Shuang Ri SR201 User manual

Please read the manual carefully before operation!

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-1-
Contents
1. Safety information ......................................................................................................3
1.1 Installation and commissioning.................................................................................3
1.2 Liability waiver..........................................................................................................3
1.3 Signal description.....................................................................................................4
2. Installation..................................................................................................................4
2.1 Mounting controller...................................................................................................4
2.2 Power connection.....................................................................................................5
2.3 Terminal port connection ..........................................................................................5
2.4Installation of solenoid valve......................................................................................6
2.5 Installation of sensor of temperature and water level ...............................................7
3.System diagram ..........................................................................................................8
4. Functions operation....................................................................................................9
4.1 Signals on display and function code.......................................................................9
4.2 Button description.....................................................................................................9
4.3 Menu description....................................................................................................10
5. Main functions setup.................................................................................................11
5.1 Time setting............................................................................................................11
5.2 Timing filling and heating with three time-sections .................................................11
5.3Pipe insulation (belt-cable heating) function............................................................13
5.4 Booster pump function............................................................................................14
5.5 Hot water circulation...............................................................................................14
5.6 Delay time of water filling when tank is lack-of water .............................................14

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-2-
5.7 Celsius degree and Fahrenheit unit switch.............................................................15
5.8 BEEP Beeper error warning...................................................................................15
5.9 Compulsive water filling function............................................................................15
5.10 Factory reset manually function............................................................................15
6. Manual functions ......................................................................................................15
6.1 Manual water filling.................................................................................................15
6.3 Manual heating.......................................................................................................16
7. Protection function....................................................................................................16
7.1Tank high temperature protection function...............................................................16
7.2 High temperature protection of collector tube.........................................................17
7.3 Tank anti-freezing protection ..................................................................................17
7.4 low water pressure protection.................................................................................17
7.5 Overflow protection.................................................................................................18
7.6 Memory protection..................................................................................................18
7.7 Screen protection...................................................................................................18
7.8 Trouble protection...................................................................................................18
8. Quality Guarantee ....................................................................................................19
9. Technical specification..............................................................................................19
10. Delivery list.............................................................................................................19

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-3-
1. Safety information
We have carefully checked the text and pictures of this manual and provided the best of
our knowledge and ideas, however inevitable errors maybe exist. Please note that we
cannot guarantee that this manual is given in the integrity of image and text, incorrect,
incomplete and erroneous information and the resulting damage we do not take
responsibility.
1.1 Installation and commissioning
When laying wires, please ensure that no damage occurs to any of the
constructional fire safety measures presented in the building.
The controller must not be installed in rooms where easily inflammable gas
mixtures are presented or may occur.
The permissible environmental conditions can’t be exceeded at the site of
installation.
Before connecting the device, make sure that the power supply matches the
specifications that controller requires.
All devices connected to the controller must conform to the technical specifications
of the controller.
All operations on an open controller are only to be conducted cleared from the
power supply. All safety regulations for working on the power supply are valid.
Connecting and /or all operations that require opening the collector (e.g. changing
the fuse) are only conducted by specialists.
1.2 Liability waiver
The manufacturer can’t monitor the compliance with these instructions or the
circumstances and methods used for installation, operation, utilization and maintenance
of this controller. Improper installation can cause damages to material and person. This
is the reason why we do not take over responsibility and liability for losses, damages or
cost that might arise due to improper
installation, operation or wrong utilization and maintenance or that occurs in some
connection with the above-mentioned. Moreover, we do not take over liability for patent

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-4-
infringements or infringements occurring with the use of this controller on the third
parties’ rights. The manufacturer reserves the right to put changes to product, technical
data or installation and operation instructions without prior notice. As soon as it
becomes evident that safe operation is no longer possible (e.g. visible damage). Please
immediately take the device out of operation. Note: ensure that the device can’t be
accidentally placed into operation.
1.3 Signal description
Safety indication: Safety instructions in the text are marked with a warning triangle.
They indicate measures which can lead to injury of person or safety risks.
Operation steps: small triangle “►”is used to indicate operation step.
Notes: Contains important information about operation or functions.
2. Installation
2.1 Mounting controller
Dimension of controller:

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-5-
This controller can only be installed in the place having an adequate level of protection.
►Choosing a suitable site
►Drilling the upper fixing hole ①
►Screwing on the screw
►Taking away terminal cover
►Marking the position of bottom fixing hole ②
►Taking away the bottom plate
►Drilling the hole ②
►Re-hanging the bottom plate on screw ①
►Fixing bottom plate with screw ②
2.2 Power connection
Depending on the type of installation, the cables may enter the device through the rear
hole of the case ③or the base side hole of the case ④
Notes: the flexible wire must be fastened to the case using the strain-relief clamps
provided.
③③④④
2.3 Terminal port connection
Before opening the terminal, please be sure to switch-off the power and pay
attention to the local electricity supply rules.

