Sentiotec wave.com4 touch User manual

WAVE.COM4
SOUND&LIGHT
OPERATING INSTRUCTIONS
Con
s
isting of:
coloured lamp and
operating element
sound&light
Edition
06/13
Item no
. 50950031


OPERATING INSTRUCTIONS 23/44
LED-Coloured lamp sound&light
Description LED- Coloured lamp sound&light
Order reference wave.com4 sound&light coloured lamp set
wave.com4 sound&light operating element
for company
Author Florian Aichstill
Version V01
drafted 06.2013
CONTENTS
1.0.0 GENERAL 25
1.1.0
INTRODUCTION 25
2.0.0 MANUFACTURER’S DECLARATION 26
3.0.0 FITTING INSTRUCTIONS 27
3.1.0
DIMENSIONS / FITTING OPERATING ELEMENT + USB DOCK 27
3.2.0
FITTING THE CONTROL ELEMENT 27
3.3.0
FITTING THE COLOURED LAMP 28
3.4.0
CONNECTION DIAGRAM 29
4.0.0 OPERATING INSTRUCTIONS FOR THE END USER 30
4.1.0
GENERAL SAFETY NOTICES 30
4.2.0
OPERATION 31
4.2.1.
FUNCTION DESCRIPTION 31
4.2.2.
OPERATING ELEMENTS 31
4.2.3.
TABLE OF COLOURS 31
4.2.4.
MODES 32
4.3.0
PROGRAMMING FUNCTIONS 33
4.3.1.
PROGRAMMING CYCLE TIME 33
4.3.2
PROGRAMMING COLOUR TRANSITION PERIOD 34
4.3.3
PROGRAMMING COLOURS 34
4.3.2.
MASTER / SLAVE PROGRAMMING 35
4.3.3.
REMOTE START ACTIVATE/ DEACTIVATE 36
5.0.0 CONNECTION OF SEVERAL sound&light COLOURED LAMPS 36
6.0.0 CONNECTION TO THE wave.com4 SAUNA CONTROL 38
7.0.0 FAULTS, CAUSES, SOLUTIONS 39
8.0.0 TECHNICAL DATA 40
8.1.0
OPERATING ELEMENT 40
8.2.0
LED POWER ELEMENT 40
8.3.0
LED COLOURED LAMP 40

OPERATING INSTRUCTIONS 24/44
CONTROLLED BY
abatec group AG
electronic solutions
Oberregauer Straße 48
4844 Regau, Austria
T: +43 (0) 7672-27720-0
F: +43 (0) 7672-27720-401
www.abatec-ag.com

OPERATING INSTRUCTIONS 25/44
1.0.0 GENERAL
1.1.0 INTRODUCTION
Welcome to the user manual for the innovative, high-tech coloured lamp sound&light.
This user manual is designed to help you start up the LED coloured lamp and connect it to the
appropriate parts of the sauna control ”wave.com4“.
You can operate the coloured lamp in 2 connection modes.
a) Single – operating element master - mode
Pure colour led control, no sauna function, can only be operated with one operating element.
Hardware (connected to the bus bar):
one colour operating element and
one or more LED power elements + associated LED coloured lamp
b) Sauna – operating element slave - mode
The colour-led control is integrated into the sauna control and the operating element acts as a
slave here.
Hardware (connected to the bus bar):
Colour operating element
the sauna base section
one or more LED power elements + associated LED coloured lamp

OPERATING INSTRUCTIONS 26/44
2.0.0 MANUFACTURER’S DECLARATION
We
sentiotec GmbH
Oberregauer Straße 48
A-4844 Regau
hereby declare in relation to the product below
wave.com4 sound&light Coloured lamp set AB0210000001
consisting of:
Coloured lamp AB0210000101
Colour operating element AB0211000101
Control element AB0212000101
that it complies with the following directives
Low-Voltage Directive 2006/95/EC
EMC Directive 2004/108/EC
applied harmonised standards:
Standard designation
1 EN 60335-1: A12:06
2 EN 60335-2-53: 03+A1:2007
3 EN 50366:06
sentiotec GmbH
Markus Wörmanseder
CEO
We reserve the right to make technical changes in the interests of progress. This description
has been drafted to the best of our knowledge. Please inform your dealer or us if you find any
errors therein. Many thanks!
sentiotec GmbH for:
Please note: The distribution of the colour lamp for the operation in steam showers is exclusively carried out by the
company Artweger!

