Siegenia Sensoair User manual

Window systems
Door systems
Comfort systems
AERO
Air quality sensor for indoor use.
SENSOAIR
INSTALLATION AND
OPERATING INSTRUCTIONS

SENSOAIR Installation and operating instructions
2 03.2017
Contents
1. Target group of this documentation...............................................................................................3
2. Intended use ...................................................................................................................................3
3. Safety notes....................................................................................................................................4
4. Description of device......................................................................................................................5
5. Installation ......................................................................................................................................6
6. Wiring diagrams for SENSOAIR plus ...........................................................................................11
7. Device control.................................................................................................................................13
8. Commissioning...............................................................................................................................15
9. Care and maintenance ..................................................................................................................15
10. Rectification of malfunctions........................................................................................................16
11. Technical specifications...............................................................................................................17
12. Information concerning product liability.....................................................................................18
13. Feedback on documentation....................................................................................................... 18
14. EU Declaration of Conformity with regard to CE marking ......................................................... 19

Installation and operating instructions SENSOAIR
03.2017 3
1. Target group of this documentation
•This documentation is intended for use by specialists and end users.
•All instructions concerning assembly, installation and repairs described in this document are to be
performed exclusively by electricians with training and practice in the installation, commissioning,
servicing and maintenance of home automation devices and electrical installation.
•All instructions on operation, care and maintenance as well as rectification of disturbance described
here are intended for specialists as well as end users.
•Following installation, the installation company must hand over the installation and operating
instructions to the end user.
2. Intended use
•The device is only to be used for measurement and control purposes in closed, dry and dust-free
rooms.
•Maintain a room temperature of 5 °C – 40 °C.
•This device is not suitable for use as a measuring device or as part of a gas warning or similar safety
device.
•Do not use solvents near the device.
•Silicon vapours can have an effect on how the device works.
•Use the unit only with original accessories from SIEGENIA.
•The device must always be installed by an experienced specialist, in accordance with the installation
and planning documents of SIEGENIA. The installation instructions in this document must be
complied with at all times.
•Use the unit only when it is in a technically sound condition.
Do not modify the device's components in any way.
•It must be ensured that indoor air is circulating round the SENSOAIR.
•Ensure that the device's ventilation openings are kept free and are not blocked by other equipment,
furniture or objects.
•The unit must be checked by a specialist in the event of a fault.

SENSOAIR Installation and operating instructions
4 03.2017
3. Safety notes
• This unit can be used by children aged 8 and above as well as by people with physical, sensory or
mental difficulties or with a lack of experience and knowledge as long as they are supervised or
have been instructed in how to use the unit safely and understand the resulting risks. Children must
not play with the unit. Cleaning and user maintenance must not be carried out by children without
supervision.
• Electrically operated unit. Risk of fatal injury from electric shock or fire.
To prevent personal injury or damage to property, always comply with the following instructions:
- Insert the Euro mains plug of the standard connecting cable only into a suitable 230VAC mains
power supply socket.
- If the mains connection cable for the unit is damaged, it must be replaced by SIEGENIA, its
customer service or an equally qualified person to eliminate hazards.
- Only a qualified electrician may perform any work on the 230V AC mains power supply that is
required in order to connect the unit.
- All-pole safety isolation is required if the customer is routing the mains cable.
- Current local regulations (such as those of the VDE in Germany) must be observed.
- Relevant country-specific regulations must be strictly followed for all work carried out on the
voltage supply system or house wiring system.
- Do not connect the control line and low voltage connections of the device with the 230V
AC mains power supply. This can destroy all connected devices.
- Should a solid object or any liquid get inside the unit, stop operation immediately and
disconnect the unit from the mains power supply.
• Hazard due to third party attacks on SIEGENIA WLAN devices! Please observe the following notes
to protect your system against attacks by third parties:
- Every SIEGENIA WLAN device is protected by two passwords (user and administrator). It is
essential that you change these passwords after the initial setup. Do not leave in the default
setting.
- If the SIEGENIA WLAN devices are integrated in your home WLAN, this must be encrypted for
operation.
- Please choose secure passwords consisting of lower case and capital letters, numbers and
special symbols.

