SentexSystems CROWN JEWEL User manual

Doc.. 6001145
Doc.. 6001145Doc.. 6001145
Doc.. 6001145
Rev B
Rev BRev B
Rev B
C
CC
CROWN
ROWNROWN
ROWN J
JJ
JEWEL
EWELEWEL
EWEL
TELEPHONE ENTRY SYSTEM
TELEPHONE ENTRY SYSTEMTELEPHONE ENTRY SYSTEM
TELEPHONE ENTRY SYSTEM
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS


Rev B Doc. 6001145 Page 1 of 25
TABLE OF CONTENTS
IMPORTANT NOTICES.................................................................................................. 3
INSTALLATION TIPS ..................................................................................................... 3
PART 1 PULLING CABLES .......................................................................................... 4
A. WIRE INFORMATION................................................................................................................4
B. SINGLE ENTRANCE CABLE REQUIREMENTS.......................................................................4
C. MULTIPLE ENTRANCE CABLE REQUIREMENTS ..................................................................5
PART 2 MOUNTING THE CABINET............................................................................. 6
A. REMOVE THE FRONT PANEL ASSEMBLY..............................................................................6
B. MOUNT THE CABINET..............................................................................................................6
PART 3 WIRINGTHE UNIT............................................................................................ 7
A. MAIN PROCESSOR BOARD CONNECTIONS .........................................................................7
B. BYPASS BOARD CONNECTIONS............................................................................................8
PART 4 INSTALLING ADDITIONAL FEATURES ....................................................... 13
A. AUX OPEN/REQUEST FOR ACCESS ....................................................................................13
B. DOOR POSTION SENSING.....................................................................................................13
C. REMOTE KEYPAD...................................................................................................................14
D. AUTO-CALL SENSOR.............................................................................................................14
PART 5 TESTING AND ADJUSTING THE UNIT ........................................................15
APPENDIX 1 INSTALLATION PROGRAMMING MENU............................................. 20
APPENDIX 2 SYSTEM RESPONSES......................................................................... 21
FCC REQUIREMENTS................................................................................................. 22
DOC REQUIREMENTS ................................................................................................ 23
IMPORTANT: The Sentex Systems. warranty on this unit is conditioned upon Sentex Systems being
paid in full for this equipment. This warranty will not be honored until such payment is received by
Sentex Systems.
Copyright 2000
All Rights Reserved
This document is protected by copyright and may not be copied or adapted without the prior written consent of
Sentex. This document contains information proprietary to Sentex and such information may not be distributed
without prior written consent of Sentex. The software and firmware included in the Sentex Crown Jewel unit as they
relate to this documentation are also protected by copyright and contain information proprietary to Sentex.
Sentex Systems
Chatsworth, CA
Visit us at www.sentexsystems.com

Page 2 of 22 Doc. 6001145 Rev B
Belden and Datalene are registered trademarks of the Belden Corporation.

