580.042b GB 181004
Description
DigiFloor is an electronic thermostat forthe regulation of
floor heating. Mounting is done via a connection box.The
thermostat is controlled wirelessly by the DigiHeat control
unit. Time base for switching of load is 20 minutes.
DigiFloor must be installed by an authorized electrician.
If the floor sensor is not connected, the thermostat will use
an internal air sensor for the regulation of room temperature
(5-30°C). When the floor sensor is connected switching
times are operational according to floortemperature.When
the floorsensor is used the setpoint temperature should be
considered as a guide figure only. Start off with a setpoint
temperature of 20°C and adjust setpoint temperature until
floor temperature is at your comfort level. NOTE! It takes
hours for the floor temperature to stabilize.
It is possible to use both the internal air sensor and floor
sensor. The internalair sensor will regulate room
temperature, while the floor sensor will limit the floor
temperature to a maximum of 27°C. See paragraph sensor
alternatives for details.
Installation of DigiFloor
Remove the control knob by pulling it towards you. (fig.1).
Remove the bigger of the two screws below the control
knob (fig. 2).
Fig. 1
Screw
The frontcover and the frame can now be removed. Turn
the thermostat and complete the necessary connections
(fig. 3).
Heat element
Max 16A
Mains
230V +/- 10%
Floor
sensor
31 2
N
230V~4VA
54
16A
6
L
Fig. 2
The thermostat is then mounted inside the connection box.
Screwhole
Fig. 4
TOP
Refit the frame and the front cover. Ensure that the arrow
marked ”TOP” is pointing upwards as shown in fig. 4.
Fasten thescrew and put the control knob back in position.
Note! DigiFloor is not equipped with a 2-pole switch, and a
separateswitch must be mounted if required by the
particular installation.
Note! DigiFloor is not equipped with an earth terminal. Any
earth terminals from heat cable/mains must be connected
by separate earth connector.
Configuration of DigiFloor
(see also user instruction for DigiHeat)
First time configuration:
When installed for the first time the thermostat’s green OK-
lamp will blink. This ‘blinking’ indicates the thermostat is not
being programmed to receive information from the DigiHeat
control unit. Put DigiHeat in configurationmode (see
DigiHeatuser instructions). Press the push-button marked
on the thermostat. The OK-lamp will be lit and indicate that
the thermostat is ready to receive information from DigiHeat.
Reconfiguration:
Hold the push-button on the thermostat down for about 10
seconds until the OK-lamp starts to blink. Press the push-
button once. The OK-lamp will light after a few seconds
indicating the thermostat is once again configured. The
thermostat is now controlled by DigiHeat.
Normal operation
During normaloperation the thermostat is controlled by
DigiHeat. If the radio communication for some reason
should fail, the thermostat will start regulation, according to
its own temperature setting, after1 hour. The green OK-
lamp will start to blink. When the radio communication is re-
established the DigiHeat control unit will automatically take
over.
Installing the floor sensor
The floor sensor is put inside an installation tube embedded
in the concrete floor. The tubeshould be sealed and placed
as high in the concrete layer as possible. Only the enclosed
floor sensor must be used.
Placing of the thermostat with internal room sensor
The thermostat should beplaced on the wall 80 – 150 cm
from the floor, where air can pass without obstruction.
Direct sunlight should be avoided. The thermostat is not
approved for outdoor use.
LED indicators
Red ON: Heat element ON.
Red OFF: Heat element OFF.
Green ON: Thermostat is configured.
Green blinking: Unit not configured or radio signal is
missing.
Sensor alternatives
Floor sensor:
-Constant floor temperature, typically in rooms
where you walk barefooted.
-Floor sensor is automatically used when
connected.
-Note thata temperature setting of 5-30°C on
DigiHeat is equivalent to a floor temperature
setting of 5-40°C.
Internal sensor (air):
-Temperature setting on DigiHeat indicates
required room temperature (5-30°C ).
-The floortemperature willdepend on the room
temperature.
-Internal sensor should be used if floor sensor is
not possible.
Two sensors:
-The wire (2) as shown in fig.5 must be cut for the
thermostat to use both internalair sensor and floor
sensor. Use cutting pliers (1).
-Internal air sensor (or sensor in DigiHeat) is used
to regulate room temperature according to setpoint
temperature.
-Maximum floor temperature is limited to 27°C.
Typically for parquet or other temperature
sensitive floor types.
Local temperature control when DigiHeat is in comfort
mode ( )
In some situations it might be preferable to let the user
adjust the temperature on each heater, without having to do
adjustments on DigiHeat. The thermostat has abuilt-in
feature which willallow this. Normally each heater is
controlled 100% by DigiHeat, and localcontrolof
temperature is not possible. Note that only comfort
temperature ( ) can be controlled on each heater, while
setback ( ) and frost protection (OUT)is controlled by
DigiHeat as normal.
To activate this function, hold the button down while the
mains voltage is connected (fuse orswitch). Then let go of
the button when either the red or green light is blinking.
When the red light is blinking it indicates that no local
controlof comfort temperature is possible.When the green
light is blinking local control of comfort temperature is
possible. To toggle between these two modes, push the
button once. The choice of mode must be done during
10 seconds after activation.
The localcontrolof comfort temperature is well suited for
offices, kindergartens, and rental housing, where it is
preferred to let each user control the temperature during
comfort hours ( ). Note that when this function is activated
the comfort temperature displayed on DigiHeat will not have
any meaning.
During normal operation one push on the button allow
for 3 hours cancellation of setback or frost protection
temperature (for example during overtime hours).This
function is only possible for version v.1.03 (see product
label).
Room thermostat
The thermostat is prepared to receive measured
temperature from DigiHeat. In such case the measured
temperature from DigiHeat will be used to control the room
temperature, and the internal sensor is no longer in use.
See sensor alternatives. For DigiHeat 1 this will mean the
internal sensor in DigiHeat will control room temperature.
For DigiHeat 6+ the internal sensor can be activated for
zone A by setting P1=1 (see instruction DigiHeat 6+). Note
that DigiHeat must be placed in the temperature zone. This
function is only possible for version v.1.03 (see product
label).
Technical specifications
Operating voltage 230V +/- 10%
Maximum load 16A (resistive)
Isolation Class II
Protection IP30
Frequency 433,42 MHz
Temperature Internal sensor 5-30°C
Floor sensor 5-40°C
Temp. limit: Two sensors 27°C floor
OFF-switch No
Sensor type: NTC 100kΩ/ 25°C
Measure (l x w x h): 70 x 70 x 55mm
Building depth 32mm
El. number 54 683 88
DigiHeat room thermostat 16A
2NC9 840
GB
Fig.5