Installation and operating instructions SENSOAIR
03.2017 5
4. Description of device
The SENSOAIR is an air sensor for checking the quality of air in closed rooms.
4.1 Device types
SENSOAIR type plus smart
Table unit version −
Wall-mounted version
Measure/display CO2function
Measure/display VOC* function
Device control by cable via WLAN
* Volatile Organic Compound: In the form of gases, such as cigarette smoke, perspiration and kitchen odours etc.
4.2 Function
The quality of the air that has been measured is shown using an LED indicator (traffic light system).
LED indicator Signal Ventilation
Red Flashes 2x briefly Urgently required
Flashes 1x long
Red Permanently illuminated Required
Yellow/Red Permanently illuminated
Yellow Permanently illuminated Recommended
Green/Yellow Permanently illuminated Not necessary
Green Permanently illuminated
Red = Poor air quality – ventilation is required
Yellow = Medium air quality – ventilation is recommended
Green = The air quality is good

SENSOAIR Installation and operating instructions
6 03.2017
5. Installation
5.1 Installation requirements
• Suitable installation location:
- Ideally, use a wall-mounted outlet box
- Not in the immediate vicinity of windows, ventilation devices and people or animals
• A smooth and even wall
• Maintain a temperature of 5°C–40°C during installation
• During installation and before initial operation protect the device against:
- Dirt (e.g. cover ventilation grilles when wallpapering, etc.)
- Draught and directly exhaled air
- Direct sunlight
Exposed electrical components.
Danger due to short circuit or fire.
›Make sure that the power is isolated before installation.
›The fuses may need to be removed.
5.2 Additional requirements for SENSOAIR smart
• The SENSOAIR should be installed to be as free from interference as possible.
The following interferences can have a negative influence on the WLAN signal:
- Water lines
- Stone and concrete walls
- Metal objects
- Air conditioning units
- Wireless devices (e. g. radio telephones, baby monitors, Bluetooth loudspeakers, etc.)
- WLAN networks on the same wireless channels (e. g. the neighbour's WLAN router)
• If energy-carrying cables are routed in parallel to data cables (ISDN, DSL, etc.), this could lead
to interference e.g. in the speed of the data transmission.

Installation and operating instructions SENSOAIR
03.2017 7
5.3 Installation steps
1. Remove the casing cover
Note: In the delivered state, the cover is not clipped on. If it does need to be removed, insert a
suitable object (e.g. coin or screwdriver) into the gap in the retention catches and twist to lever
the cover off the casing.
2. Remove the pre-punched drill hole cut-outs and the power cable cut-out (depending on the
device) using a suitable tool:
a= Drill hole cut-outs
b= Power cable cut-out for 230 V AC
c= Power cable cut-out for 24 V DC
c
b
a
a

SENSOAIR Installation and operating instructions
8 03.2017
3. Pull the power cable through the relevant cable cut-out (bor c).
4. Position the bottom part of the casing and use it as a drilling template.
5. Drill the holes for wall mounting.
6. Fix the bottom part of the casing using two 4mm x 30mm screws and dowels (included).
7. Connect the power cable for 230 V AC or 24 V DC.
1 2 3 4
ON
b
c
230 V DC
24 V DC

Installation and operating instructions SENSOAIR
03.2017 9
8. Optional: Connect devices (SENSOAIR plus only).
- SENSOAIR plus controls the connected devices via 230 V AC or 24 V DC control lines.
- The devices are connected to a relay circuit board.
- For wiring diagrams see from Page 4
1 2 3 4
ON
Relay circuit board
Relay circuit board
Relay circuit board
Mains circuit board
Mains circuit board
Basic circuit board
(without mains circuit board)
24V DC control lines
230V AC control lines
230V AC / 24V DC
control lines

Installation and operating instructions SENSOAIR
03.2017 11
6. Wiring diagrams for SENSOAIR plus
6.1 Ventilation units
AEROMAT VT RS,
AEROMAT VT WRG 1000
AEROMAT VT WRG 1100
AEROVITAL, AEROLIFE,
AEROPLUS, AEROPAC SN,
AEROVITAL ambience
AEROMAT VT RS
AEROMAT VT WRG
SENSOAIR plus SENSOAIR plus
AEROVITAL, AEROLIFE,
AEROPLUS, AEROPAC SN,
AEROVITAL ambience
AEROMAT 100 DK type AEROMAT 150 DK type
SENSOAIR plus
AEROMAT 100 DK
AEROMAT 150 DK
SENSOAIR plus
Relay 1
Relay 2
Switch distribution box, provided by
customer
Relay 1
Relay 2
Switch distribution box, provided by
customer
Relay 1
Relay 2
Switch distribution box, provided by
customer
Switch distribution box, provided
by customer
Relay 1
Relay 2