Rev B Doc. 6001145 Page 3 of 25
IMPORTANT NOTICES
•The Crown Jewel unit contains static sensitive parts. To avoid damage to the static
sensitive parts, ground the unit and yourself while handling the board(s).
•Please follow the instructions in this manual closely. This document covers the specific
actions needed to install the Crown Jewel system. An incorrect installation could end up
causing you and your customer needless hours of aggravation.
•Prevent lightning damage to the unit. Install a Telephone Line Surge Suppresser as
close to the Crown Jewel as possible.
INSTALLATION TIPS
Please read this section carefully before beginning your installation.
The sections that follow contain detailed procedures for each step required to install a Crown Jewel
system. In addition to those specific procedures, the following installation tips will help ensure your
installation is done correctly and efficiently.
1. GROUND THE UNIT. The Crown Jewel contains parts which may be damaged by static
discharge. A proper earth ground connected to the lower left grounding screw shown in Figure 3
will significantly reduce the chances of damage or improper operation. The shielding in the cables
specified for all remote sensors and controls should also be connected to the earth ground at the
Crown Jewel cabinet end of the cable only.
To be effective, the ground connection must be made by running 12 awg copper wire to a good
ground point (e.g., an electrical panel, a metallic cold water pipe that runs into the earth, or a
grounding rod at least 10 feet in length that is driven into the earth) within 12 feet of the unit. Even
if you have a good earth ground, you should try to discharge any static before handling the circuit
boards. WARNING: Damage caused by static discharge is not covered by warranty.
2. PROVIDE POWER FROM A DEDICATED SOURCE. The outlet(s) into which you plug the Sentex
provided transformer or a DC power supply should each be wired to their own circuit breaker. The
optional CCTV must be plugged into a separate outlet. This will reduce line noise introduced into
system power and minimize the risk of having other equipment interrupt unit operation. Each
Crown Jewel unit and any door strikes must have their own individual transformer.
3. DO NOT OVERLOAD THE TERMINAL BLOCKS. The terminal blocks used in the Crown Jewel
are removable and the pins are soldered into the boards. To connect your wires, remove the
"head" from the correct terminals and open the screws. Insert the wire into the correct opening on
the front and tighten the screw until the wire is held snugly. When you have made all connections
for a given "head", plug it back onto the pins designated for that terminal block. Do the same for
the optional CCTV board.
Stranded wire must be between 16 and 24 awg. Solid wire must be between 18 and 24 awg.
This is the total thickness measurement so, if you are putting two wires in, the combined thickness
must fall within this range. NEVER try to insert more than two wires per terminal.
4. ENSURE GOOD CONNECTIONS. A light tug on the wire will tell you if the connection is secure.
When reconnecting unit components, make sure all pins are straight on chips, connectors, and
terminal block heads.
5. READ THE MARKINGS CAREFULLY. The connection points are marked on the boards clearly.
Before making any connections, be sure to read the markings and check it against the
corresponding figure in these instructions so that you understand the connection you are making.
6. TRAIN YOUR CUSTOMER. The Crown Jewel is easy to operate when you take a few minutes to
train the user, but untrained users can cause serious problems for you and for themselves.
SPEND THE TIME NOW to train your customer- it will save you both a lot of trouble later.

Page 4 of 22 Doc. 6001145 Rev B
PART 1 PULLING CABLES
A. WIRE INFORMATION
•Unshielded cable is acceptable for indoor, weather-proof installations.
•Shielded cable is recommended for outdoor unit locations.
•Cable sizes are different for AC and DC power cables running the same distance (see Table 1).
•Separate cable is necessary for the optional CCTV (see Table 2).
Table 1. Power Wire Distance for Crown Jewel
DC POWER
WIRE SIZE DISTANCE AC POWER
WIRE SIZE
18 AWG
30
'
and under
18 AWG
18 AWG 30'-75' 16 AWG
18 AWG 75'-150' 12 AWG
16 AWG 150'-250' 10 AWG
12 AWG 250'-500' -----
Table 2. Power Wire Distance for Optional CCTV
DC POWER
WIRE SIZE DISTANCE AC POWER
WIRE SIZE
18 AWG
30
'
and under
18 AWG
18 AWG 30'-75' 18 AWG
18 AWG 75'-150' 14 AWG
16 AWG 150'-250' 12 AWG
12 AWG 250'-500' 10 AWG
B. SINGLE ENTRANCE CABLE REQUIREMENTS
Figure 1. Single Entrance Cable Runs and Grounds.
The following cables must be run to the main processor board in the Crown Jewel cabinet:
•Main Processor Power: Run a 2-conductor cable from the outlet into which you will plug the
Sentex supplied 12 VAC transformer (or the 12 VDC power supply you provide) to the Crown
Jewel cabinet. See Table 1 above for the wire size required.
•Telephone Signal: Run 2-conductor 18 to 24 awg twisted pair telephone wires (Belden #8741
for unshielded and Belden #9502 for shielded installations or equivalent) from the bypass board
location to: ✓telephone line ✓residence phone jack ✓Crown Jewel cabinet (2 pairs).
Ensure that the wire shields are grounded as shown in Figure 1, above.
•Accessory Control: Run 2 conductor cables from the door strike, magnetic lock, and/or
gate operator to the Crown Jewel cabinet. See device specifications for wire size.