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-6-
Power input L, N: 10A, for power connection, L: live wire, N: zero wire, protective
ground wire, please connect it to ground reliably.
FU: the fuse of controller, AC250V/2A
Output ports
HR: Electromagnetic relays, designed for on/off control of back-up heating device, Max.
Current: 10A
R2: designed for electromagnetic relay use for the electric tracing belt(or Booster pump
or hot water circulation pump), maximum current is 2A.
R1:designed for the solenoid valve of water filling, output power is DC12V, wire
connection is not positive and negative difference.
With Auxiliary electrical heating, the user must install the leakage protector
himself.
Input ports
Sensor of water temperature and water level of the water tank(B03):
Port 1: connect red wire (+12V)
Port 2: connect white wire (COM)
Port 3: connect black wire (GND)
2.4Installation of solenoid valve
Flushing pipe and cleaning pipe before mounting the solenoid valve
If water is provided by water tower, to avoid no water filling or water flow rate is too
low at solenoid valve, please select the solenoid valve which pressure is matched
to the hydraulic pressure got from water tower.

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-7-
Check whether the required voltage labelled on the type plate of solenoid valve is
same to the voltage of power output of controller, check whether the filter of
solenoid valve is completed,
whether the body of valve has
no damage. And during
installation please pay attention
to the water flow and return of
solenoid valve, side with filter is
the water input, water flow
direction and arrow signal on
the body of solenoid valve should be aligned in same direction.
Solenoid valve should be indoor installed at the place where is easy for
maintenance or at the area where no more connected loss happened. To keep a
long lifetime of solenoid valve, please pay attention to anti-frost, sun protection
and prevent broken damage from freezing or aging of body of solenoid valve.
It is prohibited to use a wrench worked on the coil wire and plastic parts, to ensure
no damaged during installation and no torsion effect positioned on the solenoid
valve, it is not allowed to install valve compulsively when tow connectors are not
aligned.
Two-core wire is used for connection with solenoid valve, if wire needs to be
lengthened, please select cable of 1.0mm2.
To easy clean the filter, water inlet pipe connected to the solenoid valve should be
a kind of soft pipe or pipe is easily dismounted.
Note: one-way check valve integrated into the solenoid valve, so no one-way
valve needs to be installed.
2.5 Installation of sensor of temperature and water level
Sensor of water temperature and water level is inserted into tank from the overflow
connector.
Fasten sensor with the mutter of sensor.
3-cores wire of sensor connected to the input port of controller

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-8-
Note:
1). Depending on the way of difference installation, we provide two different sensors,
and the customer chooses one of them as
needed. If the customer does not specify
anything, we will follow the factory default
configuration.
a) ”Side mounted sensor”
(Factory default configuration) see the picture 1
b). ”Top mounted sensor”
(Need to be specified in order) see the picture2
2). To avoid the measuring error or damage the sensor, sensor of temperature and
water level must not touch or close to the e-heater tube
3.System diagram
Note: this diagram is only for reference.

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-9-
4. Functions operation
Before switching-on the power, please connect sensor of temperature and water level,
water filling solenoid valve to the input port of controller, connect electrical heater to the
output port of controller. And then switching-on power, you can set the time and related
parameters of the controller.
4.1 Signals on display and function code
LCD display screen
4.2 Button description
Buttons layout on the controller
Button description
“Water Loading” button: water filling manually
“HEAT” button: heating manually
“SET” button: access the menu or activate the set value
“ESC” button: confirm the setting value and ESC or return to the previous menu
“▲” button: increase adjustable value or upwards menu
“▼" button: decrease adjustable value or downwards menu
Hold press“Water Loading” button for 3s, switch on/off the booster pump.

