SIMARINE SC302T User manual

EN
DE
SIMARINE SC302T
SIMARINE SC502T
Active digital shunt
USER MANUAL
Revision 1.0
www.simarine.net

SC302T / SC502T
2
EN
Table of Contents
Introduction .....................................................................................................3
Safety ...............................................................................................................3
Declaration of conformity................................................................................4
Overview..........................................................................................................4
Installation .......................................................................................................5
Mounting.................................................................................................5
Cables......................................................................................................5
Power cable ........................................................................................5
SiCOM data cable................................................................................5
Connecting ..............................................................................................6
SC302T / SC502T installed on the minus terminal of the battery
/ battery bank ..................................................................................................7
Technical Specifications ...................................................................................8
SC302T.....................................................................................................8
SC502T.....................................................................................................9
Troubleshooting.............................................................................................10
Negative current values ........................................................................10
Shunt is not visible on PICO ..................................................................10
APPENDIX.......................................................................................................11

SC302T / SC502T
3
EN
Introduction
Simarine high precision SC302T / SC502T digital shunt is an innovative combination
of a shunt and a tank level module.
SC302T / SC502T active combo shunt precisely monitors battery voltage on 12V,
24V, 48V, 60V and 72V systems, battery temperature and continuous currents up
to 300A (400A peak). It’s suitable for a maximal power of 3600W at 12V or 7200W
at 24V. It is equipped with one additional battery voltage input (2 in total).
The integrated tank level module has 2 resistance-type inputs for tank level
monitoring and temperature sensors.
Additionally, the SC302T / SC502T module can also be used for monitoring current
draw of heavy consumers like inverters, bow and stern thrusters, anchor winches
and current generated on generators like shore power chargers, solar panels,
hydro- and wind generators.
SC302T / SC502T innovative protected architecture allows wiring in either negative
(up to 72V) or positive (up to 24V) side.
Safety
Installation of Simarine electronics should be made by electrical specialists with
proper safety equipment. When working with batteries you should wear protective
clothing and eye protection.
CAUTION: Batteries contain acid, a corrosive, colorless liquid that will burn your
eyes, skin and clothing. Should the acid come in contact with eyes, skin or clothing,
wash it immediately with soap under fresh water for at least 15 minutes, and seek
medical support immediately.
CAUTION: Do NOT connect anything to a damaged battery. It could heat up, catch
fire or explode.
CAUTION: Lead-acid batteries can generate explosive gases during operation.
Never smoke, allow flames or sparks near the battery. Make sure to keep sufficient
ventilation around the battery.
CAUTION: When working with a battery, remove all personal metal items like
watches, rings, necklaces and bracelets. Metal items in contact with the battery
terminals might cause a short circuit with a very high electric current, which may
heat up and melt nearby objects and cause severe burns.

SC302T / SC502T
4
EN
Declaration of conformity
Conforms to the requirements of the following Directives of the European Union:
EMC Directive 2014/30EU, RoHS Directive 2002/95/EC
The above product is in conformity with the following harmonized standards:
EN61000-6-3: 2001 EMC - Generic Emissions Standard, EN61000-6-2: 2005 EMC -
Generic Immunity Standard
Overview
A –1x battery input
D –2x resistance sensing input
B –1x battery output
E –2x SiCOM port
C –2x voltage sensing input
MANUFACTURER:
SIMARINE d.o.o.
ADDRESS:
Ulica skofa Maksimilijana Drzecnika 6,
SI-2000 Maribor, Slovenia, EU
Declares that the following products:
PRODUCT TYPE:
SC302T, SC502T

SC302T / SC502T
5
EN
Installation
Mounting
1. Remove the shunt cover by unscrewing four screws on top of the shunt
cover.
2. To install the shunt using supplied voltage cables find a place no further
than 3 m away from the battery / battery bank. You can fix the shunt with
the supplied screws using four holes on bottom of the casing.
3. Connect all cables (see section 5.3 Connecting).
4. Place back the shunt cover and screw the four screws on the cover of the
shunt unit.
Cables
Power cable
Minimum power cable cross-section requirement at maximal temperature of
insulation: 70 °C (160 °F).
SiCOM data cable
For the SiCOM connection use the supplied cable. If not possible, use the following
table to determinate the right cable type.
!
Install the shunt unit in a clean dry place, protected from accidental spilling
of liquids.
Continuous current
Cable cross-sectional
area
500 A
220 mm2
400 A
150 mm2
300 A
95 mm2
200 A
50 mm2
100 A
25 mm2
!
Failure to observe the required cable cross-sections can damage the shunt,
wiring, or cause fire.