SENSOAIR Installation and operating instructions
12 03.2017
6.2 Motor-driven window drives
Motorised handle MH10 DRIVE axxent DK
MH10
SENSOAIR plus
M- 24 V DC
Switch distribution box, provided
by customer
Power supply VPS1
DRIVE
axxent DK
SENSOAIR plus
M- 24 V DC
Switch distribution box, provided
by customer
Power supply VPS1
CLOSED
OPEN
+−
sw = black
rt = red
sw rt
Motion chain drives
SENSOAIR plus
M- 24 V DC
SENSOAIR plus
M~230 V AC
Relay 1
Relay 2
Switch distribution box, provided by
customer
Power supply
ACX
Chain
drive
Switch distribution box, provided
by customer
Relay 1
Relay 2
Chain
drive

Installation and operating instructions SENSOAIR
03.2017 13
7. Device control
7.2 SENSOAIR plus
• All connected devices are activated/deactivated using preset air quality values.
• The presettings are made by means of DIP switches on the basic circuit board.
Important: Do not switch on the power supply until all DIP switches have been configured.
Switch 1:
OFF
Switch 1:
ON
Switching examples
Ventilation units
DIP switch position Ventilator blower levels for LED indicator
1234Green Green/
Yellow
Yellow Yellow/
Red
Red
Ventilator control
with blower levels
AEROMAT VT RS
AEROMAT VT WRG
OFF OFF OFF OFF Off I I II II
ON OFF OFF OFF Off I II II II
OFF ON OFF OFF I I II II II
ON ON OFF OFF Off Off Off I II
Ventilator control with blower
"On"/"Off"
AEROVITAL
AEROLIFE
AEROPLUS
AEROPAC SN
AEROVITAL ambience
OFF OFF OFF ON Off On On On On
ON OFF OFF ON Off Off On On On
OFF ON OFF ON Off Off Off On On
ON ON OFF ON Off Off Off Off On
AEROMAT
100/150 Type DK
(closing flap
"Open"/"Closed")
OFF OFF OFF ON Closed Open Open Open Open
ON OFF OFF ON Closed Closed Open Open Open
OFF ON OFF ON Closed Closed Closed Open Open
ON ON OFF ON Closed Closed Closed Closed Open

SENSOAIR Installation and operating instructions
14 03.2017
Motor-driven window drives
DIP switch position Window position for LED indicator
1234Green Green/
Yellow
Yellow Yellow/
Red
Red
Motorised handle MH10
DRIVE axxent DK
OFF OFF ON ON Closed Open Open Open Open
ON OFF ON ON Closed Closed Open Open Open
OFF ON ON ON Closed Closed Closed Open Open
ON ON ON ON Closed Closed Closed Closed Open
Motion chain drives
OFF OFF OFF ON Closed Open Open Open Open
ON OFF OFF ON Closed Closed Open Open Open
OFF ON OFF ON Closed Closed Closed Open Open
ON ON OFF ON Closed Closed Closed Closed Open
Function test for connected devices (automatic)
1. Switch on power supply
2. Relay 1 switches on after 30 seconds
3. Relay 2 switches on after 60 seconds
4. Both relays switch off after 90 seconds and the test is complete
7.2 SENSOAIR smart
The SENSOAIR smart can be controlled by a tablet or smartphone.
Please follow the enclosed quick start instructions (H47.MOTS005EN).
Overview of the device functions
• Indicator of air quality
• Turning the LED indicator On/Off
• Coupling of SIEGENIA smart devices:
- AEROPAC SN smart
- AEROMAT VT RS smart
- AEROMAT VT WRG 1000 smart
- AEROMAT VT WRG 1100 smart
- DRIVE axxent DK smart

