SIGMA TEK ETT 1264 User manual

Date of creation: 16.12.2021 Version date: 28.03.2022 Article number: 01-230-1264-E
ETT 1264
Multi-touch Operating Panel
Operating Manual

Publisher: SIGMATEK GmbH & Co KG
A-5112 Lamprechtshausen
Tel.: +43/6274/4321
Fax: +43/6274/4321-18
Email: [email protected]
WWW.SIGMATEK-AUTOMATION.COM
Copyright © 2021
SIGMATEK GmbH & Co KG
Translation from German
All rights reserved. No part of this work may be reproduced, edited using an electronic system, duplicated or
distributed in any form (print, photocopy, microfilm or in any other process) without express permission.
We reserve the right to make changes in the content without notice. SIGMATEK GmbH & Co KG is not responsible
for technical or printing errors in this handbook and assumes no responsibility for damages that occur through
its use.

MULTI-TOUCH OPERATING PANEL ETT 1264
Multi-touch Operating Panel ETT 1264
The ETT 1264 is an intelligent panel for visualizing, operating and monitoring automated
processes. Process diagnostics is therewith simplified.
A projective capacitive touch screen serves as the input medium for process data and
parameters. The output is shown on a 12.1“ TFT color display.
The available interfaces can be used to exchange process data or configure the multi-touch
terminal.
28.03.2022 Page 1

ETT 1264 MULTI-TOUCH OPERATING PANEL
Table of Contents
1 Introduction 5
1.1 Target Group/Purpose of this Operating Manual 5
1.2 Important Reference Documentation 5
1.3 Contents of Delivery 5
2 Basic Safety Guidelines 6
2.1 Symbols Used 6
2.2 Disclaimer 8
2.3 General Safety Guidelines 9
2.4 Software/Training 10
3 Standards and Guidelines 11
3.1 Guidelines 11
3.1.1 EU Conformity Declaration 11
4 Technical Data 12
4.1 Performance Data 12
4.2 Electrical Requirements 13
4.3 Display 14
4.4 Control Unit 15
4.5 Minimum Distance between Operating Elements for Multi-touch Applications 16
4.6 Input 17
4.7 Environmental Conditions 17
4.8 Miscellaneous 17
5 Interfaces 18
5.1 Rear Connectors 18
5.1.1 X1: Supply (4-pin Phoenix RM 3.5) 18
5.1.2 X2, X3: Ethernet 1, 2 (10/100/1000 Mbit/s) (RJ45) 18
5.1.3 X4, X5: USB 2.0 (Type A) 19
Page 2 28.03.2022

MULTI-TOUCH OPERATING PANEL ETT 1264
5.1.4 X6: microSD 19
5.1.5 X7: USB Online OTG 2.0 (Type Mini-B) 20
5.2 Applicable Connectors 20
5.3 Status Display LEDs 21
6 Mechanical Dimensions 22
7 Assembly/Installation 23
7.1 Check Contents of Delivery 23
7.2 Installation 23
7.3 Mounting Instructions 23
7.3.1 Required Cutout for Mounting the Terminal 24
7.3.2 Mounting Position 25
7.3.3 Minimum Distance Installation 26
8 Wiring 27
8.1 Grounding 27
8.2 Shielding 27
8.3 ESD Protection 28
8.4 USB Interface 28
9 Process Diagram 29
10 Status and Error Messages 30
11 Transport/Storage 40
12 Storage 41
13 Maintenance 42
13.1 Cleaning and Disinfecting the Touch Screen 42
13.2 Service 43
13.2.1 Calibrating the Touch Screen 43
13.3 Repair 44
14 Buffer Battery 45
28.03.2022 Page 3

ETT 1264 MULTI-TOUCH OPERATING PANEL
14.1 Data Retention Battery Change 46
14.2 Exchanging the Battery 46
15 Display „Burn-In“ Effect 47
15.1 Screen Saver 47
16 Disposal 49
17 Accessories 50
17.1 Touch Pen 50
17.2 Battery 50
17.3 microSD Card 50
18 Application Information 51
18.1 Storage Media 51
Page 4 28.03.2022