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-10-
Hold Press “INSU” for 3 seconds: switch on/off Pipe Insulation (Belt-cable
heating).
Hold Press “CYCLE” for 3 seconds: switch on/off manual hot water circulation
function
Hold Press “ESC” button for 3 seconds: Celsius degree and Fahrenheit exchange.
Note:
1. When controller works at normal status, by pressing “▲▼”button, it is possible to
view controller running time (DAYS), sensor running time(SDAY), software version(SW)
and sensor version(S SW).
2. if without any operate during 3s,the controller works back to normal work interface.
4.3 Menu description
Main functions menu (for users)
Code
(Main
menu)
Code
(Submenu)
Default value
Description
Clock
Clock
Time Water
Timing water filling
Time Water①
03:00 / 50%
Time and water level of the 1st time
water filling
Time Water②
09:00 /100%
Time and water level of the 2nd time
water filling
Time Water③
16:00 / 100%
Time and water level of the 3rd time
water filling
Time Heat
Timing heating
Time Heat①
04:00 / 50℃
Time and temperature of the1st time
water heating
Time Heat②
10:00 / 0℃
Time and water level of the 2nd time
water heating
Time Heat③
17:00 / 60℃
Time and water level of the 3rd time
water heating

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-11-
5. Main functions setup
5.1 Time setting
►Press “SET” button, time displays on the screen,
►Press “SET” button again, hour “00” blinks on the screen.
►Press “▲▼” button to set hour of clock
►Repress “SET”, minute “00” blinks
►Press “▲▼” button to set minute of clock.
►Press “SET” or “ESC” to confirm setting, the set parameters are saved automatically.
Note: at the case that power is switched-off, time can be remembered for 36
hours.
5.2 Timing filling and heating with three time-sections
Timing water filling description:
Within 24 hours, three time-sections of water filling can be set.When time of filling water
comes, water is automatically filled into tank to the set water level. When water is being
used (water level drops), the water filling is delayed for 30 minutes to start.
Timing heating description:
Electrical heater can be integrated into solar system used as back-up heating of system,
and it can be triggered automatically at preset time by preset temperature. Within a
preset time-section, when the temperature of tank drops below the preset switch-on
temperature of this function, electrical heater starts to work, when temperature rises to
the preset switch-off temperature, electrical heater is stopped.When water level is lower
than 50% during a heating time-section, to avoid a dry heating, water is filled to the level
of 50% firstly, then the electrical heater is triggered to heat to the desired temperature.
Timing filling and heating factory default reference as below:
• The first time: at 3:00 a.m. to fill water to the water level of 50%, at 4:00 a.m. to trigger
electrical heater to heat water to the temperature of 50oC, to provide hot water for users
just after getting up.
• The second time: at 9:00 a.m. to fill water to the water level of 100%, and electrical
heater doesn’t work, to use solar irradiation to heat water.
• The third time: at 16:00 p.m. to fill water to the water level of 100%, and at 17:00
p.m.to trigger electrical heater to heat water up to the temperature of 60oC for night

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-12-
using.
Note:
1. Above parameters can be set base on the user's habit.
2. When water is using by user (water level drops),then water filling is delayed for 30
minutes to start.
3. Activate and deactivate the function of heating with three time-sections as below:
Hold “HEAT” button for 3 seconds to deactivate “timing heating” function. Heating
icon was disappeared and show
Hold “HEAT” button for 3 seconds to activate “timing filling” function. Heating icon
display and show
Code
(Main
menu)
Code
(Submenu
)
Default value
Adjustable
arange
Description
Time Water
Timing water filling
Time
Water①
03:00 / 50%
00:00- 23:59
20-100%
Time and water level of the
1st time water filling
Time
Water②
09:00 /100%
00:00- 23:59
20-100%
Time and water level of the
2nd time water filling
Time
Water③
16:00 / 100%
00:00- 23:59
20-100%
Time and water level of the
3rd time water filling
Time Heat
Timing heating
Time Heat
①
04:00 / 50℃
00:00- 23:59
0-95℃
Time and temperature of
the1st time water heating
Time Heat
②
10:00 / 0℃
00:00- 23:59
0-95℃
Time and water level of the
2nd time water heating
Time Heat
③
17:00 / 60℃
00:00- 23:59
0-95℃
Time and water level of the
3rd time water heating
Setup steps:
►Press “SET” button, time displays on the screen.
►Press “▲” button, time of the 1st timing water filling (Time
Water ①) 03:00,water level 50% displays.
►Press “SET” button, hour “03” blinks on the screen.
►Press “▲▼” button, to set hour
►Press “SET” button, minute “00” blinks on the screen.