Rev B Doc. 6001145 Page 5 of 25
The following cables must be run to the CCTV board in the Crown Jewel cabinet:
•CCTV Power: Run a 2-conductor cable from the outlet into which you will plug the Sentex
supplied 12 VAC transformer (or the 12 VDC power supply you provide) to the Crown Jewel
cabinet. See Table 2 above for the wire size required.
•Video Monitor Signal: Run a coaxial cable with BNC connectors (Belden #9240 or
equivalent) from the monitor or television to the Crown Jewel cabinet.
Door Strike Power: Run 2 conductor cables from the power supplies to the door strikes.
NOTE: If you are using Maglock, DC powered relays or DC powered door strikes, be sure
to install a suppression diode or Metal Oxide Varistor across the coil (see Part 3 for details).
•Additional Features: Run wiring for additonal features as required (see Part 4): ✗Aux
Open/Request for Access ✗Door Position Sensing ✗Remote Keypad ✗Auto-Call Sensor
C. MULTIPLE ENTRANCE CABLE REQUIREMENTS
Multiple entrance installations are identical to single entrance installations, except that an additional
twisted pair 22 AWG telephone grade cable must be run between each bypass board location.

Page 6 of 22 Doc. 6001145 Rev B
PART 2 MOUNTING THE CABINET
CAUTION
The brass Crown Jewel cabinet is easily scratched. Use care when handling.
Both the surface mount and flush-mount Crown Jewel cabinets are water-resistant, and may be
located either indoors or outdoors. Mount the cabinet as follows:
A. REMOVE THE FRONT PANEL ASSEMBLY
Figure 2. Removing Crown Jewel Front Panel Assembly
NOTES: •The removal procedure for surface mount and flush mount Crown Jewel is identical.
•
••
•The optional CCTV is not shown in figure 2.
1. Using the Sentex-supplied hollow hex tool, unscrew four screws located on the front panel.
2. Carefully remove the front panel/main processor board assembly and place on a soft, clean
surface.
B. MOUNT THE CABINET
Figure 3. Mounting the Crown Jewel Cabinet
NOTE: The mounting procedure for surface mount and flush mount Crown Jewel is identical.
1. Carefully remove the knockout plug from the back or the bottom of the enclosure.
2. Mount the unit on the wall or pedestal securely. Mounting hardware is provided with Sentex's
pedestal mount. Tighten all four screws/bolts.
3. Pull all wires into the cabinet.

Rev B Doc. 6001145 Page 7 of 25
PART 3 WIRING THE UNIT
A. MAIN PROCESSOR BOARD CONNECTIONS
Figure 4. Main Processor Board Connections.
CAUTION
Do not apply power to the unit until all other connections have been made.
Damage to the unit may otherwise result.
1. GROUND THE CABINET in accordance with local code to a good earth/cold water ground
nearby. The chassis ground lug is located on the lower left-hand corner of the Main Processor
Board, as shown in Figure 4.
2. GATE/DOOR CONTROLS: Connect the wires from your gate operator or door strike and door
strike power supply to TB1 as follows:
a. Dry Contact Closures (most gate operators):
Relay 1: connect conductors to "NO1" and "COM1" terminals.
Relay 2: connect conductors to “NO2” and “COM2” terminals.
b. Normally Locked Strikes:
Relay 1: connect one conductor from your strike power supply to "NO1" and one
conductor from the door strike to "COM1", then connect the remaining conductors from the
power source and strike off of the board using a wire nut or butt splice.
Relay 2: connect one conductor from your strike power supply to “NO2” and one
conductor from the door strike to COM2”, then connect the remaining conductors from the
source and strike off of the board using a wire nut or butt splice.
c. Magnetic or Normally Open Strikes:
Relay 1, connect one conductor from your power source to the "NC1" terminal and one
conductor from the door strike to the "COM1" terminal. Then, connect the remaining conductors
from the power source and the strike by tying them together using a wire nut or butt splice.
For relay 2, connect one conductor from your power to the “NC2” terminal and one
conductor from the door strike to the “COM2” terminal. Then, connect the remaining conductors
from the source and the strike by tying them together using a wire nut or butt splice.

