Siemens SIMATIC RTLS4460T User manual

Siemens AG
Digi
tal Industries
Postfach 48 48
90026 NÜRNBERG
GERMANY
Document order number: C79000-G8976-C522-04
Ⓟ
05/2021 Subject to change
Copyright © Siemens AG 2021.
All rights reserved
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.

SIMATIC RTLS4460T
Operating Instructions, 05/2021, C79000-G8976-C522-04 3
Table of contents
1 Introduction ........................................................................................................................................... 5
2 Device description ................................................................................................................................. 9
2.1 Characteristics ..................................................................................................................... 9
2.2 Order data RTLS4460T ......................................................................................................... 9
2.3 Pin assignment .................................................................................................................. 10
2.4 LED status indicator ........................................................................................................... 12
2.5 Dimension drawing............................................................................................................ 13
3 Installation & Operation ...................................................................................................................... 15
3.1 Notes on installation.......................................................................................................... 15
4 Technical specifications....................................................................................................................... 17
5 Approvals............................................................................................................................................. 19

Table of contents
SIMATIC RTLS4460T
4Operating Instructions, 05/2021, C79000-G8976-C522-04

SIMATIC RTLS4460T
Operating Instructions, 05/2021, C79000-G8976-C522-04 5
Introduction
1
Purpose of the Operating Instructions
These operating instructions support you when installing and connecting up the SIMATIC
RTLS4460T device.
The configuration via the SIMATIC RTLS Locating Manager and the integration of the devices
in a network are not described in these operating instructions.
Validity of the Operating Instructions
These operating instructions apply to the following device:
•RTLS4460T (Article number: 6GT2700-6CE02)
Further documentation
The system manual "Commissioning SIMATIC RTLS" provides information on other SIMATIC
RTLS products that you can operate together with the devices in this product line in an
Industrial Ethernet network.
You can find the system manual at the following link:
(https://support.industry.siemens.com/cs/us/en/ps/25277)
Trademarks
The following and possibly other names not identified by the registered trademark sign ®are
registered trademarks of Siemens AG:
SIMATIC RTLS

Introduction
SIMATIC RTLS4460T
6Operating Instructions, 05/2021, C79000-G8976-C522-04
Industry Online Support
In addition to the product documentation, the comprehensive online information platform of
Siemens Industry Online Support offers support at the following Internet address:
(https://support.industry.siemens.com/cs/start?lc=en-US)
Apart from news, there you will also find:
•Project information: Manuals, FAQs, downloads, application examples etc.
•Contacts, Technical Forum
•The option submitting a support query: (https://support.industry.siemens.com/My/us/en/)
•Our service offer:
Right across our products and systems, we provide numerous services that support you in
every phase of the life of your machine or system - from planning and implementation to
commissioning, through to maintenance and modernization.
You will find contact information on the Internet at the following address:
(https://www.automation.siemens.com/aspa_app/?ci=yes&lang=en)
SITRAIN - Training for Industry
The training offer includes more than 300 courses on basic topics, extended knowledge and
special knowledge as well as advanced training for individual sectors - available at more than
130 locations. Courses can also be organized individually and held locally at your location.
You will find detailed information on the training curriculum and how to contact our
customer consultants at the following Internet address:
(https://new.siemens.com/global/en/products/services/industry/sitrain/personal.html)
Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines, and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens’ products and solutions form one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems,
machines and networks. These systems, machines and components should only be
connected to the enterprise network or the Internet if and only to the extent necessary and
with appropriate security measures (firewalls and/or network segmentation) in place.
You can find more information on protective measures in the area of industrial security by
visiting:
https://www.siemens.com/industrialsecurity (http://www.siemens.com/industrialsecurity).
Siemens’ products and solutions undergo continuous development to make them more
secure. Siemens strongly recommends performing product updates as soon as they are
available and using only the latest product versions. Use of product versions that are no
longer supported, and failure to apply latest updates may increase customer’s exposure to
cyber threats.

