1. Product description
This transponder is supplied either as an SAT 12 with
a housing or an SMT 12 without the housing.
2. Supply package
The SAT 12 package contains the following :
- One SAT 12 Housing (only SAT 12).
- One SMT 12 transponder (board).
- 8 terminating resistors (4.7 kOhm).
- One set (4 off) of mounting studs (only SMT 12).
- One SLT 12 language kit complete with :
- Installation instructions.
- One Wiring diagram.
- One cable with socket connector for external
tamper contact (only SMT 12).
3. Mounting instructions
The SAT 12 and SMT 12 are designed for mounting
in dry indoor rooms. They must not be exposed to
either dripping or splashing water. The SMT 12 is
designed for installation either in an power supply
unit or a suitable flush-type box.
3.1 Open housing (fig. 1)
1 - Slacken the retaining screw Q.
2 - Remove the cover W.
3.2 Product overview (fig. 2)
Housing (SAT 12 only) with the following:
- Mounting holes W.
- Holes or knockouts Q,Efor cables.
- Eye Rfor sealing.
- Locking tab Tto hold the circuit board.
- SMT 12 circuit board Y.
- Knockout Ufor the back tamper contact screw.
3.2.1 SMT 12 circuit board (fig. 3)
- Wire jumpers Qfor programming glass break
alarm inputs.
- Plug connector Wfor external tamper contact,
connected in parallel to the tamper contact E.
- Tamper contact of SAT 12 housing E.
- Four inputs R.
- Two «open collector» outputs T.
- E-Bus connection Y.
- Address key U.
- LED Iflash if the E-Bus communication is correct
3.3 Fit SAT 12 housing (fig. 4)
1 - If necessary, break out the knockouts for
cables (A).
2 - Insert cables.
3 - Secure the base using 2 screws (B).
3.4 Fit SMT 12 circuit board
1 - Engage the mounting studs in the holes (fig. 5A).
2 - Fit circuit board (fig. 5B).
SAT 12/SMT 12
Installation instructions
s
SLT 12 UK
20 800 771.0-010
Q
W
U
Y
T
R
E
W
Q
Q
R
T
Y
U
I
W
E
B4+ B3
E-Bus
Emply
B2 B1- NC NC
O2 O1 Z4 Z3 Z2 Z1
123456789
Fig. 6
Fig. 7
The right to make technical changes to the described equipment without
prior notice is reserved.
4. Wiring
The terminals are shown in fig. 3 and on the wiring
diagram glued to the inside of the cover.
4.1 E-Bus (fig. 6)
Cable type 24 AWG 7 x Ø 0,2 mm is recommended.
The total length of the E-Bus cable must not exceed
500 m. The E-Bus must be connected to the central
control unit (B1-, B2, B3, B4+). It may be routed in
parallel to other accessories. If shielded cable is used,
all the shields must be connected at one point, e.g. at
an NC terminal.
4.2 Tamper contact
If the SMT 12 circuit board is not fitted in the SAT
12 housing, the plug connector (fig. 3 W) must be
connected to an external tamper contact or be short-
circuited. Use the socket connector provided to connect
to an external tamper contact.
4.3 Inputs (fig. 7)
All inputs can be operated in modes 1 to 4 and 6 to
7 (fig. 7). Inputs Z1 to Z2 can also be operated with
glass break alarms. To do this, the relevant switches
SW1 to SW2 must be closed and one terminal of each
glass break sensor connected to one of outputs O1 to
O2, which must be programmed for «Latching sensor
reset». When wiring fire detectors, any trouble output
present can be looped directly into the line. For fire
detectors where the power has to be disconnected
to reset the alarm, the negative can be connected
via an output which is programmed as a «Latching
sensor reset» output.
The emergency exit has to be wired like mode 6. A
short circuit of the input will reset the corresponding
output.
5. Close and seal the housing
1 - Engage the cover in the retainer at the top (fig. 1).
2 - Close the cover and tighten the retaining screw
(fig. 1).
3 - Use eye (fig. 2 R) for sealing.
6.Technical data
Supply from the E-Bus
Power consumption min. 6 mA
Power consumption max. 19 mA
2 outputs «open collector» 12 V, 150 mA
4 inputs Programmable
Terminating resistors 4.7 kOhm
Operating temperature -10° C to +55° C
Housing ABS
Dimensions in mm, SAT 12 H 86 x W 135 x D
27 Safety class, SAT 12 IP 30
Environmental class, SAT 12 II
Weight, SAT 12 130 g
Dimensions in mm, SMT 12 H 52 x W 91 x D 20
Weight, SMT 12 50 g
E-Bus from the
central control unit
E-Bus to other
accessories
B4+
B3
B2
B1-
5. Glass break sensors
Z
O
4k7
Z1
Z2 SW 1
SW 2
4k7
4k7 Z
Tamper
Alarm
Input modes
1. Normally open contact
2. Normally closed contact
4. Alarm & tamper monitored
6. Emergency exit
7. Fire input
4k7
4k7 Z
Tamper
Reset
Alarm
Z
4k7
Alarm
Trouble
ClosedInput OpenSwitch
To connect a maximum
of 20 glass break sensors
All other modes
4k7 Z
Z
Z
3. Normally closed contact
monitored