Page 8 of 22 Doc. 6001145 Rev B
WARNING!
Magnetic locks and DC powered strikes generate voltage spikes that may damage the Crown Jewel
unit. Sentex strongly recommends installing a IN4001 diode or a Metal Oxide Varistor across
the magnetic lock coil. If the IN4001 diode is used, connect the cathode (the banded end) to the
positive side of the coil and the anode to the negative side of the coil.
3. TELEPHONE LINE: connect two pairs of 18 to 24 AWG twisted pair telephone wires to TB3 on
the main processor board, one wire to each pin. If you are using shielded wire for this
connection, connect the shield for each of the cables to the chassis ground on the main
processor board.
CAUTION
High voltages are present in the power supply area of the main processor board when power is
connected to the Crown Jewel unit. Proceed with caution once power has been connected.
4. POWER: Connect the power cable to TB2 on the main processor board and to the transformer
provided with the unit. The unit can also be powered by a 12 VDC power source, which also is
connected to TB2. Polarity is unimportant for both AC and DC power.
NOTE: The crown jewel will not charge a battery, so a UPS-type power supply must be used if a
battery back-up is desired.
B. OPTIONAL CCTV BOARD
Figure 5. Optional CCTV Unit.
1. Connect a two conductor 10 to 18 AWG cable (Belden Datalene #9501 or equivalent) to TB 1 on
the lower right corner of the CCTV Power Supply Board. See Table 2.
2. Connect coaxial cable with BNC connectors (Belden #9240 or equivalent) to J2, on the middle
bottom of the CCTV Power Supply Board.

Rev B Doc. 6001145 Page 9 of 25
C. BYPASS BOARD CONNECTIONS
The bypass board allows the Crown Jewel to be bypassed so normal telephone operation can be
maintained in the event of a malfunction.
1. Standard Connection
Figure 5. Bypass Board Hookup (Standard).
Figure 6. Bypass Board Connections (Standard).
1. Connect TB3 on the main processor board to the SYSTEM area of the bypass board as shown in
Figures 5 and 6.
2. Connect one set of the 18 to 24 AWG twisted pair telephone wires between the telephone line
and the Bypass Board TELCO area as follows:
a. On the Bypass Board TELCO area, connect the red wire to the tip terminal (marked as "T"),
and the green wire to the ring terminal (marked as "R").
b. Connect the opposite ends of these wires to the incoming telephone line.
3. Connect the other set of twisted pair telephone wires between the home telephone block and the
Bypass Board as follows:
a. On the Bypass Board HOME area, connect the red wire to the tip terminal (marked as
"T") and the green wire to the ring terminal (marked as "R").
b. Connect the opposite end of these wires to the telephone line entering the house.
See Important Notes on following page.

Page 10 of 22 Doc. 6001145 Rev B
IMPORTANT NOTES
•Whenever the Crown Jewel unit is in use, the Bypass switch must be set to the OPERATE
position.
•Should the Crown Jewel be disconnected for any reason, the Bypass switch must be set to
BYPASS in order to maintain telephone service to the residence.
•In multiple unit installations, if you set the unit switches to BYPASS, you must also reset the unit
ID numbers or the unit will malfunction (see Part 5 for information on setting unit ID numbers).
2. Alarm Unit Connections
Figure 7. Bypass Board Hookup (with Alarm).
Figure 8. Bypass Board Connections (with Alarm).
IMPORTANT NOTE
If the Crown Jewel will be used in conjunction with an alarm unit, it is imperative that the
telephone line connect with the alarm unit first. If the units are not connected in this order,
it will cause sporadic problems with both the alarm and the Crown Jewel unit (see Figure 6).
1. Connect TB3 on the main processor board to the SYSTEM area of the bypass board as
shown in Figures 7 and 8.
2. Connect one set of the 18 to 24 AWG twisted pair telephone wires between the incoming
telephone line and the Alarm unit.

