www.shieldglobal.com DATA SHEET
Note: Specifications are subject to change without notice
Features
Electronically addressed.
Built-in microprocessor stores 14 history data.
Drift compensation, adaptable to environment
extensively.
Combined smoke and heat algorithm greatly
improves detector performance.
Self-diagnostic.
Dirty chamber checking.
Designed to comply with EN 54-5/EN 54-7
standards.
Description
D-A410 Intelligent Combination Heat/Photoelectric
Smoke Detector integrates photoelectric detection and
fixed temperature and rate of rise detection technology
by combining smoke sensor and heat sensor in
mechanism and circuitry structure. Just because of the
combination of smoke detection and heat detection,
D-A410 detector not only overcomes the disadvantage
that detectors using common infrared scattering
technology are insensitive to black smoke with small
particles, but also can pick up fire with obvious rise of
temperature such as alcohol flame, thus extending its
application range.
Connection and Cabling
Fig. 1 shows the detector bottom and Fig. 2 the base.
100mm
C
Fig.1 Fig.2
Recommended Cabling
1.0 mm2 or above fire cable for detector loop, laid out
through metal conduit or flame-retardant conduit.
Subject to local codes.
Installation
A fixed installation direction is ensured by the location
elements on the detector and the base. Fix the base
with two tapping screws, and then align mark C on the
detector with A on the base, rotate the detector to align
mark C with mark B (Refer to Fig. 1 and 2 for the
position of the marks), the detector will be fitted to the
base.
Mounting of the detector is shown in Fig. 3.
Det ect or
Condui t
Back Box
Base
Fig.3
Application
The detector can be electronically addressed by
D-APP Hand Held Programmer. Please refer to
D-APP Hand Held Programmer Installation and
Operation Manual for details.
D-A410
Intelligent Combination
Heat/Photoelectric Smoke
Detector
Addressable Fire A
larm System
There are four terminals with numbers on the base.
1&3: Loop connection (polarity-insensitive)
2: Positive terminal of remote indicator
4: Negative terminal of remote indicator
www.shieldglobal.com DATA SHEET
Note: Specifications are subject to change without notice
Specification
Operating
Voltage
loop 24V (16V~28V)
Standby
Current
≤0.8mA
Alarm Current ≤5.0mA
Indicator Red. Flashes in polling, and
illuminates in alarming
Alarm
Temperature 58℃
Class A2R
Alarm Temp 58 ℃
Programming
Method
Electronically programming
Code Range one address within 1~242.
Wiring
Ingress
Protection
Rating
IP22
Environment
Temperature
-10℃~+50℃
Relative
Humidity
≤95%, non condensing
Material of
Enclosure
ABS
Dimensions Diameter: 100mm
Height: 56mm(base)
Mounting
Hole Distance
45mm~75mm
Weight About 120g
Maintenance
The detector should be installed just before
commission and kept well before installation.
Corresponding measures should be taken for
dust-proof, damp-proof and corrosion-proof.
Dust covers are an effective way to limit the entry
of dust into smoke detector sensing chambers.
Therefore, the dust cover should not be removed
until the building starts to be used.
Clean the detector at least once 1 year to ensure
normal operation of the system.
If unwanted alarms are often found of the detector
on site, the sensing chamber should be cleaned.
Power must be removed from the detector before
cleaning.
Before cleaning the detector, notify the proper
authorities that the system is undergoing
maintenance and will be temporarily out of service.
Disable the zone or system undergoing
maintenance to avoid any unwanted alarms.
The detector should be tested again after cleaning
and re-installing. Notify the proper authorities
when the system is back in service.
Fire simulation test should be done to the detector
at least once 6 months.
Accessories and Tools
Model Name Remark
D-APP Hand held
programmer
Order separately
DZ-03 Base Order separately
Limited Warranty
SHIELD warrants that the product will be free of
charge for repairing or replacing from defects in design,
materials and workmanship during the warranty period.
This warranty doesn’t cover any product that is found
to have been improperly installed or used in any way
not in accordance with the instructions supplied with
the product. Anybody, including the agents,
distributors or employees, is not in the position to
amend the contents of this warranty. Please contact
your local distributor for products not covered by this
warranty.
Non-polarized 2-core for loop.
Polarized 2-core for remote
indicator.

Popular Security Sensor manuals by other brands

Tecnoalarm MINIEXPLORER manual

Tecnoalarm

Tecnoalarm MINIEXPLORER manual

RKI Instruments 65-2301RKSS Series Operator's manual

RKI Instruments

RKI Instruments 65-2301RKSS Series Operator's manual

Simpson SFI-16.1 installation manual

Simpson

Simpson SFI-16.1 installation manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

pdlux PD-PIR102-Z instruction manual

pdlux

pdlux PD-PIR102-Z instruction manual

LEGRAND 0 625 14 manual

LEGRAND

LEGRAND 0 625 14 manual

Honeywell Searchline Excel Cross-Duct Technical handbook

Honeywell

Honeywell Searchline Excel Cross-Duct Technical handbook

Gardigo 60035 operating instructions

Gardigo

Gardigo 60035 operating instructions

Inficon HLD6000 installation manual

Inficon

Inficon HLD6000 installation manual

Omron ZX-L manual

Omron

Omron ZX-L manual

Elko ineLS RFSF-100 manual

Elko

Elko ineLS RFSF-100 manual

B.E.G. LUXOMAT Indoor 180-M-2C Installation and operating instruction

B.E.G.

B.E.G. LUXOMAT Indoor 180-M-2C Installation and operating instruction

HPM AQUAscan instruction manual

HPM

HPM AQUAscan instruction manual

Bircher Merkur 2 ES.SM Series Translation of the original instructions

Bircher

Bircher Merkur 2 ES.SM Series Translation of the original instructions

Sunx SF4B instruction manual

Sunx

Sunx SF4B instruction manual

Abra AK-325 quick start guide

Abra

Abra AK-325 quick start guide

Lince JOLLY Programming and operating manual

Lince

Lince JOLLY Programming and operating manual

Radiodetection RD8100 Operation manual

Radiodetection

Radiodetection RD8100 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.