SC302T / SC502T
6
EN
Cable length
Cable type
< 5m
No limitations
>= 5m
2 x 2 x 0.25 mm2Twisted pair (recommended)
Connecting
For proper function of Simarine SC302T / SC502T digital shunt it is necessary to take
the following steps:
1. Disconnect the battery / battery bank plus and minus terminal, for safety
reasons.
2. Connect the shunt to Simarine PICO via one of the SiCOM ports to a
Splitter or any other Simarine product in the network.
3. Connect the shunt voltage sensing input to a battery terminal.
4. Connect a temperature sensor to the resistance input on the shunt and
place it near the battery / battery bank (optional)
5. Connect a tank sensor to the resistance or voltage input, depending on the
sensor type (optional)
6. Connect battery / battery bank minus or plus terminal through the shunt’s
IN terminal.
7. Connect all consumers and charging sources to the OUT terminal on the
shunt.
Each correctly connected shunt needs to be configured. This is done via PICO in an
easy way. The configuration process is described in PICO’s manual.
!
Although the shunt can be connected in the positive or the negative line, it
is recommended that the shunt is installed in the negative line if possible.
!
After connecting the shunt, make sure that all the connections between
cables and shunt are tight. Loose connections may cause sparks, heating and
even a fire. It may also damage the shunt.

SC302T / SC502T
7
EN
SC302T / SC502T installed on the minus terminal of the battery /
battery bank

SC302T / SC502T
8
EN
Technical Specifications
SC302T
Operating
Voltage range
6 –35 V
Temperature range
-20 –+70 °C (0 –+160 °F)
Power consumption at 12V
Operating
1.2 mA
Current Measuring
Range
0.01 –400 A
Accuracy
± 0.6 %
Resolution
0.01 A
Sampling rate
100 ms
Maximal current
Continuous
300 A
Peak current ( <1min )
400 A
Voltage measuring
Range
0 –70 V
Accuracy
± 0.2 %
Resolution
1 mV
Temperature sensor –NTC 5K
Range
-15 –+80 °C (0 –+180 °F)
Accuracy
3 % (-10 –+60 °C)(10 –+140 °F)
Installation and Dimensions
Dimensions
120 x 120 x 60 mm
4.73 x 4.73 x 2.37 in
Connection
M 10 bolts
Connectivity
Up to
Batteries
1
Temperature sensors
2 –resistance, 1 –voltage
Tank level sensors
2 –resistance, 1 –voltage

SC302T / SC502T
9
EN
SC502T
Operating
Voltage range
6 –35 V
Temperature range
-20 –+70 °C (0 – +160 °F)
Power consumption at 12V
Operating
1.2 mA
Current Measuring
Range
0.01 –700 A
Accuracy
± 0.6 %
Resolution
0.01 A
Sampling rate
100 ms
Maximal current
Continuous
500 A
Peak current ( <1min )
600 A
Voltage measuring
Range
0 –70 V
Accuracy
± 0.2 %
Resolution
1 mV
Temperature sensor –NTC 5K
Range
-15 –+80 °C (0 –+180 °F)
Accuracy
3 % (-10 –+60 °C)(10 –+140 °F)
Installation and Dimensions
Dimensions
120 x 120 x 60 mm
4.73 x 4.73 x 2.37 in
Connection
M 10 bolts
Connectivity
Up to
Batteries
1
Temperature sensors
2 –resistance, 1 –voltage
Tank level sensors
2 –resistance, 1 –voltage