Rev B Doc. 6001145 Page 11 of 25
3. Connect one set of the 18 to 24 AWG twisted pair telephone wires between the Alarm unit and
the Bypass Board TELCO area as follows:
A. On the Bypass Board TELCO area, connect the red wire to the tip terminal (marked "T"),
and the green wire to the ring terminal (marked as "R").
B. Connect the opposite ends of these wires to the Alarm unit.
4. Connect the other set of twisted pair telephone wires between the home telephone block and
the Bypass Board as follows:
A. On the Bypass Board HOME area, connect the red wire to the tip terminal (marked "T") and
the green wire to the ring terminal (marked as "R").
B. Connect the opposite end of these wires to the telephone line entering the house.
IMPORTANT NOTES
•Whenever the Crown Jewel unit is in use, the Bypass switch must be set to the OPERATE
position.
•Should the Crown Jewel be disconnected for any reason, the Bypass switch must be set to
BYPASS in order to maintain telephone service to the residence.
•In multiple unit installations, if you set the unit switches to BYPASS, you must also reset the unit
ID numbers or the unit will malfunction (see Part 5 for information on setting unit ID numbers).
3. Multiple Unit Connections
Figure . Bypass Board Connections (Multiple Units).
NOTE: Although reversed polarity will not damage or degrade Crown Jewel operation, some
telephones will not dial if polarity is reversed.
1. Connect the multiple unit installation twisted pair cable between the TELCO area of the first unit
and the HOME area of the second unit.
2. Repeat he same connection between all addtional units of the installation.
3. Connect the last unit between the TELCO area on the bypass board and the incoming
telephone line.
•If multiple Crown Jewel’s (up to 7 can be used in one installation) are to be installed at the
same site, the bypass boards must be installed in series.
See Important Notes on next page.

Page 12 of 22 Doc. 6001145 Rev B
IMPORTANT NOTES
•Whenever the Crown Jewel unit is in use, the Bypass switch must be set to the OPERATE
position.
•Should the Crown Jewel be disconnected for any reason, the Bypass switch must be set to
BYPASS in order to maintain telephone service to the residence.
•In multiple unit installations, if you set the unit switches to BYPASS, you must also reset the unit
ID numbers or the unit will malfunction (see Part 5 for information on setting unit ID numbers).

Rev B Doc. 6001145 Page 13 of 25
PART 4 INSTALLING ADDITIONAL FEATURES
The following features are connected the same for one or for multiple entrances.
A. AUX OPEN/REQUEST FOR ACCESS
Figure 10. TB5 and Earth Ground on the Main Processor Board.
Any device that provides a contact closure (a Knox box or exit button) can be used to activate
the entrance relays as follows:
1. To activate Relay 1, connect the device to terminals EXIT1 and COM of TB5 on the main
processor board (see Figure 10).
2. To activate Relay 2 (if set as a control), connect the device to terminals EXIT2 and COM of TB5
on the main processor board (see Figure 10).
•Shielded cable should be used (such as Belden 8771). The connect the cable shield to the
ground screw on the lower left corner of the main processor board (see Figure 10).
B. DOOR POSTION SENSING
The Crown Jewel can monitor the position of one entrance (if relay 2 is not set as control) and
react to a change in its status. For example, if an entrance is either pried open, or is held open
more than a minute after its relay deactivates, the unit can:
♦Call the residence or other telephone number and report the status of the entrance,
♦And/or close Relay 2 to activate a device such as a light, CCTV camera or siren.
To activate this feature:
1. Install a normally closed switch either in the door frame or on the gate so that the switch is
depressed when the door or gate is closed.
2. Connect one end of the wires to the door switch terminals labeled normally closed (NC) and
common (COM).
3. Connect the other end of these wires to the EXIT2 and COM terminals of TB5 on the main
processor board (see Figure 10)
•Use shielded cable such as Belden 8771. Connect the cable shield to the ground screw on the
lower left corner of the main processor board (see Figure 10).
•For this feature to work, Relay 2 cannot be set as control. To activate this feature, Relay 2
must be set as a shunt, alarm, or CCTV.
•EXIT1 and COM are still available to activate Relay 1.
If the door contact closure is broken, the Crown Jewel will call, report, and activate Relay 2.