Installation and operating instructions SENSOAIR
03.2017 15
8. Commissioning
8.1 Automatic calibration of the CO2and VOC sensors
• The sensors are calibrated automatically as soon as the SENSOAIR is connected to the power
supply (and also following a power failure).
• The LED makes 1x long green flash during the calibration.
• The calibration is completed after approx. 30 min. The LED is then permanently illuminated in green.
Requirements for a faultless calibration
• The room must be well aired before the calibration.
• The room temperature must be between 5°C and 40°C.
• There should be no persons or animals in the room.
9. Care and maintenance
Electrically operated unit.
Risk of fatal injury from electric shock or fire.
To prevent personal injury or damage to property, always comply with the
following instructions:
›Pull the mains plug out of the socket prior to every cleaning process or maintenance work.
Never pull at the cable to disconnect the device from the power supply.
›For all devices with a fixed connection to the 230 V AC mains power supply, switch off all poles
of the feeder. The fuses may need to be removed.
9.1 Cleaning
Important: When cleaning the SENSOAIR, do not allow liquids to get inside the unit.
• Never use cleaning agents that are aggressive or contain solvents, or sharp-edged objects, as these
may damage the surfaces of the casing.
• Never clean the unit with a high-pressure cleaner or steam-jet cleaner.
• Clean the SENSOAIR with a cloth moistened with a mild soap solution or cleaning agent.

SENSOAIR Installation and operating instructions
16 03.2017
10. Rectification of malfunctions
In case of a malfunction, do not open the device or try to repair it under any circumstances.
If the problem is not listed in the table below, please contact your installation firm or SIEGENIA
directly: Tel. +49 271 3931-0
Problem Possible cause Solution
LED 1x long green
flash per second Automatic calibration active No help required (for further informati-
on see page Page 15)
LED 2x short green
flashes per second The CO2sensor is defective Contact installation company
LED 1x short red flash
per second The VOC sensor is defective Contact installation company
SENSOAIR smart
does not respond to
smartphones/tablets
No WLAN connection to the
router of the home network
Restart WLAN router of the home
network
No WLAN connection to the
smartphone/tablet Restart smartphone/tablet
No WLAN connection to the
SENSOAIR smart
Reset SENSOAIR smart:
1. Using a pointed object, press button
3 times briefly in succession
2. Hold button 1x (for approx. 4
seconds) directly on the connection
The SENSOAIR smart will then return to
the default setting.
10.1 SIEGENIA Comfort App
You will find detailed operating information as well as information on how to rectify
disturbances on the SIEGENIA Smarthome Internet page:
https//smarthome.siegenia.com

Installation and operating instructions SENSOAIR
03.2017 17
11. Technical specifications
• The concentration of CO2and VOCs in the air is measured in parts per million (ppm). The CO2
concentration outdoors is approx. 350 ppm. A level of above approx. 800 ppm negatively impacts
our well-being.
• If the CO2content or the VOC concentration exceeds the following values, SENSOAIR indicates this
using the LED traffic light and connected devices are activated.
• The concentration of CO2in a room depends on the number of people in the room, the length of time
that they spend in that room, the volume of the room and the air change rate.
• For example, a 60 m³ room that contains two people and has an air change rate of 1 will reach a
CO2concentration of 900 ppm.
• Without ventilation, the concentration in the room would increase to 1,500 ppm after two hours and
2,500 ppm after five hours.
• The VOC sensor has a high level of cross sensitivity. For example, it reacts to ethanol, carbon monoxi-
de, methane, butane and cigarette smoke. The concentrations of the individual gases are measured
in the range from 1 - 100 ppm and combined with the CO2values to produce the reference value for
the ventilator control.
CO2concentration
LED indicator CO2Outcome
2x brief red flashes 2,500 ppm Air quality is very poor
1x long red flash 2,000 ppm and
above
Air quality is very poor
Continuously red 1,500 ppm Maximum permissible value for offices and
classrooms
Yellow/Red 1,000 ppm Maximum permissible value for living spaces
Continuously yellow 800 ppm Air is perceived as being poor
Green/Yellow 600 ppm Air quality is becoming worse
Continuously green 350 ppm Clean, fresh air
Measuring range of sensors Approx. 350 ppm - 3,000 ppm (CO2and VOC)
Service life of sensors Approx. 10 years
Permissible room temperature 5°C to 40°C
Supply voltage 230V AC / 24V DC (depending on the device)
Power consumption 1.5W
Device control (optional) Air quality values can be adjusted with a DIP
switch
Protection class II, all-insulated
Protection class IP 4X
Casing Surface-mounted, ASA, RAL 9003 signal white
Dimensions (W x H x D) 154mm x 98mm x 39mm