OPERATING INSTRUCTIONS 27/44
3.0.0 FITTING INSTRUCTIONS
3.1.0 DIMENSIONS / FITTING OPERATING ELEMENT + USB DOCK
Operating element: L x W x D = 120 x 92 x 44,5 mm; ~200 g
without cable and loose; differences possible depending on
customer finishes.
USB DOCK: L x W x D= 30 x 92 x 9.5 mm
Recess size: 40 x 25 mm
Fitting suggestion:
To fit the operating element, a normal hole cutter Ø 70 mm
is required.
Insert the colour operating element into the fitting hole and fasten to the sauna wall using the 4
screws supplied. The operating element can be fitted either outside or inside the sauna cabin.
3.2.0 FITTING THE CONTROL ELEMENT
The power element is fitted preferably on the part of the cabin roof
where the cables come together. (see Image. 1) Open the housing.
The cover can be removed. The electrical connection must comply
with standards. The connection diagram is described in Chapter
3.4.0.
Wave.com4
Basismodul
Figure 1

OPERATING INSTRUCTIONS 28/44
3.3.0 FITTING THE COLOURED LAMP
Dimensions
L x W x D = 780 x 185 x 75 mm
light-emitting surface = 620 x 150 mm
Recess size 765 x 158 x 75 mm
~2000 g without cable and loose
Removing the transportation lock
Remove transportation lock from the coloured lamp before using:
Completely unscrew the two set screws on the back side of the housing counter clockwise
with the enclosed socket wrench.
Next insert the two enclosed plastic covers into the vent.
Remove the transportation lock note from the coloured lamp.
Fitting suggestion
Fitting on sauna ceiling not right above the oven (Max. 130°C on the front pain)
Fitting recess 765 x 158 mm; do not enlarge recess, to ensure fitting is water-tight (!).
Rear free for cooling (max. 30°C ambient temperatur e, NB: 80°C housing temperature is
possible)
4 mounting holes are pre-drilled on the front of the coloured lamp
However, depending on the sauna design or the weight of the coloured lamp (approx. 3kg)
further fastening measures (e.g. screws from the front, etc.) may be required
You should also ensure that the coloured lamp is sealed on the sauna ceiling

OPERATING INSTRUCTIONS 29/44
3.4.0 CONNECTION DIAGRAM

OPERATING INSTRUCTIONS 30/44
4.0.0 OPERATING INSTRUCTIONS FOR THE END USER
4.1.0 GENERAL SAFETY NOTICES
Please be aware that the components in the housing of the coloured lamp are operated with
dangerous mains voltage
Do not connect or disconnect any live components! Always isolate the mains connection
beforehand using the appropriate circuit breaker in the building’s distribution system.
Electrical switch-off must be completed in all poles in line with the relevant regulations of the
local Electricity Boards.
Electrical work should only be carried out by a qualified expert. Any interventions by
unauthorised persons shall render the warranty null and void. There is also a risk of serious
electric shocks of live parts are touched.
Keep the controls away from heat sources.
Before start-up, check that all connections are properly connected and that no cables or
parts are damaged

OPERATING INSTRUCTIONS 31/44
4.2.0 OPERATION
4.2.1. FUNCTION DESCRIPTION
The following description gives an overview of the programme functions and operating
elements of the coloured lamp wave.com4 sound&light.
4.2.2. OPERATING ELEMENTS
SWITCH ONE-/OFF
By pressing the key, the coloured lamp and the sound function are switched on or
off.
The colour control changes into the last activated mode (automatic or manual) and the normal
internal lighting goes out. (only in the sauna – operating element slave – mode)
MODE-KEY
By pressing the key, the individual operating modes of the coloured lamp can be
selected.
+/- KEY
By pressing the key, parameters like colour, brightness and volume can be changed.
4.2.3. TABLE OF COLOURS
Each colour number is allocated a chroma. (Standard on delivery).
Colour
number Chroma Brightness Red Green Blue
1 Red 20 20 0 0
2 Yellow 20 20 20 0
3 Green 20 0 20 0
4 Turquoise 20 0 20 20
5 Blue 20 0 0 20
6 Purple 20 20 0 20
7 White 20 20 20 20

