manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Siemens
  6. •
  7. Thermostat
  8. •
  9. Siemens RDJ10 User manual

Siemens RDJ10 User manual

CE1N3071en
19.11.2007 Building Technologies
3071
Room temperature controller
with 24-hour time switch and
large LCD
RDJ10
For heating systems
•Operating modes: Automatic, Comfort, Energy Saving, and Frost Protection
•Large LCD
•Battery-powered: 2 x alkaline type AA batteries, 1.5 V
Use
The RDJ10 is used to control the room temperature in heating systems.
Typical applications:
•Homes
•Residential buildings
•Schools
•Offices
The controller is used together with the following equipment:
•Thermal valves or zone valves
•Combi boilers
•Gas or oil burners
•Fans
•Pumps
2/8
Siemens Room temperature controllers CE1N3071en
Building Technologies 19.11.2007
Functions
The controller acquires the room temperature with its integrated sensor.
Q14
T[°C]
ON
OFF W
SD
3031D01
T Room temperature
SD Switching differential
W Room temperature setpoint
L1 Output signal for heating
The RDJ10 provides room temperature control only.
Operating modes
The RDJ10 provides the following modes: Automatic, Comfort, Energy Saving and
Frost Protection.
Changeover between the operating modes is made by moving the operating mode
slider to the respective position.
When Automatic mode is active, symbol appears on the display.
The RDJ10 operates according to the selected 24-hour time program.
When Comfort mode is active, symbol appears on the display.
The RDJ10 controls to the temperature setpoint adjusted at .
This setpoint can be readjusted by setting the programming slider to .
When Energy Saving mode is active, symbol appears on the display.
The RDJ10 controls to the temperature setpoint adjusted at .
This setpoint can be readjusted by setting the programming slider to .
When Frost Protection is active, symbol appears on the display.
The RDJ10 controls to the fixed temperature setpoint for frost protection.
.
.
.
Function diagram
Temperature sensor
Automatic mode
Comfort mode
Energy Saving
mode
Frost Protection
L1
3/8
Siemens Room temperature controllers CE1N3071en
Building Technologies 19.11.2007
The digital display shows the actual room temperature, the ON / OFF times and the
symbol of the operating mode currently active. When the heating output is active, the
triangle symbol appears.
When taking out the batteries, the setpoints and the information required for operating
mode changeover are retained for maximum 2 minutes.
Ordering
When ordering, please give name and product number: Room temperature controller
RDJ10.
Valves and actuators are to be ordered as separate items.
Equipment combinations
Type of unit Product number Data sheet
Electromotoric actuator SFA21... 4863
Electrothermal actuator (for radiator valves) STA21... 4877
Electrothermal actuator (for small valves 2.5 mm) STP21... 4878
2- or 3-port zone valve MXI/MVI421… 4867
Electromotoric actuator for zone valves V..146.. SUA21 4830
Electric actuator SUA11/22 4832
Air damper actuator GDB… 4624
Air damper actuator GSD/GQD… 4606
Air damper actuator GXD… 4622
Mechanical design
The controller consists of 3 parts:
•Plastic housing with digital display accommodating the electronics, operating ele-
ments and built-in room temperature sensor
•Baseplate (mounting base)
•Removable battery compartment
The housing engages in the baseplate and snaps on. The baseplate carries the screw
terminals. There is a reset button on the rear of the unit.
Display
Backup
4/8
Siemens Room temperature controllers CE1N3071en
Building Technologies 19.11.2007
1 Display of the room temperature in °C
2 Indicates a request for heat
3 Indicates low battery power; replace batteries
4 Time of day (00:00…23:59 format)
5 Time setting position
6 First switch ON time
7 First switch OFF time
8 Second switch ON time
9 Second switch OFF time
10 Comfort temperature setting
11 Energy saving temperature setting
12 RUN position
13 Programming slider
14 Advance button (override / presence button)
15 Temperature setting knob
16 Operating mode slider
17 Battery compartment
18 Frost Protection; the RDJ10 controls to the fixed temperature setpoint for frost
protection
19 Energy Saving mode; the RDJ10 controls continuously to the energy saving
temperature setpoint
20 Comfort mode; the RDJ10 controls continuously to the comfort temperature
setpoint
21 Automatic mode; the RDJ10 operates according to the selected time and tem-
perature program
22 Indicates second switch ON / OFF time
23 Indicates first switch ON / OFF time
24 Indicates that programming is taking place