Other Siemens Thermostat manuals

Siemens EcoView 97-004 User manual

Siemens

Siemens EcoView 97-004 User manual

Siemens REV34 User manual

Siemens

Siemens REV34 User manual

Siemens Powers TH 192 S Owner's manual

Siemens

Siemens Powers TH 192 S Owner's manual

Siemens RDG400 User manual

Siemens

Siemens RDG400 User manual

Siemens TRG2 User manual

Siemens

Siemens TRG2 User manual

Siemens RDG200KN Operator's manual

Siemens

Siemens RDG200KN Operator's manual

Siemens RDE100 Series User manual

Siemens

Siemens RDE100 Series User manual

Siemens Powers TH 192 S User manual

Siemens

Siemens Powers TH 192 S User manual

Siemens RDF302/VB User manual

Siemens

Siemens RDF302/VB User manual

Siemens RDG400 User manual

Siemens

Siemens RDG400 User manual

Siemens Free Energy Band TH 193 HC Owner's manual

Siemens

Siemens Free Energy Band TH 193 HC Owner's manual

Siemens RDS120 User manual

Siemens

Siemens RDS120 User manual

Siemens RAA10C User manual

Siemens

Siemens RAA10C User manual

Siemens RDD100 Series User manual

Siemens

Siemens RDD100 Series User manual

Siemens RDG100 Series User manual

Siemens

Siemens RDG100 Series User manual

Siemens REV24 User manual

Siemens

Siemens REV24 User manual

Siemens KNX RDF600KN User manual

Siemens

Siemens KNX RDF600KN User manual

Siemens RDG100KN Operator's manual

Siemens

Siemens RDG100KN Operator's manual

Siemens RDG400KN User manual

Siemens

Siemens RDG400KN User manual

Siemens RDH100 User manual

Siemens

Siemens RDH100 User manual

Siemens RDD100 Series User manual

Siemens

Siemens RDD100 Series User manual

Siemens REV100 User manual

Siemens

Siemens REV100 User manual

Siemens ET 141 Owner's manual

Siemens

Siemens ET 141 Owner's manual

Siemens RDG140 User manual

Siemens

Siemens RDG140 User manual

Popular Thermostat manuals by other brands

Honeywell FTSE20 Mounting instructions

Honeywell

Honeywell FTSE20 Mounting instructions

Danfoss ECtemp 532 installation guide

Danfoss

Danfoss ECtemp 532 installation guide

AKO AKO-D1461 Series installation instructions

AKO

AKO AKO-D1461 Series installation instructions

Aube Technologies TH141-HC-28 user guide

Aube Technologies

Aube Technologies TH141-HC-28 user guide

Venstar T1119RF user manual

Venstar

Venstar T1119RF user manual

elv ETH eco user manual

elv

elv ETH eco user manual

Atag One Zone quick start guide

Atag

Atag One Zone quick start guide

Clas Ohlson TH810T-UK manual

Clas Ohlson

Clas Ohlson TH810T-UK manual

White Rodgers 1F95W-80 installation instructions

White Rodgers

White Rodgers 1F95W-80 installation instructions

Knauer Azura CT 2.1 instructions

Knauer

Knauer Azura CT 2.1 instructions

Bosch CR 20 RF quick start guide

Bosch

Bosch CR 20 RF quick start guide

Riello BeSMART quick start guide

Riello

Riello BeSMART quick start guide

MICRO-AIR EasyTouch RV Installation, Quick Start Guide and Operation Manual

MICRO-AIR

MICRO-AIR EasyTouch RV Installation, Quick Start Guide and Operation Manual

Conrad FHT80B-3 operating instructions

Conrad

Conrad FHT80B-3 operating instructions

Salus PH60 instruction manual

Salus

Salus PH60 instruction manual

Tech Controllers EU-R-8 PZ Plus user manual

Tech Controllers

Tech Controllers EU-R-8 PZ Plus user manual

Larson Electronics EXP-TSTAT-125.250-60.250F-0.25-V1-15L instruction manual

Larson Electronics

Larson Electronics EXP-TSTAT-125.250-60.250F-0.25-V1-15L instruction manual

Heatmiser Slimline-RF manual

Heatmiser

Heatmiser Slimline-RF manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.