OPERATING INSTRUCTIONS 32/44
4.2.4. MODES
Mode Light
Display Symbols Description
Off The coloured lamp is in the standby
mode.
Automatic colour The chroma is automatically further
switched after the programmed time.
The chroma can be manually further
switched. When colour 7 ends, the
control again changes to colour 1
(=rollover). If the mode is activated,
this is shown with “A” on the display.
Brightness The brightness of the particular
chroma can be set in this mode. The
adjusted brightness will be adopted for
all 7 colours (0-20).
Manual The chroma never changes. No time
lapse. The display shows die number
belonging to the active chroma. The
+/- keys can be used to select the
colour desired.
Mode Sound
Display symbols Description
Switch on-/off
Select sound function with Mode key
and by pressing the ON/OFF key, de-
/activate the MP3 function.
When the MP3 function is switched on
again, it starts with the last settings
Play
MP3 is finished, using the +/- T the
previous or the next track can be
selected.
Shuffle
The shuffle mode is activated or
deactivated again by simultaneously
pressing the +/- key. The display
shows ”Shu“. The MP3 files on the
USB stick are played in random order.
AUX
If no USB stick is connected to the
USB dock and the sound function is
selected, the AUX mode is activated.
The music from an external source is
played. (Ipod, MP3-player, radio, etc.)

OPERATING INSTRUCTIONS 33/44
Volume
With Mode key to volume menu.
Volume can be set in stages with +/-
keys (0- 20).
4.3.0 PROGRAMMING FUNCTIONS
The following points provide information on the programmability of the LED coloured lamp.
These settings are stored in a power failure-proof manner
4.3.1. PROGRAMMING CYCLE TIME
The coloured lamp automatically changes, with the exception of ”Manual“ mode, the chroma
when the Cycle time ends. This Cycle time is 5 minutes when delivered. It can be adjusted in
minute steps.
Proceed as follows:
6. On the operating element with the MODE key, go to ”Automatic-colour“
mode.
7. Press the key simultaneously for approx. 3 sec.
8. The programmed cycle time in minutes and the symbol flashes in the display.
9. Use the key to change the cycle time.
10.By pressing the key twice, confirm the input and thus leave the programming.

OPERATING INSTRUCTIONS 34/44
4.3.2 PROGRAMMING COLOUR TRANSITION PERIOD
This is the time the LED control takes on change of colour (manual or at the end of the interval
period), for the colour drift from the current to the next colour.
1. On the control element with the MODE key, go into “Automatic colour“ mode.
2. Press simultaneously for approx. 3 sec
(NB: do not change the colour number in the process!)
3. Pressing the key twice takes you into the setting menu.
4. The current colour transition time in seconds and the symbols and flash.
5. With the keys, the colour transition period is extended or shortened. Each change
of colour the occurs with this programmed time.
6. By pressing the key once, confirm the input and thus leave the programming.
4.3.3 PROGRAMMING COLOURS
The coloured lamp mixes the desired chroma from the 3 LED-base colours (Red-Green-Blue).
This mix can be programmed. This gives the customer the option of programming his personal
colours behind the colour numbers.
Range of the individual components of the colour is always 0 to 20 (5%steps)
9. On the operating element with the MODE key, go into ”Manual“ mode.
10.Press together and simultaneously for approx. 3 sec
(NB: do not change the colour number in the process!)
11.The programmed RED – portion of the chroma flashes in the display.
12.Changeable with and with the MODE key confirm the input

13.The programmed GREEN – portion of the chroma flashes in the display.
14.Changeable with and with the MODE key confirm the input
15.The programmed BLUE – portion of the chroma flashes in the display
16.Changeable with and with the MODE key confirm the input
On completion of all inputs, the control is again in ”Manual“ mode
4.3.2. MASTER / SLAVE PROGRAMMING
Here you can set to decide whether the operating element is used in the
Single/Master operation
Selection „SIN“, (=standard setting,) without Wave.com4 sauna base section as master
Setting for pure colourLEDcontrol without sauna function
or in
Slave operation
Selection „SAU“, with sauna base section as Master
Setting for use with Wave.com4 Sauna control
5. Disconnect 4-pin bus/supply cable from the operating element
6. Simultaneous pressing of the keys
7. Plug in cable again when pressing the key.
8. The display flashes and the mode set for the operating element appears
(SIN or SAU)
5. Set the mode with the keys.
6. Confirm input with the key and jump to the ”Remote start activation“
(see 4.3.5. REMOTE START activate/ deactivate)