This manual suits for next models

1

Other Siemens Marine Radio manuals

Siemens SIMATIC RF645T Administrator guide

Siemens

Siemens SIMATIC RF645T Administrator guide

Siemens SIMATIC RTLS4460T User manual

Siemens

Siemens SIMATIC RTLS4460T User manual

Siemens SIMATIC RF610T User guide

Siemens

Siemens SIMATIC RF610T User guide

Siemens SIMATIC RTLS4084T User manual

Siemens

Siemens SIMATIC RTLS4084T User manual

Siemens SIMATIC RTLS4060T User manual

Siemens

Siemens SIMATIC RTLS4060T User manual

Siemens SIMATIC RTLS4030T Application guide

Siemens

Siemens SIMATIC RTLS4030T Application guide

Siemens SIMATIC RTLS4060T User manual

Siemens

Siemens SIMATIC RTLS4060T User manual

Siemens SIMATIC RTLS4083T Application guide

Siemens

Siemens SIMATIC RTLS4083T Application guide

Siemens FDCI183 User manual

Siemens

Siemens FDCI183 User manual

Siemens SIMATIC RTLS4083T User manual

Siemens

Siemens SIMATIC RTLS4083T User manual

Popular Marine Radio manuals by other brands

Cobra Marine MR HH350 FLT EU Specifications

Cobra Marine

Cobra Marine MR HH350 FLT EU Specifications

West Marine VHF 480 owner's manual

West Marine

West Marine VHF 480 owner's manual

Chronelec Protime LS installation guide

Chronelec

Chronelec Protime LS installation guide

Garmin GTX 335 Series pilot's guide

Garmin

Garmin GTX 335 Series pilot's guide

Garmin GTX 327 pilot's guide

Garmin

Garmin GTX 327 pilot's guide

West Marine VHF 150 owner's manual

West Marine

West Marine VHF 150 owner's manual

Garrecht Avionik VT-01 installation manual

Garrecht Avionik

Garrecht Avionik VT-01 installation manual

SANDIA aerospace STX 165 installation manual

SANDIA aerospace

SANDIA aerospace STX 165 installation manual

Kongsberg cNODE MiniS 1.11-50V Ti instruction manual

Kongsberg

Kongsberg cNODE MiniS 1.11-50V Ti instruction manual

Appareo Systems Stratus ES installation instructions

Appareo Systems

Appareo Systems Stratus ES installation instructions

Cobra Marine MR HH475 FLOAT BT owner's manual

Cobra Marine

Cobra Marine MR HH475 FLOAT BT owner's manual

West Marine VHF600 user guide

West Marine

West Marine VHF600 user guide

De Haardt XTRA.CDI user manual

De Haardt

De Haardt XTRA.CDI user manual

Rhotheta RT-1000 user manual

Rhotheta

Rhotheta RT-1000 user manual

Garmin 3X5/G1000 Series pilot's guide

Garmin

Garmin 3X5/G1000 Series pilot's guide

NorthStar Explorer 710 VHF Operation and installation manual

NorthStar

NorthStar Explorer 710 VHF Operation and installation manual

Uniden HH985 user guide

Uniden

Uniden HH985 user guide

Cobra Marine MR HH475 FLT BT owner's manual

Cobra Marine

Cobra Marine MR HH475 FLT BT owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.