MULTI-TOUCH OPERATING PANEL ETT 1264
1 Introduction
1.1 Target Group/Purpose of this Operating Manual
This operating manual contains all information required for the operation of the product.
This operating manual is intended for:
lProject planners
lTechnicians
lCommissioning engineers
lMachine operators
lMaintenance/test technicians
General knowledge of automation technology is required.
Further help and training information, as well as the appropriate accessories can be found on
our website www.sigmatek-automation.com.
Our support team is happily available to answer your questions.
Please see our website for our hotline number and business hours.
1.2 Important Reference Documentation
lHW IP Address Settings
This and additional documents can be downloaded from our website or obtained through
support.
1.3 Contents of Delivery
1x ETT 1264
8x angle bracket
1x 4-pin Phoenix connector plug
28.03.2022 Page 5

ETT 1264 MULTI-TOUCH OPERATING PANEL
2 Basic Safety Guidelines
2.1 Symbols Used
The following symbols are used in the operator documentation for warning and danger
messages, as well as informational notes.
DANGER
Danger indicates that death or serious injury will occur, if the specified
measures are not taken.
To avoid death or serious injuries, observe the all guidelines.
Danger indique une situation dangereuse qui, faute de prendre les
mesures adéquates, entraînera des blessures graves, voire mortelles.
Respectez toutes les consignes pour éviter des blessures
graves, voire mortelles.
WARNING
Warning indicates that death or serious injury can occur, if the specified
measures are not taken.
To avoid death or serious injuries, observe the all guidelines.
Avertissement d’une situation dangereuse qui, faute de prendre les
mesures adéquates, entraînera des blessures graves, voire mortelles.
Respectez toutes les consignes pour éviter des blessures
graves, voire mortelles.
Page 6 28.03.2022

MULTI-TOUCH OPERATING PANEL ETT 1264
CAUTION
Caution indicates that moderate to slight injury can occur, if the
specified measures are not taken.
To avoid moderate to slight injuries, observe the all guidelines.
Attention indique une situation dangereuse qui, faute de prendre les
mesures adéquates, peut entraîner des blessures assez graves ou
légères.
Respectez toutes les consignes pour éviter des blessures
graves, voire mortelles.
CAUTION
Danger for ESD-sensitive components.
Les signes de danger pour les composants sensibles aux décharges
électrostatiques.
INFORMATION
INFORMATION
Provides important information on the product, handling or
relevant sections of the documentation, which require particular
attention.
28.03.2022 Page 7

ETT 1264 MULTI-TOUCH OPERATING PANEL
2.2 Disclaimer
INFORMATION
The contents of this operating manual were prepared with the greatest
care. However, deviations cannot be ruled out. This operating manual is
regularly checked and required corrections are included in the subsequent
versions. The machine manufacturer is responsible for the proper
assembly, as well as device configuration. The machine operator is
responsible for safe handling, as well as proper operation.
The current operating manual can be found on our website. If necessary,
contact our support.
Subject to technical changes, which improve the performance of the
devices. The following operating manual is purely a product description. It
does not guarantee properties under the warranty.
Please thoroughly read the corresponding documents and this operating
manual before handling a product.
SIGMATEK GmbH & Co KG is not liable for damages caused
through, non-compliance with these instructions or applicable
regulations.
Page 8 28.03.2022

MULTI-TOUCH OPERATING PANEL ETT 1264
2.3 General Safety Guidelines
The Safety Guidelines in the other sections of this operating manual must be observed. These
instructions are visually emphasized by symbols.
INFORMATION
According to EU Guidelines, the operating manual is a component of a
product.
This operating manual must therefore be accessible in the vicinity of the
machine since it contains important instructions.
This operating manual should be included in the sale, rental or transfer of
the product, or its online availability indicated.
Maintain this operating manual in readable condition and keep it
accessible for reference.
Regarding the requirements for Safety and health connected to the use of
machines, the manufacturer must perform a risk assessment in
accordance with machine guidelines 2006/42/EG before introducing a
machine to the market. Before commissioning this product, check that
conformance with the provisions of the 2006/42/EG guidelines is correct.
As long as the machine with which the product should be used does not
comply with the guideline, operating this product is prohibited.
Operate the unit with devices and accessories approved by SIGMATEK
only.
28.03.2022 Page 9