25 Setpoint is overridden temporarily (by advance button) until the next switching
time
26 The RDJ10 controls to the fixed frost protection temperature setpoint
27 The RDJ10 controls to the adjusted energy saving temperature setpoint
28 The RDJ10 controls to the adjusted comfort temperature setpoint
Key
5/8
Siemens Room temperature controllers CE1N3071en
Building Technologies 19.11.2007
Notes
Mount the room temperature controller in a location where the air temperature can be
acquired as accurately as possible without getting adversely affected by direct solar
radiation or other heat or refrigeration sources.
Mounting height is about 1.5 m above the floor.
The unit can be fitted to a recessed conduit box.
When mounting the unit, fix the baseplate first. Then, make the electrical connections
and fit and secure the controller (also refer to separate mounting instructions).
Mount the controller on a flat wall and in compliance with local regulations.
If there are thermostatic radiator valves in the reference room, set them to their fully
open position.
The controller is maintenance-free.
If the battery symbol appears, the batteries are almost exhausted and must be re-
placed.
To reset, press the reset button on the rear of the unit. All individual settings are then
reset to their default values.
Technical data
Operating voltage DC 3 V (2 x 1.5 V AA alkaline batteries)
Battery life >1 year (with AA alkaline batteries)
Internal:
Thermistor 10 kΩ± 1% at 25 °C
Relay contacts
Switching voltage Max. AC 250 V
Min. AC 24 V
Switching current Max. 5 A res., 2 A ind.
At AC 250 V Min. 200 mA
Contact life at AC 250 V Guide value:
At 5 A res. 1 x 105cycles
Insulating strength
Between relay contacts and coil AC 3,750 V
Between relay contacts (same pole) AC 1,000 V
Switching differential SD 1 K
Setpoint setting range 5…30 °C (Comfort mode)
5…30 °C (Energy Saving mode)
5 °C (Frost Protection, fixed value)
Factory setting for Comfort mode 20 °C
Factory setting for Energy Saving 10 °C
mode
Mounting, installation
and commissioning
Maintenance
Change of batteries
Reset
Power supply
Sensor inputs
Outputs
Switching outputs
(LX, L1, L2)
Operational data
6/8
Siemens Room temperature controllers CE1N3071en
Building Technologies 19.11.2007
Resolution of settings and displays
Temperature setpoints 0.5 °C
Display of actual temperature value 0.5 °C
Display of time of day 1 min
Connection terminals Screw terminals
(via mounting plate)
For solid wires 2 x 1.5 mm2
For stranded wires 1 x 2.5 mm2 (min. 0.5 mm2)
Operation To IEC 721-3-3
Climatic conditions Class 3K5
Temperature 0…+40 °C
Humidity <90% r.h.
Transport To IEC 721-3-2
Climatic conditions Class 2K3
Temperature -25…+60 °C
Humidity <95% r.h.
Mechanical conditions Class 2M2
Storage To IEC 721-3-1
Climatic conditions Class 1K3
Temperature -10…+60 °C
Humidity <90% r.h.
conformity to
EMC directive 2004/108/EC
Low-voltage directive 2006/95/EC
N474 C-tick conformity to
Test standards and requirements EN 61000-6-3, AS/NZS 4251.1:1999
Product standards
Automatic electrical controls for EN 60730- 1 and
household and similar use EN 60730- 2-9
Information technology equipment-
Safety-General Requirements EN 60950-1
Generic standards-Compliance to
lower power electronic apparatus EN 50371-1
Safety class II to EN 60730
Pollution degree 2
Degree of protection of housing IP20
Weight (including packaging)
RDJ10 340 g
Color of housing front Signal-white RAL 9003
Housing material ABS (LCD lens: PC)
Electrical connections
Environmental conditions
Standards
General
7/8
Siemens Room temperature controllers CE1N3071en
Building Technologies 19.11.2007
Lx, Nx Live, neutral conductor, AC 24...250 V
Lx, L2 N.C. contact (for N.O. valves)
Lx, L1 N.O. contact (for N.C. valves)
Connection diagram
Lx
Nx
3071A01
RDJ10
L1
Lx
3V
L2
5(2) Amax.
Application examples
T
T
F1
F2
N1
M1
Y2
2222S01
T
T
F1
F2
N1
M1
Y2
2222S02
T T
Room temperature controller with direct
control of a gas-fired wall-hung boiler
Room temperature controller with direct
control of a gas-fired floor-standing boiler
T
N1
Y1
2222S03
M1
Room temperature controller with direct
control of a heating circuit pump (precontrol
by manual mixing valve)
F1 Thermal reset limit thermostat
F2 Safety limit thermostat
M1 Circulating pump
N1 Room temperatures controller RDJ10
Y1 3-port valve with manual adjustment
Y2 Magnetic valve
8/8
Siemens Room temperature controllers CE1N3071en
Building Technologies 19.11.2007
Dimensions
Room temperature
controller
Baseplate
©2007 Siemens Switzerland Ltd Subject to change