SC302T / SC502T
10
EN
Troubleshooting
Negative current values
On PICO screen, consumers are represented with a yellow/red horizontal bar
(meaning that the energy is flowing out of the battery), and generators are
represented with a blue horizontal bar (meaning that the energy is flowing into the
battery). If PICO is showing wrong color for a certain shunt, please check if the shunt
is correctly installed. This means the battery/battery bank minus (optionally plus)
terminal is connected to the IN terminal on the shunt. If this is not the case, you
have two options:
You can reinstall the shunt (reverse the cables connected to IN and OUT
terminals), or
enable the “Reverse”setting for the shunt in PICO settings.
Shunt is not visible on PICO
If the shunt is not visible in PICO’s menu, check the following:
Is the shunt properly connected via the SiCOM port to the PICO?
If you are using your own SiCOM cable, make sure it has the right cross-
section and is twisted.

SC302T / SC502T
11
EN
APPENDIX
Please visit
www.simarine.net/manuals
for most recent User Manuals.
© 2018 Simarine d.o.o. All rights reserved.
No part of this manual may be copied or reproduced without Simarine’s written
permission. Information in this manual is subject to change without notice.

SC302T / SC502T
12
DE
Tabelleninhalt
Einleitung .......................................................................................................13
Sicherheit .......................................................................................................13
Konformitätserklärung...................................................................................14
Überblick........................................................................................................15
Einrichtung.....................................................................................................15
Befestigung ...........................................................................................15
Kabel .....................................................................................................16
Hochleistungskabel...........................................................................16
SiCOM Daten Kabel...........................................................................16
Verdrahtung ..........................................................................................16
SC302T / SC502T auf dem Minus-Terminal der Batterie /
Batterie-Bank installiert.................................................................................18
Technische Einzelheiten.................................................................................19
SC302T...................................................................................................19
SC502T...................................................................................................20
Fehler Beseitigung .........................................................................................21
Negative Stromwerte............................................................................21
Shunt ist nicht sichtbar auf dem PICO...................................................21
ANHANG ........................................................................................................22

SC302T / SC502T
13
DE
Einleitung
Simarine hoch präziser SC302T / SC502T digital Shunt ist eine innovative
Kombination von Shunt und Tankfüllstands-Modul.
Der SC302T / SC502T Active Combo Shunt überwacht präzise die Batteriespannung
an 12V, 24V, 48V, 60V und 72V Systemen, Batterietemperatur und Dauerströme
bis zu 300A / 500A (400A / 600A Spitze). Es ist für eine maximale Leistung von
3600W bei 12V oder 7200W bei 24V geeignet. Er ist mit einem zusätzlichen
Batteriespannungseingang (insgesamt 2) ausgestattet.
Das integrierte Tankfüllstandsmodul verfügt über 2 Widerstandseingänge zur
Überwachung von Tankfüllstand und Temperatur.
Darüber hinaus kann das SC302T / SC502T Modul auch zur Überwachung der
Stromaufnahme größerer Verbraucher wie Wechselrichter, Bug und
Heckstrahlruder sowie Ankerwinden und der Generatoren wie
Landstromverbraucher, Solarmodule, Wasser und Windgeneratoren verwendet
werden.
Die innovative geschützte Architektur des SC302T / SC502T ermöglicht die
Verdrahtung auf einer negativen (bis zu 72 V) oder positiven (bis zu 24 V) Seite.
Sicherheit
Installation der Simarine Elektronik sollte von Elektrofachkräften durchgeführt
werden. Wenn Sie mit Batterien arbeiten, sollten Sie Schutzkleidung und
Augenschutz tragen.
VORSICHT: Die Batterien enthalten Säure, eine korrosive, farblose Flüssigkeit, die
Augen, Haut und Kleidung verbrennen wird. Falls Säure in Kontakt mit Augen, Haut
oder Kleidung kommt, waschen Sie sie sofort mit Seife unter Süßwasser für
mindestens 15 Minuten und sofort medizinische Unterstützung suchen.
VORSICHT: Schließen Sie NICHTS an eine beschädigte Batterie an. Sie könnte
aufheizen, Feuer fangen oder explodieren.
VORSICHT: Blei-Säure-Batterien können während des Betriebs explosive Gase
erzeugen. Rauchen Sie niemals in der Nähe der Batterie. Achten Sie darauf, dass
eine ausreichende Belüftung um die Batterie gegeben ist.
VORSICHT: Beim Arbeiten mit einer Batterie alle persönlichen Metallgegenstände
wie Uhren, Ringe, Halsketten und Armbänder entfernen. Wenn Metallgegenstände