Introduction
SIMATIC RTLS4460T
Operating Instructions, 05/2021, C79000-G8976-C522-04 7
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed under
https://www.siemens.com/industrialsecurity (http://www.siemens.com/industrialsecurity).
Security recommendations
General
Note the following security recommendations to prevent unauthorized access:
•Keep the firmware up to date. Check regularly for security updates for the device. You can
find information on this at the Industrial Security
(https://new.siemens.com/global/en/company/topic-areas/future-of-
manufacturing/industrial-security.html) website.
•Inform yourself regularly about security recommendations published by Siemens
ProductCERT (https://new.siemens.com/global/en/produkte/services/cert.html).
•Evaluate your plant as a whole in terms of security. Use a cell protection concept with
suitable products.
•This product requires an additional security concept to prevent unauthorized access.
•Ensure that the radio frequencies are not used for other purposes and are not affected by
other interfering signals. This should be ensured within the operating range of the
localization system.
•Interference in the frequency band used can impair the system and, in extreme cases, lead
to localization failure.
Physical access
•Restrict physical access to the device to qualified personnel.
•Disable unused physical interfaces of the device. Unused interfaces could be used to gain
access to the operating site.
Recycling and disposal
The products are low in harmful substances, can be recycled and meet the requirements of
the Directive 2012/19/EU for disposal of waste electrical and electronic equipment (WEEE).
Do not dispose of the products at public disposal sites.
For environmentally compliant recycling and disposal of your electronic waste, please contact
a company certified for the disposal of electronic waste or your Siemens representative.
Note the different national regulations.

Introduction
SIMATIC RTLS4460T
8Operating Instructions, 05/2021, C79000-G8976-C522-04

SIMATIC RTLS4460T
Operating Instructions, 05/2021, C79000-G8976-C522-04 9
Device description
2
2.1 Characteristics
SIMATIC RTLS4460T
Characteristics
Design
①Status indicators (LEDs)
②Antenna connector for RP SMA antenna
③Connector for supply voltage, CAN bus and
digital inputs and outputs
General
The transponder is the mobile device for locali-
zation in the RTLS localization system. It sends
position data to gateways which transmit the
data to the Locating Manager server.
Area of application
The transponder is suitable for installation in
vehicles and other devices and is connected to
the supply voltage there.
2.2 Order data RTLS4460T
Table 2- 1 Order data RTLS4460T
Article number
SIMATIC RTLS4460T
CE/FCC/ISED
6GT2700-6CE02
Table 2- 2 Accessories order data (not included in scope of delivery)
Article number
Connector with crimp contacts, 16-pin
6GT2790-0BB00
Antenna with FME-M connector
6GT2706-0CA00
Antenna ANT896-6MH, N-Connector
6GK5896-6MH00-0AA0
Antenna connecting cable FME-F / RP-SMA-M
2 m
6GT2791-6AH20
3 m
6GT2791-6AH30
Antenna connecting cable N-Connect / RP-SMA-M
1 m
6XV1875-5TH10
2 m
6XV1875-5TH20
3 m
6XV1875-5TH30
5 m
6XV1875-5TH50

Device description
2.3 Pin assignment
SIMATIC RTLS4460T
10 Operating Instructions, 05/2021, C79000-G8976-C522-04
2.3 Pin assignment
X1 - Connector for supply voltage, CAN bus and digital inputs and outputs
16-pin plug-in connector WR-MPC4 Würth-Elektronik
For single wires of 0.33 mm2to 1.31 mm2
Pin
Description
1
not applicable
2
Digital input 7
3
Digital input 5
4
Digital input 3
5
Digital input 1
6
CAN high
7
Digital output 1
8
24 V DC
Connector
Description
9
not applicable
10
Digital input 8
11
Digital input 6
12
Digital input 4
13
Digital input 2
14
CAN low
15
Digital output 2
16
GND

Device description
2.3 Pin assignment
SIMATIC RTLS4460T
Operating Instructions, 05/2021, C79000-G8976-C522-04 11
Digital output
The digital output can switch resistive, capacitive and inductive loads. The current is
automatically limited to these functions. Observe the value for the maximum current in
section "Technical specifications (Page 17)". A freewheeling diode DVis required for
inductivities.
Digital input
The device has 8 digital inputs, 1 to 8. Each has a range from 0 to 24 V with an impedance of
4.7 kOhm.
Input 8 is different in that the impedance can be switched off. The input impedance is
110 kOhm in this case.
ANT1 - Antenna - RP-SMA plug-in connector
Use only the accessories specified in section "Order data RTLS4460T (Page 9)".

