mm 13,8 mm
CM-16
Wall remote 4 ■- - - unlimited n/a 433 MHz 30 m with
1 concrete wall 3 x CR2430 3.0V 86 mm 86 mm 17 mm
CM-17
Table remote 4 - ■- - unlimited n/a 433 MHz 30 m with
1 concrete wall 2 x CR2450 3.0V 70,3 mm 62,7 mm 52,3 mm
CM-18
Pull remote 1 - - - - unlimited n/a 433 MHz 20 m open
space 2 x LR44 1.5V 19,5 mm ø 69,9 mm
CM-20
Motion Wi-Fi bridge n/a ■ ■ - - 30 20 433 MHz
Wi-FI 2.4 GHz 30 m with
1 concrete wall Micro USB - 5V DC 100 mm ø 25 mm
MOTION CM-03/05 LI-ION TUBULAR MOTOR

Pair
button
Pair
button
Channel
Selection
Channel
indicator
Up
Down
Centre
(stop/favourite)
Centre
(stop/favourite)
Up
Channel
indicator
Down
Right
Left
CM-11
1 Channel Remote
CM-12
5 Channel Remote
MOTION CM-03/05 LI-ION TUBULAR MOTOR

1
2
3
4
1 3
2 4
Up
Channel
indicator
Right
Down
Previous
Channel
Next
Channel
Centre
(stop/favourite)
Left
Channel 1
Channel 3
Channel 2 Channel 4
Down
Up
Centre
(stop/favourite)
Pair
button
Pair
button
CM-12
5 Channel Remote
CM-13
15 Channel Remote
CM-17
4 Channel Table Remote
English
MOTION CM-03/05 LI-ION TUBULAR MOTOR
This manual suits for next models
1
Table of contents
Other SelectBlinds Engine manuals
Popular Engine manuals by other brands

Applied Motion Products
Applied Motion Products TSM17C Hardware manual

SOMFY
SOMFY Sonesse Ultra 50 instructions

Leroy-Somer
Leroy-Somer VARMECA 20 Parameter-setting manual

Central Machinery
Central Machinery 96500 Assembly and operation instructions

DANA
DANA 4360-96 parts list

Vortec
Vortec 1600 Service manual