SC302T / SC502T
14
DE
die Batterieklemmen berühren, kann der daraus resultierende Kurzschluss
Gegenstände schmelzen und schwere Verbrennungen verursachen.
Konformitätserklärung
Entspricht den Anforderungen der folgenden Richtlinien der Europäischen Union:
EMC Directive 2014/30EU, RoHS Directive 2002/95/EC
Das oben genannte Produkt entspricht den folgenden harmonisierten Normen:
EN61000-6-3: 2001 EMC - Generic Emissions Standard, EN61000-6-2: 2005 EMC -
Generic Immunity Standard
HERSTELLER:
SIMARINE d.o.o.
ADRESSE:
Ulica skofa Maksimilijana Drzecnika 6,
SI-2000 Maribor, Slovenia, EU
Declares that the following product:
PRODUKTTYP:
SC302T, SC502T

SC302T / SC502T
15
DE
Überblick
A –1x Batterie
D –2x Widerstand Erfassungseingang
B –1x hub - GND
E –2x SiCOM Schnittstelle
C –2x Spannung Erfassungseingang
Einrichtung
Befestigung
1. Entfernen Sie den Shunt-Deckel, indem Sie vier Schrauben auf dem Shunt-
Deckel herausdrehen.
2. Zur Installation des Shunts mit den mitgelieferten Spannungsleitungen
finden Sie einen Platz, der nicht mehr als 3 m von der
Batterie/Batteriebank entfernt ist. Sie können den Shunt mit den
mitgelieferten Schrauben mit vier Löchern auf der Unterseite des
Gehäuses befestigen.
3. Schließen Sie alle Kabel an (siehe Abschnitt 5.3 Verdrahtung).
!
Installieren Sie den Shunt an einem sauberen, trockenen Ort, geschützt vor
versehentlichem Verschütten von Flüssigkeiten.

SC302T / SC502T
16
DE
4. Legen Sie den Shunt-Deckel zurück auf dem Shunt und schrauben Sie die
vier Schrauben fest.
Kabel
Hochleistungskabel
Mindestquerschnitt Anforderung des Kabels bei einer Maximalen Temperatur der
Isolierung: 70 °C (160 °F).
SiCOM Daten Kabel
Für die SiCOM Verbindung benutzen sie die mitgelieferten Kabel. Wen das nicht
möglich ist bestimmen sie den Kabel typ, über die Folgende Tabelle.
Kabel Lenge
Kabel typ
< 5m
Keine Beschränkungen
>= 5m
2 x 2 x 0.25 mm2Twisted pair (empfohlen)
Verdrahtung
Für die ordnungsgemäße Funktion des Simarine SC302T / SC502T Digital-Shunts
sind Folgende Schritte notwendig:
1. Trennen Sie die Batterie/Batteriebank plus und minus Klemme, aus
Sicherheitsgründen
2. Verbinden Sie den Shunt mit Simarine PICO, über den SiCOM Anschluss an
den Splitter oder beliebigen Simarine Produkt im Netz.
3. Schlissen Sie den Spannungserfassungseingang des Shunts an eine
Batterieklemme an
Dauerstrom
Querschnitt
500 A
220 mm2
400 A
150 mm2
300 A
95 mm2
200 A
50 mm2
100 A
25 mm2
!
Die Nichtbeachtung der erforderlichen Kabelquerschnitte kann den Shunt
oder die Verdrahtung beschädigen, wie auch einen Brand verursachen.