Device description
2.4 LED status indicator
SIMATIC RTLS4460T
12 Operating Instructions, 05/2021, C79000-G8976-C522-04
2.4 LED status indicator
The operating states of the transponder are indicated by the LEDs. The states can be off , on
and flashing .
RADIO LED (D1)
Meaning
Off when the transponder is not transferring any data via wireless
Lights up for 1 second on system start
Flashes yellow once per second if data was transferred in the previous second
RUN LED (D2)
Meaning
Off when the transponder is inactive
Lights up for 1 second on system start
Flashes green every 0.2 seconds after a watchdog reset
Flashes every three seconds when the device has not detected any movement
Lights up permanently when the device has detected movement
BUS LED (D3)
Meaning
Off when the transponder is not sending or receiving any data via the CAN bus
Lights up for 1 second on system start
Flashes yellow once per second if data was transferred via the CAN bus in the
previous second

Device description
2.5 Dimension drawing
SIMATIC RTLS4460T
Operating Instructions, 05/2021, C79000-G8976-C522-04 13
2.5 Dimension drawing
Figure 2-1 Dimension drawing SIMATIC RTLS4460T - All dimensions specified in millimeters

Device description
2.5 Dimension drawing
SIMATIC RTLS4460T
14 Operating Instructions, 05/2021, C79000-G8976-C522-04

SIMATIC RTLS4460T
Operating Instructions, 05/2021, C79000-G8976-C522-04 15
Installation & Operation
3
3.1 Notes on installation
Note
Before you install the devices, read this section carefully to ensure trouble
-free installation
and commissioning.
The devices can only be used in conjunction with the RTLS localization system.
The device is intended for installation in a vehicle. Installation is to be performed by qualified
and trained users according to the operating instructions. In addition, installation must take
place in accordance with the respective instructions for the installation of electrical systems
and utilities.
Note the specifications in the section "Technical specifications (Page 17)" during installation
and operation. Protect the device against moisture.
Make sure that the ambient temperature does not exceed 70 °C and that the device is not
installed in a location where it is exposed to direct sunlight.
Connection of the cables
Make sure that the wiring is correct before you start up the device.
Connection of the antenna
Connect the antenna to the RP SMA connector (ANT1). The device must not be operated
without an antenna. The device must be turned off or disconnected from the power to
change or remove the antenna.
Supply voltage
When the supply voltage is connected, all LEDs light up for 1 second.
Check whether the rated voltage of the power supply corresponds to the values in the section
"Technical specifications (Page 17)".

Installation & Operation
3.1 Notes on installation
SIMATIC RTLS4460T
16 Operating Instructions, 05/2021, C79000-G8976-C522-04

SIMATIC RTLS4460T
Operating Instructions, 05/2021, C79000-G8976-C522-04 17
Technical specifications
4
Table 4- 1 Technical specifications of the transponder RTLS4460T
6GT2700-6CE02
Product name
SIMATIC RTLS4460T
Wireless frequencies
Wireless method
IEEE 802.15.4a Chirp Spread Spectrum (CSS)
Transmission speed
1 Mbit/s
Frequency range
2400 ... 2480 MHz
Transmit power
Maximum 100 mW (configurable)
Range
Maximum 500 m
Accuracy of the localization (typical)
1.5 m
Chirp bandwidth
80 MHz
Supply voltage, power consumption
Supply voltage
DC 10 V ... 30 V
Rated voltage
DC 24 V
Power consumption
Max. 1.6 W / 0.06 A
Digital inputs
Input voltage
DC 0 ... 24 V
Input impedance
4.7 Kilohm
Input 8 selectable 4.7 Kilohm or 110 Kilohm
Digital outputs
Output
High-side switch →Connect to input voltage
Output current
Maximum 250 mA, short-circuit proof
Output voltage
0 V or supply voltage
Load
Resistive, capacitive or inductive
Permitted ambient conditions
Ambient temperature
•During operation
•During transport
•During storage
•-40 ... +70 °C
•-40 ... +70 °C
•-40 ... +70 °C

