Warranty
HPM AQUAscan Weatherproof Movement Sensor
(cat 630/9) are warranted as here and after appears,
against faulty material and/or workmanship for a period
of five years from date of purchase.The obligation of
the manufacturer, under this warranty, is limited to
servicing and replacing defective parts when the unit
is returned to the place of purchase.
This warranty becomes void on any unit which has been
tampered with or damaged by accident, short circuited,
loaded beyond rating or damaged otherwise by
improper operation. The warranty is also conditional on
the unit being installed by qualified electrical contractor.
All other warranties, whether expressed or implied, and
whether arising by operation of law or otherwise are
hereby excluded.
Customer Service & Technical Support
HPM Australia
Tel: 1300 369 777
Fax: 1300 369 780
www.hpm.com.au
AQUAscan Weatherproof Movement Sensor
CAT 630/9 Series
Instruction Manual
1
Warnings
Troubleshooting
Specifications
2 Features
Installation Options: 2-wire (630/9-2W)
3-wire (630/9-3W)
Note: Due to the phase out of standard incandescent lamps, 3 wire version (CAT 630/9-3W) is recommended
for new installations.
Supply Voltage: 230-240V a.c. 50Hz
2 Wire (630/9-2W) 3 Wire (630/9-3W)
Min. Load 10W Incandescent
150VA Fluoro
0W
Max.
Load
1200W Incandescent
1200VA Fluorescent
2400W Incandescent
2400VA Fluorescent
Operating Temp. 0 to 50°C
Mounting height 1.8 to 2.4m
Weatherproof rating IP66
PIR Detection Angle 110 degrees
Contact Status Normally Open
Range Sensitivity
Adjustment
1m to 18 m
Light Sensitivity
Adjustment
1 Lux to Full Sun
Timer Adjustment 15 secs to 7 min
PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION
Light does not switch ON
when there is movement
in the detection area.
1. No mains voltage. Check all connections, circuit breakers and switches.
2. Bulb faulty or missing. Check and replace if required.
3. Nearby lighting is too bright. Redirect the sensor or relocate the unit.
4. Controls set incorrectly. Readjust the sensor angle or control knob.
5. Sensor positioned in wrong direction. Redirect the sensor and/or adjust.
Light switches ON for
no apparent reason
(false trigger).
1. Heat from lamp body activating sensor. Adjust PIR sensor or lamp body to allow a minimum
gap of 40mm between lamp body and sensor head.
2. Heat sources such as air-con, vents,
heater flues, barbecues, other outside
lighting or moving cars are activating
sensor.
Adjust direction of sensor head away from these
sources.
3. Animals/birds e.g. possums or
domestic animals.
Redirecting sensor head may help.
4. Interference from switching off
electric fans or lights on the same circuit
as your sensor.
Should the false triggering become troublesome, consider:
(a) have the other switches checked for arcing faults;
(b) replacing noisy fluorescent tubes and/or starters and
(c) connecting the sensor to a separate circuit. (In most
cases where one or more of the above suggestions have
been carried out, false triggering has been reduced).
5. Reflection from swimming pool or
reflective surfaces.
Redirect sensor.
Light remains on. 1. Continuously false triggered. Redirecting sensor head may help.
2. Time adjustment is set too long. Reduce time.
Light switches on during
daylight.
Lux control knob is set to daylight
position.
Turn the Lux control knob to desired light level setting.
When setting Lux controls in
daylight the detection distance
becomes shorter.
Interference by sunlight. Re-test at night.
Installation: This movement detector must only be connected to a 230-240Vac 50Hz supply by a qualified
electrician. Important: Read all instructions before installation. This instruction manual is to be left at the
installation site.
Figure 1 – Adjustment Knobs
Sensitivity Lux Time
3 Installation
The Movement Detector has been designed for a harsh climate, complying with the strict IP66 rating and
is intended to be used in outdoor installations, however the detector can be installed indoors.
The Detector can be installed on the ceiling surface or on the wall. It can be installed onto a HPM
Surface Mounting Block (HPM Cat No 239) or similar with 84mm mounting centre. Some installation sites
may allow direct surface installation of the Movement Detector. The recommended mounting height of the
Detector is 2.4m.
The head should be oriented in such a way that the expected traffic is moving across the field of view of the
Detector and not directly towards it. Refer to Figure 2.
To change the head orientation, loosen the ball joints by unscrewing the nuts, adjust the head position and
re-tighten the ball joints. Refer to Figure 3 to see different mounting options.
7
8
4
Range Sensitivity
Setting Up
The Detector can be adjusted to react to different levels of movement and at different distances.
At its most sensitive setting it may detect a small child or animal at a full distance. At the least sensitive setting
it may require a large person at a close distance to detect movement.
The Detector may detect movement under certain conditions that could be interpreted as false operation. Ensure you
place the detector carefully, taking into consideration surrounding objects that may be detected by the sensor, such as
passing cars, waves in the swimming pool, tree branches moving in the wind or any other movement of warm objects
or warm air.
These conditions may cause unwanted operation of the Detector, while the Detector itself is still working
correctly. The user has to be aware of these conditions and should take measures to minimize the possibility of
their occurrence.
Note: The range of movement detection depends on external conditions such as the ambient temperature,
body temperature, clothing, speed of movement, etc.
Before the Detector is commissioned for operation it should be tested by a “Walk test”:
1. Set Sensitivity and Lux adjustment knobs, see figure 1, to fully clockwise position and Time knob to fully
anti-clockwise position.
2. Turn the power on and allow 2 minutes for the sensor to warm up before proceeding.
3. Adjust the head position as required.
4. Walk across the Detector’s view range to ensure the light turns on and off.
To setup the Detector for day-to-day operation adjust the knobs so that their settings reflect the desired
mode of operation. Note: Adjusting for the correct light level is dependent on the ambient light and it could
take several days until the right light level setting is found.
Two conduit entries on the mounting base can be used for PAR38 light fittings. These light fittings are
connected to the detector through the supplied terminals. Alternatively, remote loads can be connected
up to the maximum rating. Refer to Figure 4 for electrical connection options.
Note: Different connection and configuration options are possible, e.g. for remote control of Detector’s
operation. All wiring for such circuits must be done by a qualified electrician.
Figure 4
L
Brown
White
N
Blue
Auto
3 wire
Auto
&
ON
override
Auto
&
OFF
override
Auto
&
ON
&
OFF
switch
L
ON
AUTO
Brown
White
N
Blue
Switch: CAT 770RSDM
Switch: CAT 770M
Switch: CAT 770M
ON
L
OFF
AUTO
Brown
White
N
Blue
L
OFF
AUTO
Brown
White
N
Blue
2 wire
L
Brown
N
Blue
L
Brown
N
Blue
N
Blue
Switch: CAT 770M
Switch: CAT 770RSDM
Switch: CAT 770M
Brown
N
Blue
L
Brown
L
ON
AUTO
OFF
AUTO
ON
OFF
AUTO
Figure 2 Figure 3
Normal Traffic
TOP VIEW 630/9 Ceiling
Wall
SIDE VIEW
TOP VIEW
90º90º
90º
65º 5Operation
Thedetectorwillturntheloadonifawarmbodymovesinits viewingrange.TheRangeSensitivityadjustment knobdetermines therange.
The Movement Detector can be setup so that it only turns the load on when it is dark. The setting of the Lux adjustment knob
determines the light level at which the Detector starts operating the load.
The load stays turned on for a predetermined amount of time. The time that the load stays turned on depends on the setting
of the Timer adjustment knob.
Light Sensitivity
The Movement Detector can be setup to operate during different light conditions, such as night only or day and night.
At the minimum ‘Lux’ control setting the sensor will detect movement only when it is dark. At the maximum setting the
sensor will operate during day and night. In that way users can adjust the operating conditions to suit their needs and
save energy.
Note: A small plastic screwdriver is supplied as an adjustment tool.
Timer
The time that the load stays turned on can be varied from 15 secs to 7 mins. Rotating the ‘Time’ knob anti-clockwise
reduces load ‘ON’ duration. This feature allows the user to balance energy savings and convenience.
6
Two-wire devices draw their power through the load.
Some loads might not provide enough power for the
Detector to operate or are sensitive to high off-state
leakage currents e.g. relays. In such cases a mains
voltage rated capacitor of 2-10uF should be connected
in parallel with the load. Refer to Figure 5 for information
on how to connect the capacitor.
For some inductive loads this capacitor could cause
resonance, seen as a high off-state voltage across the load.
In such case the value of the capacitor should be changed.
2-Wire (630/9-2W) Option
2 wire option
L
Brown
Blue N
Figure 5

