manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SightLife
  6. •
  7. Medical Equipment
  8. •
  9. SightLife EndoSerter Instructions for use

SightLife EndoSerter Instructions for use

For more information or to order, please contact us at
336 784 4603 or visit www.sightlife.org/Resources/EndoSerter
Clinical In-Servicing
SightLife®offers the EndoSerter®corneal
endothelial delivery instrument used to implant
donor allograft tissue during Descemet’s Stripping
Endothelial Keratoplasty (DSEK) procedures.
Consistent, Controlled
Placement of Donor Tissue
Integral Irrigation
Single 4mm Incision
CLINICAL IN-SERVICING
•Do NOT remove black locking guard from the EndoSerter®until ready to insert tissue into anterior chamber.
•The EndoSerter®is designed to be used through a tight 4mm incision.
Information is provided as a supplemental guide only and does not replace the Instructions for Use (IFU).
1. CONNECT irrigation to the EndoSerter®FLUSH
EndoSerter®with Balanced Salt Solution (bottle height
40cm) STOP irrigation (DO NOT restart irrigation until
tip of the EndoSerter®is in anterior chamber).
2. LEAVE a small amount of fluid on the carrier. REMOVE
excess fluid from carrier (do not shake the EndoSerter®
to remove fluid).
3. LOAD tissue onto carrier within alignment holes.
4. DRY around edge of graft with sponge tip.
5. APPLY 2-3 drops of cohesive visco-elastic to center
of graft.
6. ROTATE blue thumbscrew to retract tissue. TUCK
tissue edge, as necessary, to retract fully into sheath.
Rotate thumbscrew until you hear a click and thumb-
screw spins freely − you cannot rotate thumbscrew too
many times.
7. ROLL the EndoSerter®180 degrees so that the black
deployment wheels are facing up.
8. HOLD black deployment wheels firmly and REMOVE
black locking guard (continue to hold deployment
wheels through entire insertion process).
9. INSERT the EndoSerter®tip through a tight 4mm
incision (continue to hold deployment wheels).
10. START and CONTINUE irrigation (bottle height 40cm)
(continue to hold deployment wheels). If necessary,
deepen the chamber slowly by raising the bottle height
while irrigation continues to flow
11. MOVE the EndoSerter®tip across the anterior
chamber past the far edge of the stromal bed
(continue to hold deployment wheels)
12. ROLL black deployment wheels forward (towards
patient) and ROTATE the EndoSerter®45 degrees to
the right as the graft is exposed. The graft is uncovered,
not ejected. The EndoSerter®will retract leaving the
graft behind.
• Graft Size: Diameter ≤8.5mm;
Thickness ≤175µm.
• Sterile, single use disposable.
DSEK / DSAEK
E S -15 3 - J U L16
CLINICAL IN-SERVICING
336 784 4603
www.sightlife.org/Resources/EndoSerter
101 N. Chestnut Street, Ste 303
Winston-Salem, NC 27101

Popular Medical Equipment manuals by other brands

Biowave BioWaveGO Quick reference guide

Biowave

Biowave BioWaveGO Quick reference guide

Kartsana Fuego TGR-244 instruction manual

Kartsana

Kartsana Fuego TGR-244 instruction manual

ECOPOSTURAL C3565 instructions

ECOPOSTURAL

ECOPOSTURAL C3565 instructions

Gima OXY-3 user manual

Gima

Gima OXY-3 user manual

EKO Device CORE user guide

EKO Device

EKO Device CORE user guide

GE b30 User's reference manual

GE

GE b30 User's reference manual

DeguDent SOLARIS Service manual

DeguDent

DeguDent SOLARIS Service manual

SOMNOmedics SOMNO HD Eco instruction manual

SOMNOmedics

SOMNOmedics SOMNO HD Eco instruction manual

Proactive alevia instructions

Proactive

Proactive alevia instructions

Gima MT BASE PLUS instruction manual

Gima

Gima MT BASE PLUS instruction manual

Novametrix Medical Systems OXYPLETH 520A Service manual

Novametrix Medical Systems

Novametrix Medical Systems OXYPLETH 520A Service manual

Ergotron StyleView SV40 manual

Ergotron

Ergotron StyleView SV40 manual

Dewert 2000XL Series user manual

Dewert

Dewert 2000XL Series user manual

Ossur ICEROSS SEAL-IN V Instructions for use

Ossur

Ossur ICEROSS SEAL-IN V Instructions for use

Siemens AXIOM Iconos R200 Operator's manual

Siemens

Siemens AXIOM Iconos R200 Operator's manual

Ergotron StyleView LiFe Power Upgrade System installation manual

Ergotron

Ergotron StyleView LiFe Power Upgrade System installation manual

Medit i700 user manual

Medit

Medit i700 user manual

Ethicon Endo-Surgery ECHELON FLEX 45 instructions

Ethicon Endo-Surgery

Ethicon Endo-Surgery ECHELON FLEX 45 instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.