4.3.3. REMOTE START ACTIVATE/ DEACTIVATE
In the remote start mode, the coloured lamp switches after connection of the mains voltage to
the last den activated operating mode. (no standby operation) The remote start function is
activated as follows:
4. After setting and confirming the mode (SIN/SAU) by pressing the
key, the remote start setting flashes
(Po0 or Po1)
5. Set the operating mode with the keys.
Po0…….no remote start mode
Po1…….remote start mode active
6. Confirm inputs with to save the changes
5.0.0 CONNECTION OF SEVERAL sound&light COLOURED
LAMPS
Up to 4 sound&light coloured lamps can be controlled via an operating element. To allow this,
the power elements are connected to each other via a BUS line (RJ12 or RJ11 cable) and
controlled via the LED coloured light operating element. The LED coloured lamps connected to
an operating element can not be individually controlled but only together.
There must be a power element defined to which the operating element is connected and from
which the music data (MP3 or AUX) are given.
This is done via a jumper located on the power element board:
Jumper closed (delivery status)Jumper open
Power element MASTER Power element SLAVE

Connection diagram:

6.0.0 CONNECTION TO THE wave.com4 SAUNA CONTROL
Connection diagram:

7.0.0 FAULTS, CAUSES, SOLUTIONS
This list shows possible problems, their causes and recommended procedure for resolving
them.
Fault Possible cause
The display of the colour module cannot
be activated Check power supply to the power element. If this is
in order but none of the symbols on the display
lights, then check the data connection of the
colour operating element;
Colour lamp does not light although the
colour operating element shows colour
numbers
No lamp supply between LED coloured lamp and
LED power element;
Check cables/terminals; and if need be check the
programming (brightness of the individual colours)
The colour of the lamp and the numbers
on the display change but do not
correspond
Check connection sequence of the connection
between LED coloured lamp and LED power
element
One colour and its mixed colours are
missing Check terminal wire of the connection between
LED coloured lamp und LED power element and if
need be check the programming (brightness of the
individual colours)
The colour of the lamp and the numbers
on the display do not change Set to “Automatic“ mode;
If need be connect through manually and if need be
check the programming (interval period of the
individual colours)
The colour of the lamp and the numbers
on the display change automatically Set to “Manual“ mode;
If need be check programming (interval period of
the individual colours)

8.0.0 TECHNICAL DATA
8.1.0 OPERATING ELEMENT
Connection: 4-pin with supply and communication lines (3m)
Power consumption: 5V= / <100 mA normal operation (<0.5 W)
Ambient conditions: 0°C – 130°C, max. 99 % rel. hum idity, non-
condensing!
Housing: Flush-mounted box; board; optical fibre for display;
wooden front with temperature-resistant foil. Board
over M2.5 bolt on wooden front; rear with flush-
mounted box
Mounting: Fasten to the sauna wall with the screws supplied
Dimensions USB-dock: L x W x D= 30 x 92 x 9.5 mm
8.2.0 LED POWER ELEMENT
Supply: 3-pin 230V +/-6%; 50Hz; with protective conductor (PE)
Power consumption: Depending on chroma and brightness max. 50W.
Ambient conditions: 0-50°C, max. 95% rel. h. non-co ndensing
Housing: Plastic housing with cover
L x B x H = 243 x 214.5 x 70 mm
Mounting: Fasten housing with screws to the sauna cabin
8.3.0 LED COLOURED LAMP
Connection: At least 5x0.75mm² +;4x0.5 mm² for Audio with 5m
silicone cable
Power consumption: Depending on chroma and brightness max. 50W
Ambient conditions: Glass surface: max. 130°C outside
Rear: max. 30°C ambient temperature
Housing: L x W x D = 780 x 185 x 75 mm
Light-emitting surface = 620 x 150 mm
Size of recess 765 x 158 x 75 mm
With full timber cabins additional frame into the ceiling
element and make the recess larger accordingly.
Mounting: As per sauna design or with 4 wood screws onto the
sauna ceiling
Other manuals for wave.com4 touch
3
Table of contents
Other Sentiotec Remote Control manuals