ETT 1264 MULTI-TOUCH OPERATING PANEL
CAUTION
Handle the device with care and do not drop or let fall.
Prevent foreign bodies and fluids from entering the device.
The device must not be opened, otherwise it could be damaged!
Manipulez l’appareil avec précaution et ne le laissez pas tomber.
Empêchez les corps étrangers et les liquides de pénétrer dans l’appareil.
L’appareil ne doit pas être ouvert, sinon il risque d’être endommagé!
The module complies with EN 61131-2.
In combination with a machine, the machine builder must comply with EN
60204-1 standards.
For your own safety and that of others, compliance with the environmental
conditions is essential.
The control cabinet must be connected to ground correctly.
To perform maintenance or repairs, disconnect the system from the power
supply.
Le module est conforme à la norme EN 61131-2.
En combinaison avec une machine, le constructeur de la machine doit
respecter la norme EN 60204-1.
Pour votre propre sécurité et celle des autres, le respect des conditions
environnementales est essentiel.
L’armoire de commande doit être raccordée correctement à la terre.
Pour l'entretien et les réparations, débranchez le système de
l'alimentation.
INFORMATION
Hardware and software features (application-specific data) can be found
in chapter 18 Application Information.
2.4 Software/Training
The application is created with the software LASAL CLASS 2 and LASAL SCREEN Editor /
VISUDesigner (HTML5).
Training for the LASAL development environment, with which the product can be configured,
is provided. Information on our training schedule can be found on our website.
Page 10 28.03.2022

MULTI-TOUCH OPERATING PANEL ETT 1264
3 Standards and Guidelines
3.1 Guidelines
The product was constructed in compliance with the following European Union guidelines and
tested for conformity.
3.1.1 EU Conformity Declaration
EU Declaration of Conformity
The product ETT 1264 conforms to the following European guidelines:
2014/35/EU Low-voltage Guideline
2014/30/EU Electromagnetic Compatibility (EMC Guideline)
2011/65/EU “Restricted use of certain hazardous substances in
electrical and electronic equipment” (RoHS Guideline)
The EU Conformity Declarations are provided on the SIGMATEK website.
See Products/Downloads or use the search function and the keyword “EU
Declaration of Conformity”.
28.03.2022 Page 11

ETT 1264 MULTI-TOUCH OPERATING PANEL
4 Technical Data
4.1 Performance Data
Processor EDGE3-Technology
Processor cores 41)
Internal program and
data memory (RAM)
2-GByte (DDR4)
Internal remnant data memory 128-kByte FRAM
Internal storage device 8-GByte eMMC2)
Optional memory expansion microSD2)
Graphic integrated in EDGE processor
Interfaces 2x Ethernet (10/100/1000)
2x USB 2.0 Type A
1x USB 2.0 Type Mini-B OTG
1x microSD card holder (SD 3.0)
Internal interface connections
and devices
no
Operating components no
Signal generator no
Display
Resolution
12.1“ TFT color display
WXGA 1280 x 800 pixels
Operating field Touch screen (multi-touch, projective capacitive)
Status LEDs yes (1x red/1x green)
Real-time clock yes (battery buffered)
Cooling passive
1) Attention: When programming on multi-core CPUs (with LASAL), particular focus must be placed on thread security!
2) The internal storage device (eMMC) is only available from later operating system versions and is currently mapped via
an 8 GByte microSD card. The microSD card is no longer part of the scope of delivery once this functionality is
implemented in the operating system.
Page 12 28.03.2022

MULTI-TOUCH OPERATING PANEL ETT 1264
4.2 Electrical Requirements
Supply voltage +24 V DC ±20 % (SELV/PELV)
UL: Class 2 of LVLC
Protection class III
Current consumption of (+24 V)
power supply
typically 500 mA
(with no external devices
connected)
maximum 760 mA
(with external devices connected)
Inrush current without current-
limiting supply
30 A for max. 20 µs
Inrush current with 24 V/10 A
fixed voltage supply
1 A for max. 30 ms
INFORMATION
For USA and Canada:
The supply must be limited to:
a) max. 5 A at voltages from 0-20 V DC, or
b) 100 W at voltages from 20-60 V DC
The limiting component (e.g. transformer, power supply or fuse) must be
certified by an NRTL (Nationally Recognized Testing Laboratory).
28.03.2022 Page 13