SC302T / SC502T
17
DE
4. Schlissen Sie den Temperatursensor am Shunt an und legen Sie ihn in die
Nähe der Batterie / Batteriebank (wahlweise).
5. Schlissen Sie den Tanksensor am Shunt an. Wählen Sie den Spannungs
oder Wiederstands Eingang, abhängig von dem Sensor typ (wahlweise).
6. Schlissen Sie die Minus oder Plus Klemme der Batterie / Batterie Bank über
den Shunt IN terminal.
7. Schlissen Sie alle Verbraucher und Generatoren an den Shunt OUT
terminal.
Jeder korrekt angeschlossene Shunt muss konfiguriert werden. Dies geschieht über
den PICO auf eine einfache Weise. Die Konfiguration ist im PICO Handbuch
beschrieben.
!
Obwohl der Shunt in der positiven oder negativen Linie angeschlossen
werden kann, wird empfohlen, den Shunt in der negativen Linie zu
installieren wenn möglich.
!
Nach dem Anschließen des Shunts ist darauf zu achten, dass alle
Verbindungen zwischen den Kabeln und dem Shunt fest sind. Lose
Verbindungen können Funken, Heizung und sogar Feuer verursachen. Es
kann auch den Shunt beschädigen.

SC302T / SC502T
18
DE
SC302T / SC502T auf dem Minus-Terminal der Batterie / Batterie-
Bank installiert

SC302T / SC502T
19
DE
Technische Einzelheiten
SC302T
In Betrieb
Spannungsbereich
6 –35 V
Temperaturbereich
-20 –+70 °C (0 – +160 °F)
Stromverbrauch bei 12V
Operating
1.2 mA
Strom Messung
Bereich
0.01 –400 A
Genauigkeit
± 0.6 %
Auflösung
0.01 A
Abtastgeschwindigkeit
100 ms
Maximal Strom
Durchgehend
300 A
Stromspitze ( <1min )
400 A
Spannung Messung
Bereich
0 –70 V
Genauigkeit
± 0.2 %
Auflösung
1 mV
Temperatur Sensor –NTC 5K
Bereich
-15 –+80 °C (0 – +180 °F)
Genauigkeit
3 % (-10 –+60 °C)(10 – +140 °F)
Installation und Dimensionen
Dimensionen
120 x 120 x 60 mm
4.73 x 4.73 x 2.37 in
Batterie Anschluss
M 10 Schrauben
Anschlussmöglichkeiten
Bis zu
Batterie / Batteriebank
1
Temperatur Sensor
2 –wiederstand, 1 –Spannung
Tank Sensor
2 –wiederstand, 1 –Spannung

SC302T / SC502T
20
DE
SC502T
In Betrieb
Spannungsbereich
6 –35 V
Temperaturbereich
-20 –+70 °C (0 – +160 °F)
Stromverbrauch bei 12V
Operating
1.2 mA
Strom Messung
Bereich
0.01 –700 A
Genauigkeit
± 0.6 %
Auflösung
0.01 A
Abtastgeschwindigkeit
100 ms
Maximal Strom
Durchgehend
500 A
Stromspitze ( <1min )
600 A
Spannung Messung
Bereich
0 –70 V
Genauigkeit
± 0.2 %
Auflösung
1 mV
Temperatur Sensor –NTC 5K
Bereich
-15 –+80 °C (0 – +180 °F)
Genauigkeit
3 % (-10 –+60 °C)(10 – +140 °F)
Installation und Dimensionen
Dimensionen
120 x 120 x 60 mm
4.73 x 4.73 x 2.37 in
Batterie Anschluss
M 10 Schrauben
Anschlussmöglichkeiten
Bis zu
Batterie / Batteriebank
1
Temperatur Sensor
2 –wiederstand, 1 –Spannung
Tank Sensor
2 –wiederstand, 1 –Spannung
This manual suits for next models
1
Table of contents
Languages:
Popular Control System manuals by other brands

Elkron
Elkron ELR600RT/10 manual

DoorKing
DoorKing 1625 installation manual

Melink
Melink Intelli-Hood installation manual

Whelen Engineering Company
Whelen Engineering Company PCCS9R installation guide

Beninca
Beninca VE.400 Operating instructions and spare parts catalogue

DEEP SEA ELECTRONICS
DEEP SEA ELECTRONICS DSEE400 installation instructions