Page 14 of 22 Doc. 6001145 Rev B
C. REMOTE KEYPAD
Figure 11. Remote Keypad Wiring.
The Crown Jewel accepts a second, remote keypad for added versatility. Install the remote
keypad as follows:
♦The remote keypad installation requires a shielded 7 conductor, 18 to 24 AWG cable such as
Belden Datalene #9932 or equivalent.
1. Connect one end of the cable to TB4 on the Crown Jewel’s main processor board (see
Figure 11).
2. Connect the opposite end of the cable to area TB1 on the Remote Keypad board.
3. Connect the cable shield to the ground screw on the lower left corner of the main processor
board (see Figure 11).
D. AUTO-CALL SENSOR
Figure 12. Auto-Call Wiring.
The Crown Jewel has a special feature called “Auto-Call” which automatically places a visitor
call to the residence when a driveway sensor (or any device that provides a contact closure) is
activated. Connect a driveway sensor or other device to the Crown Jewel as follows:
♦The Auto-Call installation requires a 2 conductor shielded cable (such as Belden 8771).
1. Connect one end of the cable to the driveway sensor.
2. Connect the other end of the cable to the “AUTOCALL” and “COM” pins on TB5 of the main
processor board (see Figure 12).
3. Connect the cable shield to the ground screw on the lower left corner of the main processor
board (see Figure 12).

Rev B Doc. 6001145 Page 15 of 25
PART 5 TESTING AND ADJUSTING THE UNIT
After all connections have been made to the Crown Jewel unit, power can now be applied.
The "POWER ON" indicator on the lower left of the main processor board should now be lit.
1. Set Relay 1 Activation Time
Figure 13. Relay Test Jumpers on Main Processor Board TB5.
1. On the Crown Jewel front panel keypad, enter "∗∗∗
∗∗∗∗∗∗
∗∗∗" and then the six digit programming access
password. If the password is accepted, the Crown Jewel will respond with a programming
promt consisting of two short beeps.
•The Crown Jewel comes from the factory with the password set to "000000".
•If you change the password during installation, make sure you write the new password down for
the customer's future reference.
•As soon as the customer is comfortable with programming the Crown Jewel, to maintain
security it is recommended that they change the password and write it down for future
reference.
2. At the programming prompt, select programming step 23 and the desired relay activation time
by entering "23", the 1 to 3 digit activation time of between 1 and 250 seconds, and the "#" key.
For example, if you want a relay activation time of 35 seconds, at the programming prompt,
enter "2335#". If the entry is accepted, the Crown Jewel will respond with two short beeps.
3. Exit the programming mode by pressing "00#". If the command is accepted, the Crown Jewel
will respond with three short beeps.
4. On TB5 of the main processor board, place a jumper between the "EXIT1" and "COM"
terminals (see Figure 13).
5. Verify that Relay 1 activates for the correct period of time and that the gate/door opens
properly.
•If the gate/door does not open properly, adjust the relay activation time accordingly and re-test
using steps 2 through 5, above.
2. Set Relay 2 Activation Time
If you are using Relay 2 as a control relay, program the relay activation time as follows:
1. On the Crown Jewel front panel keypad, enter "∗∗∗
∗∗∗∗∗∗
∗∗∗" and then the six digit programming access
password. If the password is accepted, the Crown Jewel will respond with a programming
promt consisting of two short beeps.

Page 16 of 22 Doc. 6001145 Rev B
2. At the programming prompt, select programming step 24 and the desired relay activation time
by entering "24", the 1 to 3 digit activation time of between 1 and 250 seconds, and the "#" key.
For example, if you want a relay activation time of 35 seconds, at the programming prompt,
enter "2435#". If the entry is accepted, the Crown Jewel will respond with two short beeps.
3. Exit the programming mode by pressing "00#". If the command is accepted, the Crown Jewel
will respond with three short beeps.
4. On TB5 of the main processor board, place a jumper between the "EXIT2" and "COM"
terminals (see Figure 13).
5. Verify that Relay 2 activates for the correct period of time and that the gate/door opens
properly.
•If the gate/door does not open properly, adjust the relay activation time accordingly and re-test
using steps 2 through 5, above.
3. Set Multiple Unit Installation Relays
If your installation has multiple units, repeat procedures 1 and 2, above, as required for each unit.
4. Adjust Audio Feedback
Figure 14. Feedback Pot VR2 and Speaker Volume Pot VR1.
Feedback pot VR2 must be set accurately to ensure proper operation of the Crown Jewel.
Set the feedback pot as follows:
♦The factory setting is indicated by a mark on the rim of the pot.
1. On the Crown Jewel front panel keypad, enter "∗∗∗
∗∗∗∗∗∗
∗∗∗" and then the six digit programming access
password. If the password is accepted, the Crown Jewel will respond with a programming
promt consisting of two short beeps.
2. At the programming prompt, select step 30 by entering "30#". If the command is accepted, the
Crown Jewel speaker will emit a tone for about 45 seconds.
3. While the tone is being emitted, adjust feedback pot VR2 on the main processor board (see
Figure 14) until the tone is at its minimum level.
4. Once the tone has been set to its minimum level, press "∗
∗∗
∗" on the keypad to discontinue the
tone.
5. Exit the programming mode by pressing the "00#". If the command is accepted, the Crown
Jewel will respond with three short beeps.