Popular Security Sensor manuals by other brands

CSP Pacific BarrierGuard 800 installation manual

CSP Pacific

CSP Pacific BarrierGuard 800 installation manual

Besam SR221-2 quick start guide

Besam

Besam SR221-2 quick start guide

Optigene Genie HT user manual

Optigene

Optigene Genie HT user manual

LACO Technologies TITAN VERSA C Operation and maintenance manual

LACO Technologies

LACO Technologies TITAN VERSA C Operation and maintenance manual

Emerson REED Series manual

Emerson

Emerson REED Series manual

Allen-Bradley SensaGuard 440N-Z21SS2H-AS installation instructions

Allen-Bradley

Allen-Bradley SensaGuard 440N-Z21SS2H-AS installation instructions

Monacor PIR-100D manual

Monacor

Monacor PIR-100D manual

Danieli Automation ID2202 Installation, use and maintenance manual

Danieli Automation

Danieli Automation ID2202 Installation, use and maintenance manual

Optex OVS-01CC Quick reference guide

Optex

Optex OVS-01CC Quick reference guide

Tecnoalarm EXPLORER II Instructions for use

Tecnoalarm

Tecnoalarm EXPLORER II Instructions for use

Evikon E2610-LEL user manual

Evikon

Evikon E2610-LEL user manual

PCB Piezotronics 4204-03A Installation and operating manual

PCB Piezotronics

PCB Piezotronics 4204-03A Installation and operating manual

V-GREAT VG-6617 Installation and operation manual

V-GREAT

V-GREAT VG-6617 Installation and operation manual

MICRO-EPSILON WPS Series operating instructions

MICRO-EPSILON

MICRO-EPSILON WPS Series operating instructions

DAITEM 145-21X installation manual

DAITEM

DAITEM 145-21X installation manual

Atom AT4105 instruction manual

Atom

Atom AT4105 instruction manual

Omron ZS-HL Series user manual

Omron

Omron ZS-HL Series user manual

ELN-Sicherheitstechnik OCTOPUS Operating	 instruction

ELN-Sicherheitstechnik

ELN-Sicherheitstechnik OCTOPUS Operating instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.