Technical specifications
SIMATIC RTLS4460T
18 Operating Instructions, 05/2021, C79000-G8976-C522-04
6GT2700-6CE02
Design, dimensions, weights and connectors
Dimensions (L x W x H)
138 x 62 x 31 mm
Weight
125 g
Degree of protection
IP20
Enclosure
Plastic housing
Color
Gray
Method of securing
4 mounting holes for M4 countersunk head screws and 1
oblong hole each on the front sides
Plug-in connector (X1)
16-pin plug-in connector WR-MPC4 Würth-Elektronik, for
single wires from 0.33 mm² to 1.31mm²
Antenna connector
RP-SMA
Fuses
Mini blade-type fuse, 2 A

SIMATIC RTLS4460T
Operating Instructions, 05/2021, C79000-G8976-C522-04 19
Approvals
5
Note
The specified approvals apply only when the corresponding mark is printed on the product.
You can check which of the following approvals have been granted for your product by the
markings on the type plate.
You can find the current EU Declaration of Conformity for these products on the Internet at
Siemens Industry Online Support.
Link:
(https://support.industry.siemens.com/cs/products?dtp=Certificate&mfn=ps&pnid=14970&lc=
en-US)
The products described in this document meet the requirements of the following EU
directives:
•RoHS Directive 2011/65/EU
Directive of the European Parliament and of the Council of 8 June 2011 on the restriction
of the use of certain hazardous substances in electrical and electronic equipment, official
journal of the EU L174, 1 July 2011, pages 88-110
•Radio Equipment Directive 2014/53/EU (RED)
Directive of the European Parliament and of the Council of 16 April 2014 on the
harmonization of the laws of the member states relating to placing radio equipment on
the market; official journal of the EU L153, 22 May 2014, pages 62-106
RoHS directive (restriction of the use of certain hazardous substances)
The products described in these operating instructions meet the requirements of the EU
directive 2011/65/EU on the restriction of the use of certain hazardous substances in
electrical and electronic equipment.
Applied standard:
•EN 50581
Technical documentation for the assessment of electrical and electronic products with
respect to restriction of hazardous substances
The products described in this document meet the requirements of the applied standards:

Approvals
SIMATIC RTLS4460T
20 Operating Instructions, 05/2021, C79000-G8976-C522-04
Article 3 (1) a) Protection of health and safety
•EN 62368-1
Equipment for audio/video, information and communication technology – Part 1: Safety
requirements
•EN 62311
Assessment of electronic and electrical equipment related to human exposure restrictions
in electromagnetic fields (0 Hz - 300 GHz)
The products described in these operating instructions meet the requirements of EU directive
2014/30/EU "Electromagnetic Compatibility" according to the designated standards for the
following areas of application.
Article 3 (1) b) EMC
•ETSI EN 301 489-1
Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic
compatibility for radio equipment and services - Part 1: Common technical requirements
•ETSI EN 301 489-17
Electromagnetic compatibility and radio spectrum matters (ERM) - Electromagnetic
compatibility for radio equipment and services - Part 17:
Specific conditions for broadband data transmission systems
•EN 50121-3-2
Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
•EN 55011
Industrial, scientific and medical equipment - Radio-frequency disturbance
characteristics – Limits and methods of measurement
•EN 55032 Class A, Class B
Electromagnetic compatibility of multimedia equipment – Emission requirements
•EN 55035
Electromagnetic compatibility of multimedia equipment - Immunity requirements
•EN 61000-6-1
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for
residential, commercial and light-industrial environments
•EN 61000-6-2
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial
environments
•EN 61000-6-3
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for
residential, commercial and light-industrial environments
•EN 61000-6-4
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for
industrial environments
This manual suits for next models
1
Table of contents
Other Siemens Marine Radio manuals

Siemens
Siemens SIMATIC RTLS4084T User manual

Siemens
Siemens FDCI183 User manual

Siemens
Siemens SIMATIC RF610T User guide

Siemens
Siemens SIMATIC RTLS4060T User manual

Siemens
Siemens SIMATIC RTLS4030T Application guide

Siemens
Siemens SIMATIC RTLS4060T User manual

Siemens
Siemens SIMATIC RTLS4083T Application guide

Siemens
Siemens SAT 12 User manual

Siemens
Siemens SIMATIC RTLS4083T User manual

Siemens
Siemens SIMATIC RF645T Administrator guide