Rev B Doc. 6001145 Page 17 of 25
5. Adjust Audio Volume
Speaker volume pot VR1 may have to be adjusted for proper operation of the Crown Jewel.
Set the speaker volume pot as follows:
♦The factory setting is indicated by a mark on the rim of the pot.
♦To turn the speaker volume up, turn the adjustment pot clockwise.
♦To turn the speaker volume down, turn the adjustment pot counter-clockwise.
1. Place a call to the tenant and ask them to speak.
2. While they are speaking, listen to theCrown Jewel's speaker volume.
3. If the speaker volume is either too loud or too soft, adjust speaker volume pot VR1 on the main
processor board (see Figure 14).
4. When the speaker volume is set to the desired level, end the call.
6. Verify Telephone Connections
Figure 15. Bypass Board Telephone Test Points.
If you have a telephone test set (also known as a "buttset") with a monitor mode, you can test
the connection to the resident's telephone using the following procedure:
1. Make sure the test set is in monitoring mode.
2. Connect the test set clips to the pins marked "TELCO" on the bypass board (see Figure 15).
Make sure a dial tone is emitted from the test set.
3. Connect the test set clips to the pins marked "HOME" on the bypass board (see Figure 15).
Make sure a dial tone is emitted from the test set.
If you do not have access to a telephone test set, test the connection to the resident's
telephone as follows:
1. Have someone make a normal phone call from the resident's telephone to verify it is operating
properly, then hang up the phone.
2. Press the "# " key on the Crown Jewel keypad. The telephone in the residence should ring.
3. Have someone answer the phone and dial a "9". The door/gate control relays should activate.

Page 18 of 22 Doc. 6001145 Rev B
7. Set Unit ID Numbers (Multiple Unit Installations Only)
In a multiple unit installation, each unit must know its unit number and that there are other units
in the chain. If all units are not correctly identified, remote programming and remote gate
operations will not work properly. Set the unit ID numbers as follows:
♦The unit connected to the phone line closest to the residence should be unit number 1.
♦The unit connected to the phone line farthest from the residence and closest to the telephone
company has the highest unit number.
1. On the Crown Jewel front panel keypad, enter "∗∗∗
∗∗∗∗∗∗
∗∗∗" and then the six digit programming access
password. If the password is accepted, the Crown Jewel will respond with a programming
promt consisting of two short beeps.
2. At the programming prompt, select step 38, the position of this unit in the chain, the total
number of units in the chain, and the "#" sign. For example, if the unit you are currently
programming is the first unit in a four unit chain, you will enter "38 + 1 + 4 + #".
3. Repeat steps 1 and 2 at each of the remaining units.
4. After setting the unit ID numbers, verify that each unit was programmed correctly by entering
"37#" on its keypad.
•The number of beeps emitted by each unit should match the number of that unit in the chain.
•If the number of beeps matches the unit number, label that unit with its unit ID number for
future reference.
•If the beep count is the same for 2 or more units, re-enter the correct unit ID numbers for those
units.
8. Hooking Up Optional CCTV
Figure 16. CCTV Power Supply Board J1 Connector.
1. Plug the loose end of the coaxial cable into the monitor or television. NOTE: Maximum length of
coaxial cable should not exceed 100 feet.
2. When the monitor or television is turned on, picture will appear.
•If picture does not appear, check the J1 connection on the CCTV power supply board.
A. Make sure the connector is firmly attached to the power supply board.
B. The connector is keyed and must be attached in the correct direction. From left to right, the wires
should be: yellow (video); blue (ground); and red (power).
C. If the wires are in reverse order, unplug the connector, turn it over, and plug it back in with the
wires in the correct positions.