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-13-
►Press “▲▼” button, to set minute
►Press “SET” button, water level “50%” blinks on the screen.
►Press “▲▼” button, to set water level
►Press “SET” or “ESC” button to confirm the setting.
►Press “▲” button, time of the 2nd timing water filling (Time Water ②) displays.
Repeat above steps to set the time and water level of the second and the third of timing
water filling (“Time Water ②” and “Time Water ③” ).
►Press “▲” button, timing heating “Time Heat ①” displays.
►Press “SET” button, hour “04” blinks on the screen.
►Press “▲▼” button, to set hour
►Press “SET” button, minute “00” blinks on the screen.
►Press “▲▼” button, to set minute
►Press “SET” button, temperature “50oC” blinks on the screen.
►Press “▲▼” button, to set temperature ( adjustable range:0-90oC)
►Press “SET” or “ESC” button to confirm the setting.
Repeat above steps to set the time and temperature of the second and the third of
timing heating (“Time Heat ②"and “Time Heat ③").
5.3Pipe insulation (belt-cable heating) function
Function Description:
After switch on the belt-cable heating (default: R2 heating for 10mins, which can’t be
set), stop for 30 minutes (stop time adjustment range: 0-90 minutes). This process will
automatically run repeatedly, which can avoid long-term power on belt-cable, save
electric energy, and effectively prevent malignant accidents such as aging and fire of
the belt-cable caused by long-term power on.
Switch on/off the function:
►Hold press the "INSU" button for 3 seconds, to activate the function, and the pipeline
freeze protection stop time is "30” minutes.
►Press“▲/▼”button, adjust the running time, adjustable time: 0-90Mins, default is
30mins.
►Hold press "INSU" button for 3s to deactivate the function immediately.

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-14-
5.4 Booster pump function
Function description:
In some areas with low pressure water supply, a booster water pump (R2) is necessary.
When the conditions are met, the booster pump R2 and the solenoid valve R1 are ON
or OFF at the same time.
►Hold press“Water Loading” button for 3s, switch on the booster pump.
►Hold press“Water Loading” button for 3s, switch off the booster pump.
5.5 Hot water circulation.
Function Description: The hot water circulating pump can operate by manually.
►Hold Press “CYCLE” for 3 seconds: switch on the function, and cycle time ”03”
display on screen.
►Press“▲/▼”button, adjust the running time, adjustable time: 1-60Mins,default is
3mins.
►Press “ESC” button or wait for 6s to activate the function and "Hot water
circulation" icon blink on the screen .
►Hold press“CYCLE”button for 3s to deactivate the function immediately.
Note:
1. No matter one of the three (Booster pump or Belt-cable heating or Hot water
circulation) needs to occupy the output R2, So one of the functions is on, the other
two functions are automatically off.
2. For example, the booster pump function is currently on. Now, you need turn on the
belt-cable heating function. Please hold press”INSU”button for 3seconds,it’s
mean that you activate the belt-cable heating and the booster pump function are
automatically off.
5.6 Delay time of water filling when tank is lack-of water
Function description:
When the water level drops from high to low, when the water level is lower than 20%, it
will automatically fill to 50% water level after a delay of 30 minutes.

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-15-
5.7 Celsius degree and Fahrenheit unit switch
►Hold press ”ESC” button for 3s,switch on Fahrenheit degree.
5.8 BEEP Beeper error warning
When temperature and water level sensor has error, this function will send warning to
manager (detailed see section7.8 error code).When beeper make sound, press any
button to escape the warning function.
5.9 Compulsive water filling function
Description:
If sensor of temperature and water level is out of working, “E0” displays on the screen,
then you can trigger water filling function compulsively.
►Hold Press “Water Loading” button for 3 seconds to trigger compulsive water filling
function, (countdown 8 minutes), countdown time and water level of 0%,20%,50%,80%
and 100% displays on the screen alternatively.
►Press “Water Loading” button again to stop the compulsive water filling function
5.10 Factory reset manually function
Through this function, it is possible to recover all parameters to the factory set.
Setup steps:
Under power-off status
►Hold “SET” button, then switch-on power, screen displays “MRST”, beeper sounds
“di….” 3 times, and then release “SET” button, it indicates the controller program is
recovered to the factory set.
6. Manual functions
6.1 Manual water filling
Description:
When water in the solar tank is not full, user needs to fill water immediately, then press
“Water Loading” button to start water filling.
Activate and deactivate this function:

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-16-
►Press “Water Loading” button, then water level of water filling signal blinks on the
screen
►Continuously press “Water Loading” button, water level of tank can be set
(50%-100%)
►Press “ESC” button or wait for 6 seconds to confirm the setting, and water is filling
now.
6.3 Manual heating
Description:
It is possible to trigger back-up heater manually to heat the water to the desired
temperature. When controller detects that the water temperature is lower than the
preset switch-on temperature of manual heating function, controller will trigger heater to
work until the water temperature rises to the desired temperature.
Activate and deactivate the function:
►Press “HEAT” button, temperature “60oC” displays on the
screen.
►Press“▲▼”button to adjust the desired temperature,
adjustable range: 0oC -80oC, factory set is 60oC.
►Press “HEAT” or “ESC” button or wait for 6 seconds to confirm the setting, heater
starts to work, and manual heating signal blinks on the screen.
►Press “HEAT” again to cease the manual heating function.
Note: manual heating can only heat tank once, when manual heating function is
triggered, water is heated to the desired temperature and then heating is stopped, this
function is deactivated automatically.
7. Protection function
7.1Tank high temperature protection function
Description:
To prevent tank from damaging caused by high temperature, when tank temperature
rises to the switch-on protection temperature, default is 70oC, water filling will be
triggered, it will stop until tank temperature drops to 68oC (default set is 2oC hysteretic)

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-17-
or water level is to 100%. When water is using (water level is dropping), then water
filling is delayed for 30 minutes to start. (this tank protection function is time limited, it
can only be triggered from 8:00-17:00).
7.2 High temperature protection of collector tube
Description:
When water level is lower than 20% and water temperature is higher than 95oC, to avoid
the collector tube exploded due to the thermal stress, water filling function will be
stopped compulsively (“Water Loading” button is unable), and “E4” displays on the
screen. When water temperature drops below 80oC,this protection function is
deactivated, and water filling function is recovered.
7.3 Tank anti-freezing protection
Description:
In winter, when outdoor temperature is very low, to avoid freezing of collector tube/ tank,
when controller measures the tank temperature drops to only 3oC (factory set, not
adjustable), controller will trigger the electrical heater to heat tank until its temperature
rises to 7oC, and then tank anti-freezing function is deactivated automatically.
When anti-freezing signal blinks, it indicates anti-freezing function is running.
7.4 low water pressure protection
Function description:
In the process of water supply, because of low water pressure, water cut-off, vacuum
pipe rupture or water leakage, the controller will automatically enter the low water
pressure mode.
The icon of "low water pressure" shows on screen. After 60 minutes, controller will exit
the low water pressure protection and refill the water. During water filling process, the
water level drop down "0",the icon of "low water pressure" is flash, and the controller
automatically turns off the water filling function.
under state of low water pressure protection, press the "water loading" button to restore
the water supply function immediately.

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-18-
Note:
When the "low water pressure" icon flashes:
1. Check whether the vacuum pipe is broken or leaking
2. Check whether the water pressure of tap water is normal
3. After the problem is eliminated, press the "water loading" button to start the water
supply.
7.5 Overflow protection
When the water temperature and level sensor fails, causing the water tank overflow, the
controller will automatically stop the water supply.
7.6 Memory protection
In case power failure occurs, controller keeps the parameter settings unchanged.
7.7 Screen protection
When no any press on button for 5 minutes, screen protection is activated automatically,
and
LED backlight is dimmed by light. Through press any button to light LCD lamp again.
7.8 Trouble protection
Error code
Display status
Error description
E0
Temperature zone displays
“E0”
Communication fault between controller
and sensor of temperature and water
level
E4
E4 and clock signal displays
alternatively in every 4
seconds.
Collector tube high temperature
protection
----
Temperature zone displays
"---- "
Temperature fault of sensor of
temperature and water level

Instrcution SR201 for Un-pressurized Integrated Solar Hot Water Heater
-19-
8. Quality Guarantee
The warrantee expires within 12 months after the date of purchasing the controller.
9. Technical specification
Power supply:100-240V/AC,50-60Hz
Power consumption:< 2W
Accuracy of temperature measuring:±1oC
Range of tank temperature measuring:0 ~100 oC
Inputs: temperature and water level sensor
Outputs:3electromagnetic relays
Ambient temperature :-10oC ~ 50oC.
Water proof grade:IP40.
10. Delivery list
Controller--------------------------------------------------------------------------------------------1piece
User manual----------------------------------------------------------------------------------------1piece
Sensor of water temperature and water level (with cable of 20m) -------------------1piece
Solenoid valve --------------------------------------------------------------------------------------1piece
Accessories------------------------------------------------------------------------------------------1bag
10A power cable----------------------------------------------------------------------------------1piece
-88.8oC
Temperature zone displays
"-88.8 oC "
E7
E7 and clock signal displays
alternatively in every 4
seconds.
Water level fault of sensor of
temperature and water level