SENSOAIR Installation and operating instructions
18 03.2017
12. Information concerning product liability
12.1 Intended use
Any use of this product that is not in accordance with its correct use, or any adaptation of or
modification to the product and its associated components for which the express consent of
SIEGENIA has not been obtained, is strictly prohibited. SIEGENIA accepts no liability whatsoever
for any material losses or injury to people caused by failure to comply with this stipulation.
12.2 Warranty
This product is guaranteed for a period of two years – subject to correct installation and proper use
– in accordance with the provisions of the law. As part of our ongoing improvements, we reserve the
right to make changes to individual components or the device as a whole. Consequential losses
resulting from defects are excluded from the warranty within the limits of the law. The warranty shall
become void if modifications that are not authorised by us or have not been described in this
documentation are made to the product and/or individual components or if the product and/or
individual components is/are dismantled or partly dismantled.
12.3 Disclaimer of liability
The product and its components are subject to stringent quality controls. As a result, they function
reliably and safely when used correctly.
Our liability for consequential losses and/or claims for damages is excluded, except in the case of
wilful misconduct or gross negligence, or where we are responsible for injury to life, physical injury
or damage to health. Strict liability under the German Product Liability Act (Produkthaftungsgesetz)
remains unaffected. Liability for the culpable violation of significant contractual obligations also
remains unaffected; liability in this case is limited to losses that are specific to the contract and that
could have been foreseen. The above regulations do not imply a change in the burden of proof to
the detriment of the consumer.
12.4 Environmental protection
Although our products do not fall within the scope of the German Electrical and Electronic
Equipment Act, SIEGENIA will continue to meet the requirements of this Act and will endeavour to
completely eliminate the use of substances that are hazardous to the environment as soon as this
becomes technically feasible.
Electrical products should not be disposed of as household waste.
13. Feedback on documentation
We welcome your comments and suggestions on how to improve our documentation. Please email

Installation and operating instructions SENSOAIR
03.2017 19
14. EU Declaration of Conformity with regard to CE marking
For our product SENSOAIR, we confirm that the general safety of the defined product, in accordan-
ce with Directive 2001/95/EC, is compliant with the relevant protection requirements which are laid
down in the Council Directives about electrical and electronic products.
The following listed test standards, which are harmonised in the relevant directives, have been
employed for the evaluation:
a) 2014/30/EC EMC Directive
EN 55014-1:2006+A1:2009+A2:2011
EN 55014-2:1997+A1:2001+A2:2008
EN 61000-3-2:2014
EN 61000-3-3:2013
b) 2014/35/EC Low voltage directive
EN 60730-1:2011
EN 62233:2008
c) 2014/53/EC RED Directive
c1) Electromagnetic compatibility
EN 301489-1, V.1.9.2
EN 301 489-17, V.2.2.1
EN 61000-3-2:2014
EN 61000-3-3:2013
c2) Electrical safety - Establishment of information technology
EN 60950-1:2006+A11:2009+A12:2011+A1:2010+A2:2013
c3) Safety of persons in electromagnetic fields (10 MHz to 300 GHz)
EN 62479:2010
c4) Funkspektrumangelegenheiten - Datenübertragungsgeräte im 2,4- GHz-ISM-Band
EN 300 328 V1.9.1
d) 2011/65/EU RoHs
EN 50581:2012 Technical documentation on the evaluation of electrical and electronic
devices with reference to the restriction of hazardous substances
This declaration is responsible for the manufacturers / importers based in the European Union
submitted by:
SIEGENIA-AUBI KG
Hardware and ventilation technology
Duisburger Straße 8
57234 Wilnsdorf
Siegen, 2017-03-14

H39.SENS005EN/0
Contact your dealer:
Head O ce:
Industriestraße 1–3
57234 Wilnsdorf
GERMANY
Phone: +49 271 3931-0
Telefax: +49 271 3931-333
www.siegenia.com
SIEGENIA worldwide:
Austria Phone: +43 6225 8301
Belarus Phone: +375 17 3143988
Benelux Phone: +31 85 4861080
China Phone: +86 316 5998198
France Phone: +33 3 89618131
Germany Phone: +49 271 39310
Great Britain Phone: +44 2476 622000
Hungary Phone: +36 76 500810
Italy Phone: +39 02 9353601
Poland Phone: +48 77 4477700
Russia Phone: +7 495 7211762
South Korea Phone: +82 31 7985590
Switzerland Phone: +41 33 3461010
Turkey Phone: +90 216 5934151
Ukraine Phone: +380 44 4637979
You can fi nd address details for our
international sites at: www.siegenia.com