Other Siemens Thermostat manuals

Siemens G2255 series User manual

Siemens

Siemens G2255 series User manual

Siemens RDS110.R User manual

Siemens

Siemens RDS110.R User manual

Siemens RDF660MB Series User manual

Siemens

Siemens RDF660MB Series User manual

Siemens REV34 User manual

Siemens

Siemens REV34 User manual

Siemens RDF302 Operator's manual

Siemens

Siemens RDF302 Operator's manual

Siemens RDG100 Series Operator's manual

Siemens

Siemens RDG100 Series Operator's manual

Siemens RDF310.2/MM User manual

Siemens

Siemens RDF310.2/MM User manual

Siemens RDS110.R User manual

Siemens

Siemens RDS110.R User manual

Siemens REV17 Series User manual

Siemens

Siemens REV17 Series User manual

Siemens RDY2000 User manual

Siemens

Siemens RDY2000 User manual

Siemens RAB10.1U User manual

Siemens

Siemens RAB10.1U User manual

Siemens REV17 Series User manual

Siemens

Siemens REV17 Series User manual

Siemens RDH100RF/SET User manual

Siemens

Siemens RDH100RF/SET User manual

Siemens RDE10.1DHW User manual

Siemens

Siemens RDE10.1DHW User manual

Siemens RDG160TU User manual

Siemens

Siemens RDG160TU User manual

Siemens RDG110 User manual

Siemens

Siemens RDG110 User manual

Siemens DF301 Operator's manual

Siemens

Siemens DF301 Operator's manual

Siemens RDS120 User manual

Siemens

Siemens RDS120 User manual

Siemens RDE100 Series User manual

Siemens

Siemens RDE100 Series User manual

Siemens QAW20 User manual

Siemens

Siemens QAW20 User manual

Siemens EcoView User manual

Siemens

Siemens EcoView User manual

Siemens REV200.03RF User manual

Siemens

Siemens REV200.03RF User manual

Siemens RDG100 Series User manual

Siemens

Siemens RDG100 Series User manual

Siemens RDH100RF/SET User manual

Siemens

Siemens RDH100RF/SET User manual

Popular Thermostat manuals by other brands

Robertshaw 9200 user manual

Robertshaw

Robertshaw 9200 user manual

SCI USA FMT-24-SUPER-PROG owner's manual

SCI USA

SCI USA FMT-24-SUPER-PROG owner's manual

PowerStream UtilityPro Quick reference guide

PowerStream

PowerStream UtilityPro Quick reference guide

Braeburn 1005NC user manual

Braeburn

Braeburn 1005NC user manual

Braeburn 6100 Installer's guide

Braeburn

Braeburn 6100 Installer's guide

Peco TA155-046 Quick manual

Peco

Peco TA155-046 Quick manual

Pro 1 IAQ T855i quick start guide

Pro 1 IAQ

Pro 1 IAQ T855i quick start guide

Pro 1 IAQ T801 operating manual

Pro 1 IAQ

Pro 1 IAQ T801 operating manual

Pro 1 IAQ true comfort iii t721 operating manual

Pro 1 IAQ

Pro 1 IAQ true comfort iii t721 operating manual

Contro l4 CCZ-101-W installation guide

Contro l4

Contro l4 CCZ-101-W installation guide

Pro 1 IAQ True Comfort II T605-2 operating manual

Pro 1 IAQ

Pro 1 IAQ True Comfort II T605-2 operating manual

eControls Comfort365 C365T11 user manual

eControls

eControls Comfort365 C365T11 user manual

Seabreeze TSN11X Installation and operation manual

Seabreeze

Seabreeze TSN11X Installation and operation manual

Pro 1 IAQ T755 Installation tips

Pro 1 IAQ

Pro 1 IAQ T755 Installation tips

EasyHeat SL-2G installation instructions

EasyHeat

EasyHeat SL-2G installation instructions

EasyHeat Warm Tiles FGS Operating & installation instructions

EasyHeat

EasyHeat Warm Tiles FGS Operating & installation instructions

Nu-Heat Home operating manual

Nu-Heat

Nu-Heat Home operating manual

BOSSCO BPS242RF Mounting & wiring Instructions

BOSSCO

BOSSCO BPS242RF Mounting & wiring Instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.