ETT 1264 MULTI-TOUCH OPERATING PANEL
4.3 Display
Type 12.1” TFT color display
Resolution WXGA 1280 x 800 pixels
Color depth 18-Bit RGB
LCD mode normally black1)
LCD Polarizer transmissive2)
Pixel size 0.2040 x 0.2040 mm
Active range 261.12 x 163.20 mm
Backlighting LED
Contrast ratio typically 1000:1
Brightness typically 400 cd/m²
Angle CR ≥ 10 left, right, top, bottom typically 89°3)
Life span By compliance with the ambient conditions, the brightness of the display
sinks after 50,000 operating hours to 50 % of the original brightness.
Due to the manufacturing process, individual pixel errors cannot be excluded to 100 % and therefore do not constitute a
reduction in quality.
1) If there is no display data, the display remains black when the backlighting is on.
2) Display technology, with which display backlighting is used.
3) The viewing angle is measured from the normal to the display surface.
Page 14 28.03.2022

MULTI-TOUCH OPERATING PANEL ETT 1264
4.4 Control Unit
Operating field Touch screen (multi-touch, projective capacitive)
Maximum number of fingers 5
The operation with thin gloves yes
SIGMATEK Touch pen (passive) yes
Handwriting recognition no
Ball of the thumb recognition no
Water spray recognition1) no
Water detection2) no
Cleaning see chapter 13.1 Cleaning and Disinfecting the Touch Screen
INFORMATION
The device must always be grounded or with cable-connected devices,
the mass must be connected correctly to ensure stable function of the
touch screen. The touch function may still have to be individually adapted
to the respective environmental conditions.
1) Detects individual water droplets on the touch screen and remains operable.
2) Detects a large amount of water on the touch screen and deactivates it.
28.03.2022 Page 15

ETT 1264 MULTI-TOUCH OPERATING PANEL
4.5 Minimum Distance between Operating Elements for Multi-touch
Applications
To guarantee smooth operation with multi-touch applications, buttons and control elements
that should be operated at the same time must have a realistic minimum clearance.
INFORMATION
The size of the buttons and operating elements directly affect the
operability of the application. Small operating elements should therefore
be avoided.
Page 16 28.03.2022

MULTI-TOUCH OPERATING PANEL ETT 1264
4.6 Input
Input Multi-touch screen (PCAP)
4.7 Environmental Conditions
Storage temperature -10 … +70 °C
Environmental temperature 0 … +55 °C
Humidity 10-95 %, non-condensing
Installation altitude above sea
level
0-2000 m without derating
> 2000 m up to a maximum of 5000 m with derating of the maximum
environmental temperature by 0.5 °C per 100 m
Operating conditions pollution degree 2
EMC resistance according to EN 61000-6-2 (industrial area)
EMC noise generation according to EN 61000-6-3 (residential area)
according to EN 61000-6-4 (industrial area)
Vibration resistance EN 60068-2-6 3.5 mm from 5-8,4 Hz
1 g from 8.4-150 Hz
Shock resistance EN 60068-2-27 15 g (147.15 m/s2)
Protection type EN 60529
protection through housing
front: IP65
cover: IP20
4.8 Miscellaneous
Article number 01-230-1264
Hardware version 1.x
Operating system Gecko
Default IP address 10.10.150.1
Standard UL in preparation
Approvals CE
28.03.2022 Page 17

ETT 1264 MULTI-TOUCH OPERATING PANEL
5 Interfaces
5.1 Rear Connectors
5.1.1 X1: Supply (4-pin Phoenix RM 3.5)
Pin Function
1 +24 V DC
2 +24 V DC
3 GND
4 GND
5.1.2 X2, X3: Ethernet 1, 2 (10/100/1000 Mbit/s) (RJ45)
Pin Function
1 DA+
2 DA-
3 DB+
4 DC+
5 DC-
6 DB-
7 DD+
8 DD-
INFORMATION
Problems can arise if a control is connected to an IP network, which
contains modules that are not running with a SIGMATEK operating
system. With such devices, Ethernet packets could be sent to the control
with such a high frequency (i.e. broadcasts), that the high interrupt load
could cause a real-time runtime error or runtime error. By configuring the
packet filter (Firewall or Router) accordingly however, it is possible to
connect a network with SIGMATEK hardware to a third party network
without triggering the error mentioned above.
Page 18 28.03.2022